Development of a Noninvasive Blood Glucose Monitoring System Prototype: Pilot Study

被引:2
|
作者
Valero, Maria [1 ]
Pola, Priyanka [1 ]
Falaiye, Oluwaseyi [2 ]
Ingram, Katherine H. [3 ]
Zhao, Liang [1 ]
Shahriar, Hossain [1 ]
Ahamed, Sheikh Iqbal [4 ]
机构
[1] Kennesaw State Univ, Dept Informat Technol, 680 Arntson Dr,Suite J312, Marietta, GA 30060 USA
[2] Kennesaw State Univ, Dept Software Engn & Game Dev, Marietta, GA 30060 USA
[3] Kennesaw State Univ, Dept Exercise Sci & Sport Management, Kennesaw, GA 30144 USA
[4] Marquette Univ, Dept Comp Sci, Milwaukee, WI 53233 USA
关键词
diabetes; deep learning; machine learning; glucose concentration; noninvasive monitoring; optical sensors; glucose monitoring; SPECTROSCOPY;
D O I
10.2196/38664
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Diabetes mellitus is a severe disease characterized by high blood glucose levels resulting from dysregulation of the hormone insulin. Diabetes is managed through physical activity and dietary modification and requires careful monitoring of blood glucose concentration. Blood glucose concentration is typically monitored throughout the day by analyzing a sample of blood drawn from a finger prick using a commercially available glucometer. However, this process is invasive and painful, and leads to a risk of infection. Therefore, there is an urgent need for noninvasive, inexpensive, novel platforms for continuous blood sugar monitoring. Objective: Our study aimed to describe a pilot test to test the accuracy of a noninvasive glucose monitoring prototype that uses laser technology based on near-infrared spectroscopy. Methods: Our system is based on Raspberry Pi, a portable camera (Raspberry Pi camera), and a visible light laser. The Raspberry Pi camera captures a set of images when a visible light laser passes through skin tissue. The glucose concentration is estimated by an artificial neural network model using the absorption and scattering of light in the skin tissue. This prototype was developed using TensorFlow, Keras, and Python code. A pilot study was run with 8 volunteers that used the prototype on their fingers and ears. Blood glucose values obtained by the prototype were compared with commercially available glucometers to estimate accuracy. Results: When using images from the finger, the accuracy of the prototype is 79%. Taken from the ear, the accuracy is attenuated to 62%. Though the current data set is limited, these results are encouraging. However, three main limitations need to be addressed in future studies of the prototype: (1) increase the size of the database to improve the robustness of the artificial neural network model; (2) analyze the impact of external factors such as skin color, skin thickness, and ambient temperature in the current prototype; and (3) improve the prototype enclosure to make it suitable for easy finger and ear placement. Conclusions: Our pilot study demonstrates that blood glucose concentration can be estimated using a small hardware prototype that uses infrared images of human tissue. Although more studies need to be conducted to overcome limitations, this pilot study shows that an affordable device can be used to avoid the use of blood and multiple finger pricks for blood glucose monitoring in the diabetic population.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Noninvasive blood glucose monitoring with optical coherence tomography - A pilot study in human subjects
    Larin, KV
    Eledrisi, MS
    Motamedi, M
    Esenaliev, RO
    [J]. DIABETES CARE, 2002, 25 (12) : 2263 - 2267
  • [2] Measurement Accuracy of a Newly Developed Prototype System for Noninvasive Glucose Monitoring
    Freckmann, Guido
    Pleus, Stefan
    Wintergerst, Peter
    Waldenmaier, Delia
    Jendrike, Nina R.
    Link, Manuela
    Haug, Cornelia
    [J]. DIABETES, 2019, 68
  • [3] Noninvasive blood glucose monitoring
    Klonoff, DC
    [J]. DIABETES CARE, 1997, 20 (03) : 433 - 437
  • [4] Towards Design and Development of Noninvasive Glucose Monitoring System
    Faris, Muhammad
    Ansari, Tayyab Ahmad
    Javid, Tariq
    Haseeb, Abdul
    Mujib, Muhammad Danish
    [J]. 2017 INTERNATIONAL CONFERENCE ON INNOVATIONS IN ELECTRICAL ENGINEERING AND COMPUTATIONAL TECHNOLOGIES (ICIEECT), 2017,
  • [5] A Single LED Photoplethysmography-based Noninvasive Glucose Monitoring Prototype System
    Hina, Aminah
    Nadeem, Hamza
    Saadeh, Wala
    [J]. 2019 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2019,
  • [6] Phantoms for Development of Microwave Sensors for Noninvasive Blood Glucose Monitoring
    Vrba, Jan
    Karch, Jakub
    Vrba, David
    [J]. INTERNATIONAL JOURNAL OF ANTENNAS AND PROPAGATION, 2015, 2015
  • [7] Optical Based Noninvasive Glucose Monitoring Sensor Prototype
    Haxha, Shyqyri
    Jhoja, Jaspreet
    [J]. IEEE PHOTONICS JOURNAL, 2016, 8 (06):
  • [8] Effects of optical clearing agents on noninvasive blood glucose monitoring with optical coherence tomography: a pilot study
    He, Ruoyu
    Wei, Huajiang
    Gu, Huimin
    Zhu, Zhengguo
    Zhang, Yuqing
    Guo, Xiao
    Cai, Tiantian
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (10)
  • [9] Noninvasive blood glucose monitoring using the optical signal of pulsatile microcirculation: a pilot study in subjects with diabetes
    Chen, Chung-Sen
    Wang, Kuang-Kuo
    Jan, Ming-Yie
    Hsu, Wei-Chen
    Li, Sal-Ping
    Wang-Lin, Yuh-Ying
    Bau, Jian-Guo
    [J]. JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2008, 22 (06) : 371 - 376
  • [10] The Development of Acoustic System for Noninvasive Monitoring of Blood Perfusion
    Chua, Hui Ling
    Huong, Audrey
    Tay, Kim Gaik
    [J]. ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING: FROM THEORY TO APPLICATIONS, SERIES 2, 2019, 2173