In vivo diffusion tensor MRI of the human heart: Reproducibility of breath-hold and navigator-based approaches

被引:129
|
作者
Nielles-Vallespin, Sonia [1 ,2 ]
Mekkaoui, Choukri [3 ]
Gatehouse, Peter [1 ,2 ]
Reese, Timothy G. [3 ]
Keegan, Jennifer [1 ,2 ]
Ferreira, Pedro F. [1 ,2 ]
Collins, Steve [1 ]
Speier, Peter [4 ]
Feiweier, Thorsten [4 ]
de Silva, Ranil [1 ,2 ]
Jackowski, Marcel P. [5 ]
Pennell, Dudley J. [1 ,2 ]
Sosnovik, David E. [3 ]
Firmin, David [1 ,2 ]
机构
[1] Royal Brompton & Harefield NHS Fdn Trust, Cardiovasc MR Unit, London, England
[2] Univ London Imperial Coll Sci Technol & Med, London SW7 2AZ, England
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Martinos Ctr Biomed Imaging, Boston, MA USA
[4] Siemens AG, Healthcare Sect, MR R&D, Erlangen, Germany
[5] Univ Sao Paulo, Inst Math & Stat, Sao Paulo, Brazil
基金
美国国家卫生研究院;
关键词
cardiovascular magnetic resonance imaging; prospective navigators; cardiac diffusion tensor imaging; cardiac diffusion-weighted imaging; RESONANCE CORONARY-ANGIOGRAPHY; CARDIAC FIBER ARCHITECTURE; MYOCARDIAL BLOOD-VOLUME; MAGNETIC-RESONANCE; HISTOLOGICAL VALIDATION; WATER DIFFUSION; LEFT-VENTRICLE; INFARCTION; MOTION; TRACTOGRAPHY;
D O I
10.1002/mrm.24488
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to implement a quantitative in vivo cardiac diffusion tensor imaging (DTI) technique that was robust, reproducible, and feasible to perform in patients with cardiovascular disease. A stimulated-echo single-shot echo-planar imaging (EPI) sequence with zonal excitation and parallel imaging was implemented, together with a novel modification of the prospective navigator (NAV) technique combined with a biofeedback mechanism. Ten volunteers were scanned on two different days, each time with both multiple breath-hold (MBH) and NAV multislice protocols. Fractional anisotropy (FA), mean diffusivity (MD), and helix angle (HA) fiber maps were created. Comparison of initial and repeat scans showed good reproducibility for both MBH and NAV techniques for FA (P > 0.22), MD (P > 0.15), and HA (P > 0.28). Comparison of MBH and NAV FA (FA(MBHday1) = 0.60 +/- 0.04, FA(NAVday1) = 0.60 +/- 0.03, P = 0.57) and MD (MDMBHday1 = 0.8 +/- 0.2 x 10(-3) mm(2)/s, MDNAVday1 = 0.9 +/- 0.2 x 10(-3) mm(2)/s, P = 0.07) values showed no significant differences, while HA values (HA(MBHday1Endo) = 22 +/- 10 degrees, HA(MBHday1Mid-Endo) = 20 +/- 6 degrees, HA(MBHday1Mid-Epi) = -1 +/- 6 degrees, HA(MBHday1Epi) = -17 +/- 6 degrees, HA(NAVday1Endo) = 7 +/- 7 degrees, HA(NAVday1Mid-Endo) = 13 +/- 8 degrees, HA(NAVday1Mid-Epi) = -2 +/- 7 degrees, HA(NAVday1Epi) = -14 +/- 6 degrees) were significantly different. The scan duration was 20% longer with the NAV approach. Currently, the MBH approach is the more robust in normal volunteers. While the NAV technique still requires resolution of some bulk motion sensitivity issues, these preliminary experiments show its potential for in vivo clinical cardiac diffusion tensor imaging and for delivering high-resolution in vivo 3D DTI tractography of the heart. Magn Reson Med 70:454-465, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:454 / 465
页数:12
相关论文
共 50 条
  • [1] In Vivo Diffusion Tensor MRI of the Human Heart: Reproducibility of Breath-Hold and Navigator Based Approaches (vol 70, pg 454, 2013)
    Nielles-Vallespin, Sonia
    Mekkaoui, Choukri
    Gatehouse, Peter
    Reese, Timothy G.
