Cardiac gated breath-hold black blood MRI of the coronary artery wall: An in vivo and ex vivo comparison

被引:8
|
作者
Worthley, SG [1 ]
Helft, G [1 ]
Fayad, ZA [1 ]
Fuster, V [1 ]
Rodriguez, OJ [1 ]
Zaman, AG [1 ]
Badimon, JJ [1 ]
机构
[1] Mt Sinai Sch Med, Zena & Michael A Wiener Cardiovasc Inst, Cardiovasc Biol Res Lab, New York, NY 10029 USA
来源
关键词
coronary; motion suppression; MRI;
D O I
10.1023/A:1010688122184
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: High resolution magnetic resonance (MR) imaging of the coronary artery wall in vivo has been limited by the cardiac and respiratory motion, flow artifacts as well as the relatively small size of the coronary arteries. We sought to validate in vivo black blood MR imaging of the coronary artery wall using a double inversion recovery fast spin echo MR imaging sequence with limited breath-holding and cardiac gating for suppression of motion artifacts by comparison with ex vivo MR imaging. Methods: Yorkshire albino swine (n = 6) were used in this study and coronary lesions were induced with balloon angioplasty. Four weeks after balloon injury of the coronary arteries MR imaging of the coronary artery lesions was performed. High resolution in vivo and ex vivo images of the coronary artery wall and lesions were obtained using a double inversion recovery fast spin echo sequence in a 1.5 T MR system. There was a statistically significant agreement (p < 0.0001) between measurements of vessel wall area (r = 0.87, slope = 0.87) and maximal wall thickness (r = 0.84, slope = 0.88) from in vivo and ex vivo MR images of the coronary arteries. The mean differences between in vivo and ex vivo measurements were 0.56 +/- 1.98 mm(2) for vessel wall area and 0.02 +/- 0.36 mm for maximal wall thickness. Conclusions: Using breath-holding and cardiac gating, it is possible to perform high resolution MR imaging of the coronary artery wall in vivo with good suppression of motion artifacts with a double inversion recovery fast spin echo black blood imaging sequence.
引用
收藏
页码:195 / 201
页数:7
相关论文
共 50 条
  • [31] Comparison of contrast-enhanced breath-hold and free-breathing respiratory-gated imaging in three-dimensional magnetic resonance coronary angiography
    Regenfus, M
    Ropers, D
    Achenbach, S
    Schlundt, C
    Kessler, W
    Laub, G
    Moshage, W
    Daniel, WG
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (07): : 725 - 730
  • [32] Quantification of coronary artery stenosis with high-resolution CT in comparison with histopathology in an ex vivo study
    Dettmer, Matthias
    Glaser-Gallion, Nicola
    Stolzmann, Paul
    Glaser-Gallion, Florian
    Fornaro, Juergen
    Feuchtner, Gudrun
    Jochum, Wolfram
    Alkadhi, Hatem
    Wildermuth, Simon
    Leschka, Sebastian
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (02) : 264 - 269
  • [33] Peak blood flow measurement of coronary sinus by cine phase contrast MR imagings: Comparison between breath-hold and respiratory compensation techniques
    Amano, Y
    Nakajima, M
    Kumazaki, T
    CLINICAL IMAGING, 2001, 25 (01) : 23 - 27
  • [34] Comparison of two-dimensional breath-hold coronary MR angiography, three-dimensional coronary MR angiography in navigator technique, and conventional coronary angiography in patients with coronary artery disease
    Lentschig, MG
    Hoeffgen, M
    Wichter, T
    Reimer, P
    Rummeny, EJ
    RADIOLOGY, 1998, 209P : 305 - 305
  • [35] Editorial for "Dynamic Glucose-Enhanced Imaging of the Liver Using Breath-Hold Black Blood Quantitative T1ρ MRI at 3.0T"
    Hussain, Shahid M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 59 (03) : 1110 - 1111
  • [36] Single breath-hold real-time Cine MR Imaging in patients with coronary artery disease at rest and during stress for detection of regional wall motion abnormalities
    Kramer, U
    Miller, S
    Fenchel, M
    Helber, U
    Stauder, NI
    Claussen, CD
    RADIOLOGY, 2002, 225 : 575 - 575
  • [37] Ex vivo blockade of endothelin-1 inhibits graft coronary artery disease in a rodent cardiac allograft model
    Yamaguchi, A
    Miniati, DN
    Hirata, K
    Hoyt, EG
    Robbins, RC
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2002, 21 (04): : 417 - 424
  • [38] Dynamic Coronary Blood Flow Velocity and Wall Shear Stress Estimation Using Ultrasound in an Ex Vivo Porcine Heart
    Kim, Saeyoung
    Jing, Bowen
    Lane, Brooks A.
    Tempestti, Jimena Martin
    Padala, Muralidhar
    Veneziani, Alessandro
    Lindsey, Brooks D.
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2024, 15 (01) : 65 - 76
  • [39] Dynamic Coronary Blood Flow Velocity and Wall Shear Stress Estimation Using Ultrasound in an Ex Vivo Porcine Heart
    Saeyoung Kim
    Bowen Jing
    Brooks A. Lane
    Jimena Martín Tempestti
    Muralidhar Padala
    Alessandro Veneziani
    Brooks D. Lindsey
    Cardiovascular Engineering and Technology, 2024, 15 : 65 - 76
  • [40] In-vivo dosimetry comparison of supraclavicular junction dose for breast and chest-wall patients with and without deep inspiration breath hold (DIBH)
    Mackonis, Elizabeth Ruth Claridge
    Estoesta, Reuben Patrick
    Carroll, Susan