In vivo diffusion tensor MRI of the human heart: Reproducibility of breath-hold and navigator-based approaches

被引:129
|
作者
Nielles-Vallespin, Sonia [1 ,2 ]
Mekkaoui, Choukri [3 ]
Gatehouse, Peter [1 ,2 ]
Reese, Timothy G. [3 ]
Keegan, Jennifer [1 ,2 ]
Ferreira, Pedro F. [1 ,2 ]
Collins, Steve [1 ]
Speier, Peter [4 ]
Feiweier, Thorsten [4 ]
de Silva, Ranil [1 ,2 ]
Jackowski, Marcel P. [5 ]
Pennell, Dudley J. [1 ,2 ]
Sosnovik, David E. [3 ]
Firmin, David [1 ,2 ]
机构
[1] Royal Brompton & Harefield NHS Fdn Trust, Cardiovasc MR Unit, London, England
[2] Univ London Imperial Coll Sci Technol & Med, London SW7 2AZ, England
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Martinos Ctr Biomed Imaging, Boston, MA USA
[4] Siemens AG, Healthcare Sect, MR R&D, Erlangen, Germany
[5] Univ Sao Paulo, Inst Math & Stat, Sao Paulo, Brazil
基金
美国国家卫生研究院;
关键词
cardiovascular magnetic resonance imaging; prospective navigators; cardiac diffusion tensor imaging; cardiac diffusion-weighted imaging; RESONANCE CORONARY-ANGIOGRAPHY; CARDIAC FIBER ARCHITECTURE; MYOCARDIAL BLOOD-VOLUME; MAGNETIC-RESONANCE; HISTOLOGICAL VALIDATION; WATER DIFFUSION; LEFT-VENTRICLE; INFARCTION; MOTION; TRACTOGRAPHY;
D O I
10.1002/mrm.24488
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to implement a quantitative in vivo cardiac diffusion tensor imaging (DTI) technique that was robust, reproducible, and feasible to perform in patients with cardiovascular disease. A stimulated-echo single-shot echo-planar imaging (EPI) sequence with zonal excitation and parallel imaging was implemented, together with a novel modification of the prospective navigator (NAV) technique combined with a biofeedback mechanism. Ten volunteers were scanned on two different days, each time with both multiple breath-hold (MBH) and NAV multislice protocols. Fractional anisotropy (FA), mean diffusivity (MD), and helix angle (HA) fiber maps were created. Comparison of initial and repeat scans showed good reproducibility for both MBH and NAV techniques for FA (P > 0.22), MD (P > 0.15), and HA (P > 0.28). Comparison of MBH and NAV FA (FA(MBHday1) = 0.60 +/- 0.04, FA(NAVday1) = 0.60 +/- 0.03, P = 0.57) and MD (MDMBHday1 = 0.8 +/- 0.2 x 10(-3) mm(2)/s, MDNAVday1 = 0.9 +/- 0.2 x 10(-3) mm(2)/s, P = 0.07) values showed no significant differences, while HA values (HA(MBHday1Endo) = 22 +/- 10 degrees, HA(MBHday1Mid-Endo) = 20 +/- 6 degrees, HA(MBHday1Mid-Epi) = -1 +/- 6 degrees, HA(MBHday1Epi) = -17 +/- 6 degrees, HA(NAVday1Endo) = 7 +/- 7 degrees, HA(NAVday1Mid-Endo) = 13 +/- 8 degrees, HA(NAVday1Mid-Epi) = -2 +/- 7 degrees, HA(NAVday1Epi) = -14 +/- 6 degrees) were significantly different. The scan duration was 20% longer with the NAV approach. Currently, the MBH approach is the more robust in normal volunteers. While the NAV technique still requires resolution of some bulk motion sensitivity issues, these preliminary experiments show its potential for in vivo clinical cardiac diffusion tensor imaging and for delivering high-resolution in vivo 3D DTI tractography of the heart. Magn Reson Med 70:454-465, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:454 / 465
页数:12
相关论文
共 50 条
  • [21] Analysis of residual coronary artery motion for breath hold and navigator approaches using real-time coronary MRI
    Fischer, RW
    Botnar, RM