    Keegan, Jennifer
    Ferreira, Pedro F.
    Collins, Steve
    Speier, Peter
    Feiweier, Thorsten
    de Silva, Ranil
    Jackowski, Marcel P.
    Pennell, Dudley J.
    Sosnovik, David E.
    Firmin, David
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (02) : 599 - 599
  • [2] Improved navigator based diffusion tensor MRI of the human heart in vivo
    PF Ferreira
    S Nielles-Vallespin
    PD Gatehouse
    R de Silva
    J Keegan
    P Speier
    T Feiweier
    TG Reese
    TF Ismail
    A Scott
    C Mekkaoui
    DE Sosnovik
    D Firmin
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [3] Diffusion tensor MRI of the human heart In Vivo with a navigator based free breathing approach
    Sonia Nielles-Vallespin
    Choukri Mekkaoui
    Peter D Gatehouse
    Timothy G Reese
    Jennifer Keegan
    Steven Collins
    Peter Speier
    Thorsten Feiweier
    Marcel P Jackowski
    David E Sosnovik
    David N Firmin
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [4] Improving the accuracy of multi breath-hold diffusion tensor MRI tractography of the heart using dynamic motioncorrection
    Choukri Mekkaoui
    Sonia Nielles-Vallespin
    Marcel P Jackowski
    Peter D Gatehouse
    Dudley J Pennell
    David N Firmin
    David E Sosnovik
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [5] Navigator-based motion compensation for liver BOLD measurement with five-echo SAGE EPI and breath-hold task
    Zhang, Ke
    Triphan, Simon M. F.
    Wielpuetz, Mark O.
    Ziener, Christian H.
    Ladd, Mark E.
    Schlemmer, Heinz-Peter
    Kauczor, Hans-Ulrich
    Sedlaczek, Oliver
    Kurz, Felix T.
    NMR IN BIOMEDICINE, 2024, 37 (10)
  • [6] INTER-STUDY REPRODUCIBILITY OF STRAIN MEASURMENTS BY CARDIAC MRI: A COMPARISON OF FEATURE TRACKING, SINGLE BREATH-HOLD TAGGING AND MULTI BREATH-HOLD TAGGING
    Singh, A.
    Steadman, C. D.
    Khan, J. N.
    Nazir, S. A.
    McCann, G. P.
    HEART, 2013, 99
  • [7] Study on the Clinical Use of a Respiratory Navigator Combined with Breath-Hold for MRI- Guided Liver SBRT
    Yao, W. X.
    Hu, Q. X.
    Xu, L. L.
    Bai, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E740 - E740
  • [8] Accelerating Cardiac Diffusion Tensor Imaging With a U-Net Based Model: Toward Single Breath-Hold
    Ferreira, Pedro F.
    Banerjee, Arjun
    Scott, Andrew D.
    Khalique, Zohya
    Yang, Guang
    Rajakulasingam, Ramyah
    Dwornik, Maria
    De Silva, Ranil
    Pennell, Dudley J.
    Firmin, David N.
    Nielles-Vallespin, Sonia
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 56 (06) : 1691 - 1704
  • [9] Diffusion-Weighted MRI in the Assessment of Split Renal Function: Comparison of Navigator-Triggered Prospective Acquisition Correction and Breath-Hold Acquisition
    Li, Qinghai
    Wu, Xinying
    Qiu, Lingling
    Zhang, Peipei
    Zhang, Minming
    Yan, Fuhua
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (01) : 113 - 119
  • [10] Reproducibility of MR-based attenuation correction maps for PET/MRI: Variations with free breathing and breath-hold protocols
    Oen, S. K.
    Lassen, M. L.
    Rausch, I.
    Myrthue, M. O.
    Eikens, L.
    Beyer, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S77 - S77