Development of a Noninvasive Blood Glucose Monitoring System Prototype: Pilot Study

被引:2
|
作者
Valero, Maria [1 ]
Pola, Priyanka [1 ]
Falaiye, Oluwaseyi [2 ]
Ingram, Katherine H. [3 ]
Zhao, Liang [1 ]
Shahriar, Hossain [1 ]
Ahamed, Sheikh Iqbal [4 ]
机构
[1] Kennesaw State Univ, Dept Informat Technol, 680 Arntson Dr,Suite J312, Marietta, GA 30060 USA
[2] Kennesaw State Univ, Dept Software Engn & Game Dev, Marietta, GA 30060 USA
[3] Kennesaw State Univ, Dept Exercise Sci & Sport Management, Kennesaw, GA 30144 USA
[4] Marquette Univ, Dept Comp Sci, Milwaukee, WI 53233 USA
关键词
diabetes; deep learning; machine learning; glucose concentration; noninvasive monitoring; optical sensors; glucose monitoring; SPECTROSCOPY;
D O I
10.2196/38664
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Diabetes mellitus is a severe disease characterized by high blood glucose levels resulting from dysregulation of the hormone insulin. Diabetes is managed through physical activity and dietary modification and requires careful monitoring of blood glucose concentration. Blood glucose concentration is typically monitored throughout the day by analyzing a sample of blood drawn from a finger prick using a commercially available glucometer. However, this process is invasive and painful, and leads to a risk of infection. Therefore, there is an urgent need for noninvasive, inexpensive, novel platforms for continuous blood sugar monitoring. Objective: Our study aimed to describe a pilot test to test the accuracy of a noninvasive glucose monitoring prototype that uses laser technology based on near-infrared spectroscopy. Methods: Our system is based on Raspberry Pi, a portable camera (Raspberry Pi camera), and a visible light laser. The Raspberry Pi camera captures a set of images when a visible light laser passes through skin tissue. The glucose concentration is estimated by an artificial neural network model using the absorption and scattering of light in the skin tissue. This prototype was developed using TensorFlow, Keras, and Python code. A pilot study was run with 8 volunteers that used the prototype on their fingers and ears. Blood glucose values obtained by the prototype were compared with commercially available glucometers to estimate accuracy. Results: When using images from the finger, the accuracy of the prototype is 79%. Taken from the ear, the accuracy is attenuated to 62%. Though the current data set is limited, these results are encouraging. However, three main limitations need to be addressed in future studies of the prototype: (1) increase the size of the database to improve the robustness of the artificial neural network model; (2) analyze the impact of external factors such as skin color, skin thickness, and ambient temperature in the current prototype; and (3) improve the prototype enclosure to make it suitable for easy finger and ear placement. Conclusions: Our pilot study demonstrates that blood glucose concentration can be estimated using a small hardware prototype that uses infrared images of human tissue. Although more studies need to be conducted to overcome limitations, this pilot study shows that an affordable device can be used to avoid the use of blood and multiple finger pricks for blood glucose monitoring in the diabetic population.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] A Noninvasive Stroke Volume Monitoring for Early Detection of Minimal Blood Loss: A Pilot Study
    Epstein, Danny
    Guinzburg, Ariel
    Sharon, Saar
    Kiso, Shai
    Glick, Yuval
    Marcusohn, Erez
    Glass, Yehuda Daniel
    Miller, Asaf
    Minha, Sa'ar
    Furer, Ariel
    [J]. SHOCK, 2021, 55 (02): : 230 - 235
  • [32] REVERSE IONTOPHORESIS - DEVELOPMENT OF A NONINVASIVE APPROACH FOR GLUCOSE MONITORING
    RAO, G
    GLIKFELD, P
    GUY, RH
    [J]. PHARMACEUTICAL RESEARCH, 1993, 10 (12) : 1751 - 1755
  • [33] Noninvasive glucose monitoring
    Thomas, A.
    Heinemann, L.
    [J]. DIABETOLOGE, 2014, 10 (01): : 36 - 42
  • [34] Specificity of noninvasive blood glucose monitoring with optical coherence tomography
    Larin, KV
    Ashitkov, TV
    Motamedi, M
    Esenaliev, RO
    [J]. OPTICAL DIAGNOSTICS AND SENSING IN BIOMEDICINE III, 2003, 4965 : 25 - 31
  • [35] Specificity of noninvasive blood glucose sensing using optical coherence tomography technique: a pilot study
    Larin, KV
    Motamedi, M
    Ashitkov, TV
    Esenaliev, RO
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (10): : 1371 - 1390
  • [36] Body metabolism provides a foundation for noninvasive blood glucose monitoring
    Ko, JB
    Cho, OK
    Kim, YO
    Yasuda, K
    [J]. DIABETES CARE, 2004, 27 (05) : 1211 - 1212
  • [37] Cutaneous Blood Perfusion as a Perturbing Factor for Noninvasive Glucose Monitoring
    Caduff, Andreas
    Talary, Mark S.
    Zakharov, Pavel
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2010, 12 (01) : 1 - 9
  • [38] Monitoring of glucose levels in mouse blood with noninvasive optical methods
    Ullah, H.
    Ahmed, E.
    Ikram, M.
    [J]. LASER PHYSICS, 2014, 24 (02)
  • [39] Experimental Based Blood Glucose Monitoring with a Noninvasive Cylindrical Biosensor
    Rahayu Y.
    Nugraha W.N.
    Praludi T.
    Alaydrus M.
    Anhar
    Masdar H.
    [J]. Progress In Electromagnetics Research M, 2023, 115 : 71 - 81
  • [40] THE STRUCTURE OPTIMIZATION ABOUT NONINVASIVE BLOOD GLUCOSE MONITORING DEVICES
    Chen, N.
    Chen, Z. B.