Dependency of Cardiac Resynchronization Therapy on Myocardial Viability at the LV Lead Position

被引:34
|
作者
Becker, Michael
Zwicker, Christian
Kaminski, Markus
Napp, Andreas
Altiok, Ertunc
Ocklenburg, Christina [2 ]
Friedman, Zvi [3 ]
Adam, Dan [3 ]
Schauerte, Patrick
Marx, Nikolaus
Hoffmann, Rainer [1 ]
机构
[1] Rhein Westfal TH Aachen, Med Clin 1, Dept Cardiol, D-52057 Aachen, Germany
[2] Rhein Westfal TH Aachen, Dept Med Stat, D-52057 Aachen, Germany
[3] Technion Israel Inst Technol, Dept Biomed Engn, IL-32000 Haifa, Israel
关键词
resynchronization therapy; echocardiography; heart failure; left ventricular function; myocardial deformation imaging; CHRONIC HEART-FAILURE; 2-DIMENSIONAL STRAIN; LONGITUDINAL STRAIN; SCAR TISSUE; IMPROVEMENT; PREDICTORS; STIMULATION; MORBIDITY; MORTALITY; IMPACT;
D O I
10.1016/j.jcmg.2011.01.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study sought to analyze the effectiveness of cardiac resynchronization therapy (CRT) related to the viability in the segment of left ventricular (LV) lead position defined by myocardial deformation imaging. BACKGROUND Echocardiographic myocardial deformation analysis allows determination of LV lead position as well as extent of myocardial viability. METHODS Myocardial deformation imaging based on tracking of acoustic markers within 2-dimensional echo images (GE Ultrasound, GE Healthcare, Horton, Norway) was performed in 65 heart failure patients (54 +/- 6 years of age, 41 men) before and 12 months after CRT implantation. In a 16-segment model, the LV lead position was defined based on the segmental strain curve with earliest peak strain, whereas the CRT system was programmed to pure LV pacing. Nonviability of a segment (transmural scar formation) was assumed if the peak systolic circumferential strain was >-11.1%. RESULTS In 47 patients, the LV lead was placed in a viable segment, and in 18 patients, it was placed in a nonviable segment. At 12-month follow-up there was greater decrease of LV end-diastolic volumes (58 +/- 13 ml vs. 44 +/- 12 ml, p = 0.0388) and greater increase of LV ejection fraction (11 +/- 4% vs. 5 +/- 4%, p = 0.0343) and peak oxygen consumption (2.5 +/- 0.9 ml/kg/min vs. 1.7 +/- 1.1 ml/kg/min, p = 0.0465) in the viable compared with the nonviable group. The change in LV ejection fraction and the reduction in LV end-diastolic volumes at follow-up correlated to an increasing peak systolic circumferential strain in the segment of the LV pacing lead (r = 0.61, p = 0.0274 and r = 0.64, p = 0.0412, respectively). Considering only patients with ischemic heart disease, differences between viable and nonviable LV lead position group were even greater. CONCLUSIONS Preserved viability in the segment of the CRT LV lead position results in greater LV reverse remodeling and functional benefit at 12-month follow-up. Deformation imaging allows analysis of viability in the LV lead segment. (J Am Coll Cardiol Img 2011;4:366-74) (C) 2011 by the American College of Cardiology Foundation
引用
收藏
页码:366 / 374
页数:9
相关论文
共 50 条
  • [41] 3D dynamic position assessment of the coronary sinus lead in cardiac resynchronization therapy
    Corsi, Cristiana
    Tomasi, Corrado
    Turco, Dario
    Margheri, Massimo
    Lamberti, Claudio
    Severi, Stefano
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2011, 49 (08) : 901 - 908
  • [42] ANALYSIS OF LEFT VENTRICULAR LEAD POSITION IN CARDIAC RESYNCHRONIZATION THERAPY USING DIFFERENT IMAGING MODALITIES
    Becker, Michael
    Altiok, Ertunc
    Hoffmann, Renate
    Schauerte, Patrick
    Koch, Christian
    Hoffmann, Rainer
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [43] 3D dynamic position assessment of the coronary sinus lead in cardiac resynchronization therapy
    Cristiana Corsi
    Corrado Tomasi
    Dario Turco
    Massimo Margheri
    Claudio Lamberti
    Stefano Severi
    Medical & Biological Engineering & Computing, 2011, 49 : 901 - 908
  • [44] Long-term super-response to cardiac resynchronization therapy by stimulation with fusion in HF patients with normal AV conduction and concordant LV lead position
    Vatasescu, R. -G.
    Iorgulescu, C.
    Vasile, A.
    Constantinescu, D.
    Dumitrescu, N.
    Dorobantu, M.
    EUROPEAN HEART JOURNAL, 2008, 29 : 414 - 414
  • [45] Cardiac resynchronization failures: The lateral chest X ray identifies patients who benefit from a new LV lead position
    Worley, SJ
    Gohn, DC
    Smith, TM
    JOURNAL OF CARDIAC FAILURE, 2004, 10 (04) : S118 - S118
  • [46] Cardiac resynchronization therapy in patients with a narrow QRS and evidence of LV dyssynchrony
    Taborsky, M.
    Neuzil, P.
    Schejbalova, M.
    EUROPEAN JOURNAL OF HEART FAILURE, 2007, 6 : 170 - 170
  • [47] Viability predicts response to cardiac resynchronization therapy in ischemic cardiomyopathy
    Ypenburg, C.
    Schalij, M. J.
    Bleeker, G. B.
    Steendijk, P.
    Dibbets-Schneider, P.
    Stokkel, M. P. M.
    Van Der Wall, E. E.
    Bax, J. J.
    EUROPEAN HEART JOURNAL, 2006, 27 : 175 - 175
  • [48] Septal function and viability determine response to cardiac resynchronization therapy
    Aalen, J.
    Donal, E.
    Larsen, C. K.
    Duchenne, J.
    Kongsgaard, E.
    Hopp, E.
    Penicka, M.
    Galli, E.
    Voigt, J. U.
    Smiseth, O. A.
    EUROPEAN HEART JOURNAL, 2019, 40 : 213 - 213
  • [49] Minithoracotomy as a primary alternative for LV lead implantation during coronary resynchronization therapy
    S Putnik
    N Aleksic
    M Matkovic
    A Mikic
    M Velinovic
    VZ Jovicic
    I Bilbija
    F Vucicevic
    D Ivanisevic
    M Ristic
    Journal of Cardiothoracic Surgery, 8 (Suppl 1)
  • [50] Comparing LV lead performance and procedure-related complications: transvenous vs epicardial leads in cardiac resynchronization therapy
    Tinoco, M. Mariana
    Castro, M.
    Pinheiro, L.
    Mata, E.
    Pereira, T.
    Calvo, L.
    Ribeiro, S.
    Almeida, F.
    Cardoso, F.
    Faria, B.
    Mendes, C.
    Rodrigues, B.
    Monteiro, V.
    Sanfins, V.
    Lourenco, A.
    EUROPEAN JOURNAL OF HEART FAILURE, 2024, 26 : 29 - 30