Noninvasive blood glucose monitoring using the optical signal of pulsatile microcirculation: a pilot study in subjects with diabetes

被引:6
|
作者
Chen, Chung-Sen [2 ]
Wang, Kuang-Kuo [3 ]
Jan, Ming-Yie
Hsu, Wei-Chen [2 ]
Li, Sal-Ping
Wang-Lin, Yuh-Ying [4 ]
Bau, Jian-Guo [1 ,4 ]
机构
[1] Acad Sinica, Inst Phys, Biophys Lab, Taipei 115, Taiwan
[2] Taipei City Hosp, Zhongxiao Branch, Taipei 115, Taiwan
[3] Cheng Hsin Rehabil Med Ctr, Taipei 112, Taiwan
[4] Natl Taiwan Normal Univ, Inst Phys, Taipei 106, Taiwan
关键词
Noninvasive monitoring; SMBG; Microcirculation monitoring; Early diagnosis of complications;
D O I
10.1016/j.jdiacomp.2007.03.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The objective of this study was to determine the conditions for optimizing measurements obtained with a noninvasive blood glucose monitor using the optical signal of pulsatile microcirculation (OSPM) in both prediabetic and diabetic subjects receiving medication. Research Design and Methods: Eighteen subjects (3 prediabetic, 15 diabetic) aged 61.8 [15.9] years (mean [S.D.]) were studied. OSPM was the pulsatile component (P) of the signal obtained and analyzed by a blood glucose monitor. The measurement was calibrated to the fingerstick meter for each subject for personal calibration. Data were obtained from all subjects using both meters. Results: A total of 179 data pairs were measured and analyzed. The validity of the position of the tested finger was assessed using the position criterion, which resulted in the removal of 38 data pairs. The criterion for the intensity of the P signal was satisfied by 141 data pairs, with nonconforming data (with a much lower P signal) mainly occurring below 26 degrees C. A total of 113 data points passed both criteria, and 100% of them fell within Zones A and B of the Clarke error grid. Data in Zones A and B exhibited a linear relationship (r=.81; slope=0.82; intercept=28.0) between noninvasive and fingerstick measurements. Conclusions: Environmental temperature has the greatest influence on the capability of the OSPM technique to monitoring blood glucose concentration, which is subject dependent. The position of the tested finger is the second major factor, hence a carefully designed finger adaptor is essential. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:371 / 376
页数:6
相关论文
共 50 条
  • [1] Noninvasive blood glucose monitoring with optical coherence tomography - A pilot study in human subjects
    Larin, KV
    Eledrisi, MS
    Motamedi, M
    Esenaliev, RO
    [J]. DIABETES CARE, 2002, 25 (12) : 2263 - 2267
  • [2] Effects of optical clearing agents on noninvasive blood glucose monitoring with optical coherence tomography: a pilot study
    He, Ruoyu
    Wei, Huajiang
    Gu, Huimin
    Zhu, Zhengguo
    Zhang, Yuqing
    Guo, Xiao
    Cai, Tiantian
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (10)
  • [3] Development of a Noninvasive Blood Glucose Monitoring System Prototype: Pilot Study
    Valero, Maria
    Pola, Priyanka
    Falaiye, Oluwaseyi
    Ingram, Katherine H.
    Zhao, Liang
    Shahriar, Hossain
    Ahamed, Sheikh Iqbal
    [J]. JMIR FORMATIVE RESEARCH, 2022, 6 (08)
  • [4] Optical Methods for Noninvasive Blood Glucose Monitoring
    N. A. Bazaev
    Yu. P. Masloboev
    S. V. Selishchev
    [J]. Biomedical Engineering, 2012, 45 (6) : 229 - 233
  • [5] Specificity of noninvasive blood glucose sensing using optical coherence tomography technique: a pilot study
    Larin, KV
    Motamedi, M
    Ashitkov, TV
    Esenaliev, RO
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (10): : 1371 - 1390
  • [6] The studies of noninvasive blood glucose monitoring using optical coherence tomography
    Li Ran
    Liu Guozhong
    Hu Zhixiong
    Xia Xiaopeng
    Liu Tao
    [J]. 9TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES (AOMATT 2018): OPTICAL TEST, MEASUREMENT TECHNOLOGY, AND EQUIPMENT, 2019, 10839
  • [7] Blood glucose monitoring in human subjects using optical coherence tomography
    Jitendra Solanki
    Pratima Sen
    Joseph Thomas Andrews
    Kamal Kishore Thareja
    [J]. Journal of Optics, 2012, 41 (3) : 127 - 133
  • [8] Blood glucose monitoring in human subjects using optical coherence tomography
    Solanki, Jitendra
    Sen, Pratima
    Andrews, Joseph Thomas
    Thareja, Kamal Kishore
    [J]. JOURNAL OF OPTICS-INDIA, 2012, 41 (03): : 127 - 133
  • [9] Specificity of noninvasive blood glucose monitoring with optical coherence tomography
    Larin, KV
    Ashitkov, TV
    Motamedi, M
    Esenaliev, RO
    [J]. OPTICAL DIAGNOSTICS AND SENSING IN BIOMEDICINE III, 2003, 4965 : 25 - 31
  • [10] Monitoring of glucose levels in mouse blood with noninvasive optical methods
    Ullah, H.
    Ahmed, E.
    Ikram, M.
    [J]. LASER PHYSICS, 2014, 24 (02)