    Nehrke, K
    Boesiger, P
    Manning, WJ
    Peters, DC
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) : 612 - 618
  • [22] Assessment of reproducibility and stability of different breath-hold maneuvres by dynamic MRI:: comparison between healthy adults and patients with pulmonary hypertension
    Plathow, C
    Ley, S
    Zaporozhan, J
    Schöbinger, M
    Gruenig, E
    Puderbach, M
    Eichinger, M
    Meinzer, HP
    Zuna, I
    Kauczor, HU
    EUROPEAN RADIOLOGY, 2006, 16 (01) : 173 - 179
  • [23] Assessment of reproducibility and stability of different breath-hold maneuvres by dynamic MRI: comparison between healthy adults and patients with pulmonary hypertension
    Christian Plathow
    Sebastian Ley
    Julia Zaporozhan
    Max Schöbinger
    Ekkehard Gruenig
    Michael Puderbach
    Monika Eichinger
    Hans-Peter Meinzer
    Ivan Zuna
    Hans-Ulrich Kauczor
    European Radiology, 2006, 16 : 173 - 179
  • [24] Liver Diffusion-weighted MR Imaging: Reproducibility Comparison of ADC Measurements Obtained with Multiple Breath-hold, Free-breathing, Respiratory-triggered, and Navigator-triggered Techniques
    Chen, Xin
    Qin, Lei
    Pan, Dan
    Huang, Yanqi
    Yan, Lifen
    Wang, Guangyi
    Liu, Yubao
    Liang, Changhong
    Liu, Zaiyi
    RADIOLOGY, 2014, 271 (01) : 113 - 125
  • [25] Towards in vivo diffusion tensor MRI on human heart using edge-preserving regularization
    Frindel, Carole
    Robini, Marc
    Rapacchi, Stanislas
    Stephant, Eric
    Zhu, Yue-Min
    Croisille, Pierre
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 6008 - 6011
  • [26] Diffusion Tensor MRI of the Heart - In Vivo Imaging of Myocardial Fiber Architecture
    Froeling M.
    Strijkers G.J.
    Nederveen A.J.
    Chamuleau S.A.
    Luijten P.R.
    Current Cardiovascular Imaging Reports, 2014, 7 (7) : 1 - 11
  • [27] Magnetic resonance coronary anglography with vasovist™:: in-vivo T1 estimation to improve image quality of navigator and breath-hold techniques
    Nassenstein, Kai
    Waltering, Kai-Uwe
    Kelle, Sebastian
    Schlosser, Thomas
    Breuckmann, Frank
    Maderwald, Stefan
    Hunold, Peter
    Nagel, Eike
    Barkhausen, Joerg
    EUROPEAN RADIOLOGY, 2008, 18 (01) : 103 - 109
  • [28] Magnetic resonance coronary angiography with vasovist™: in-vivo T1 estimation to improve image quality of navigator and breath-hold techniques
    Kai Nassenstein
    Kai-Uwe Waltering
    Sebastian Kelle
    Thomas Schlosser
    Frank Breuckmann
    Stefan Maderwald
    Peter Hunold
    Eike Nagel
    Jörg Barkhausen
    European Radiology, 2008, 18 : 103 - 109
  • [29] Static Breath-Hold MRI Based Measurement of Change in Pulmonary Function Following a Course of Radiation Therapy
    Ding, K.
    Cao, K.
    Du, K.
    Chen, Q.
    Ennis, D.
    Christensen, G.
    Reinhardt, J.
    Libby, B.
    Benedict, S.
    Sheng, K.
    MEDICAL PHYSICS, 2012, 39 (06) : 3697 - 3697
  • [30] Routine breath-hold gradient echo MRI-derived right ventricular mass, volumes and function: accuracy, reproducibility and coherence study
    Farzin Beygui
    Alain Furber
    Stéphane Delépine
    Gérard Helft
    Jean-Philippe Metzger
    Philippe Geslin
    Jean Jacques Le Jeune
    The International Journal of Cardiovascular Imaging, 2004, 20 : 509 - 516