Portable Photoacoustic Sensor for Noninvasive Glucose Monitoring

被引:2
|
作者
Zhang, Ruochong [1 ]
Tang, Kai [1 ]
Yang, Chuanshi [1 ]
Jin, Haoran [1 ]
Liu, Siyu [1 ]
Zheng, Yuanjin [1 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore, Singapore
关键词
portable photoacoustic sensor; noninvasive glucose monitoring; near-infrared; Diabetes Mellitus;
D O I
10.1109/iscas.2019.8702322
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Diabetes mellitus is a prevalent metabolic disease which requires daily glucose monitoring for patients. Commercially available devices are all finger-prick which is painful and costly. Herein, we developed a portable and noninvasive glucose sensor based on photoacoustic (PA) technique. The size of the sensor main body is 17cm(L) x 14cm(W) x 10cm(H) with a weight of 650g (including a power bank). The system configuration is shown and the performance was evaluated by in vitro experiment on aqueous glucose solution at both high (1 similar to 8g/dL) and low concentrations (50 similar to 350 mg/dL). The R-2 and RMSE values achieved are 0.9526, 0.5903g/dL and 0.8966, 40.18mg/dL, respectively. Moreover, Clarke Error Grid analysis is also applied for physiological concentration prediction evaluation and 71.43% of data points fall in region A and the remaining points are in B, indicating the potential of our portable PA glucose sensor for clinical application.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Optical Methods for Noninvasive Blood Glucose Monitoring
    N. A. Bazaev
    Yu. P. Masloboev
    S. V. Selishchev
    [J]. Biomedical Engineering, 2012, 45 (6) : 229 - 233
  • [42] Noninvasive glucose monitoring - Comprehensive clinical results
    Tamada, JA
    Garg, S
    Jovanovic, L
    Pitzer, KR
    Fermi, S
    Potts, RO
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 282 (19): : 1839 - 1844
  • [43] Noninvasive Glucose Monitoring with a Contact Lens and Smartphone
    Lin, You-Rong
    Hung, Chin-Chi
    Chiu, Hsien-Yi
    Chang, Po-Han
    Li, Bor-Ran
    Cheng, Sheng-Jen
    Yang, Jia-Wei
    Lin, Shien-Fong
    Chen, Guan-Yu
    [J]. SENSORS, 2018, 18 (10)
  • [44] Noninvasive ultrasound glucose monitoring and insulin delivery
    Barrie-Smith, N
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U1221 - U1222
  • [45] QC test for noninvasive glucose monitoring system
    Wu, C
    Kersten, B
    Chen, Q
    Li, J
    Jagasia, P
    [J]. ELECTROANALYSIS, 2001, 13 (02) : 117 - 122
  • [46] Noninvasive Monitoring of Blood Glucose with Raman Spectroscopy
    Pandey, Rishikesh
    Paidi, Santosh Kumar
    Valdez, Tulio A.
    Zhang, Chi
    Spegazzini, Nicolas
    Dasari, Ramachandra Rao
    Barman, Ishan
    [J]. ACCOUNTS OF CHEMICAL RESEARCH, 2017, 50 (02) : 264 - 272
  • [47] Review of Noninvasive Continuous Glucose Monitoring in Diabetics
    Li, Yilin
    Chen, Yueyue
    [J]. ACS SENSORS, 2023, 8 (10) : 3659 - 3679
  • [48] Calcium-Sensitive Photoacoustic Probe for Noninvasive Extracellular Calcium Monitoring
    DeLuna, Frank
    McMahon, Nicholas
    Collot, Mayeul
    Ye, Jing Yong
    [J]. PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2020, 2020, 11240
  • [49] PORTABLE DOSIMETER WITH MOSFET SENSOR FOR RADIOTHERAPY MONITORING
    Carvajal, M. A.
    Banqueri, J.
    Palma, A. J.
    Lallena, A. M.
    Guirado, D.
    Vilches, M.
    [J]. BIODEVICES 2011, 2011, : 23 - +
  • [50] A Portable Optical Sensor for Sea Quality Monitoring
    Attivissimo, Filippo
    Carducci, Carlo Guarnieri Calo
    Lanzolla, Anna Maria Lucia
    Massaro, Alessandro
    Vadrucci, Maria Rosaria
    [J]. IEEE SENSORS JOURNAL, 2015, 15 (01) : 146 - 153