QC test for noninvasive glucose monitoring system

被引:0
|
作者
Wu, C [1 ]
Kersten, B [1 ]
Chen, Q [1 ]
Li, J [1 ]
Jagasia, P [1 ]
机构
[1] Cygnus Inc, Redwood City, CA 94063 USA
关键词
quality control test; noninvasive glucose monitoring system; GlucoWatch biographer; AutoSensor;
D O I
10.1002/1521-4109(200102)13:2<117::AID-ELAN117>3.0.CO;2-N
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A test kit for resting the efficacy of an iontophoretic sampling system of an automatic, noninvasive and frequent glucose monitoring system, GlucoWatch (Cygnus, Inc., Redwood City, CA) biographer, is described in this article. In this novel test kit; the iontophoretic sampling system has first and second surfaces. The first surface has a reservoir containing an ionic conductive medium, as well as enzyme capable of reacting with glucose to produce hydrogen peroxide. This enzymatically produced hydrogen peroxide is consequently electrochemically determined by a Pt-graphite electrode. Platinum in the platinum-graphite catalyzes the oxidation of hydrogen peroxide. Therefore, the amperometric signal is proportional to the concentration of glucose. The electrochemical response has been shown to correlate with the performance of the noninvasive iontophoresis glucose monitoring system as determined in clinical studies using thermally degraded AutoSensors. The test kit has been validated and proven to be specific, linear, precise, and stability indicating. This quality control (QC) test kit is a reliable testing tool for evaluating the performance of the GlucoWatch biographer and AutoSensor.
引用
收藏
页码:117 / 122
页数:6
相关论文
共 50 条
  • [1] Noninvasive glucose monitoring
    Thomas, A.
    Heinemann, L.
    [J]. DIABETOLOGE, 2014, 10 (01): : 36 - 42
  • [2] Towards Design and Development of Noninvasive Glucose Monitoring System
    Faris, Muhammad
    Ansari, Tayyab Ahmad
    Javid, Tariq
    Haseeb, Abdul
    Mujib, Muhammad Danish
    [J]. 2017 INTERNATIONAL CONFERENCE ON INNOVATIONS IN ELECTRICAL ENGINEERING AND COMPUTATIONAL TECHNOLOGIES (ICIEECT), 2017,
  • [3] Implantable Glucose Monitoring System in Test
    Klein, Friederike
    [J]. DIABETOLOGIE UND STOFFWECHSEL, 2017, 12 (02) : 108 - 108
  • [4] Noninvasive blood glucose monitoring
    Klonoff, DC
    [J]. DIABETES CARE, 1997, 20 (03) : 433 - 437
  • [5] The Quest for Noninvasive Glucose Monitoring
    Kim, Meeri
    [J]. Optics and Photonics News, 2022, 33 (10): : 30 - 38
  • [6] Design and In Vitro Interference Test of Microwave Noninvasive Blood Glucose Monitoring Sensor
    Choi, Heungjae
    Naylon, Jack
    Luzio, Steve
    Beutler, Jan
    Birchall, James
    Martin, Chris
    Porch, Adrian
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2015, 63 (10) : 3016 - 3025
  • [7] Measurement Accuracy of a Newly Developed Prototype System for Noninvasive Glucose Monitoring
    Freckmann, Guido
    Pleus, Stefan
    Wintergerst, Peter
    Waldenmaier, Delia
    Jendrike, Nina R.
    Link, Manuela
    Haug, Cornelia
    [J]. DIABETES, 2019, 68
  • [8] Development of a Noninvasive Blood Glucose Monitoring System Prototype: Pilot Study
    Valero, Maria
    Pola, Priyanka
    Falaiye, Oluwaseyi
    Ingram, Katherine H.
    Zhao, Liang
    Shahriar, Hossain
    Ahamed, Sheikh Iqbal
    [J]. JMIR FORMATIVE RESEARCH, 2022, 6 (08)
  • [9] GlucoScan: Noninvasive Glucose Monitoring Device
    Kendell, Claire
    Watson, Amanda
    Lee, Insup
    Weimer, James
    [J]. 2022 IEEE/ACM CONFERENCE ON CONNECTED HEALTH: APPLICATIONS, SYSTEMS AND ENGINEERING TECHNOLOGIES (CHASE 2022), 2022, : 158 - 159
  • [10] Recent advances in noninvasive glucose monitoring
    So, Chi-Fuk
    Choi, Kup-Sze
    Wong, Thomas K. S.
    Chung, Joanne W. Y.
    [J]. MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2012, 5 : 45 - 52