Optimizing the frame duration for data-driven rigid motion estimation in brain PET imaging

被引:11
|
作者
Spangler-Bickell, Matthew G. [1 ,2 ]
Hurley, Samuel A. [1 ]
Deller, Timothy W. [2 ]
Jansen, Floris [2 ]
Bettinardi, Valentino [3 ]
Carlson, Mackenzie [4 ]
Zeineh, Michael [4 ]
Zaharchuk, Greg [4 ]
McMillan, Alan B. [1 ]
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[2] GE Healthcare, PET MR Engn, Waukesha, WI 53188 USA
[3] Nucl Med Unit, IRCCS Osped San Raffaele, Milan, Italy
[4] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
brain imaging; data-driven motion estimation; list-mode; PET reconstruction; rigid motion correction; ultrashort frames; HEAD MOTION; REGISTRATION; RECONSTRUCTION; PERFORMANCE; IMAGES;
D O I
10.1002/mp.14889
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Data-driven rigid motion estimation for PET brain imaging is usually performed using data frames sampled at low temporal resolution to reduce the overall computation time and to provide adequate signal-to-noise ratio in the frames. In recent work it has been demonstrated that list-mode reconstructions of ultrashort frames are sufficient for motion estimation and can be performed very quickly. In this work we take the approach of using image-based registration of reconstructions of very short frames for data-driven motion estimation, and optimize a number of reconstruction and registration parameters (frame duration, MLEM iterations, image pixel size, post-smoothing filter, reference image creation, and registration metric) to ensure accurate registrations while maximizing temporal resolution and minimizing total computation time. Methods: Data from F-18-fluorodeoxyglucose (FDG) and F-18-florbetaben (FBB) tracer studies with varying count rates are analyzed, for PET/MR and PET/CT scanners. For framed reconstructions using various parameter combinations interframe motion is simulated and image-based registrations are performed to estimate that motion. Results: For FDG and FBB tracers using 4 x 10(5) true and scattered coincidence events per frame ensures that 95% of the registrations will be accurate to within 1 mm of the ground truth. This corresponds to a frame duration of 0.5-1 sec for typical clinical PET activity levels. Using four MLEM iterations with no subsets, a transaxial pixel size of 4 mm, a post-smoothing filter with 4-6 mm full width at half maximum, and averaging two or more frames to create the reference image provides an optimal set of parameters to produce accurate registrations while keeping the reconstruction and processing time low. Conclusions: It is shown that very short frames (<= 1 sec) can be used to provide accurate and quick data-driven rigid motion estimates for use in an event-by-event motion corrected reconstruction. (C) 2021 American Association of Physicists in Medicine
引用
收藏
页码:3031 / 3041
页数:11
相关论文
共 50 条
  • [41] An evaluation of data-driven motion estimation in comparison to the usage of external-surrogates in cardiac SPECT imaging
    Mukherjee, Joyeeta Mitra
    Hutton, Brian F.
    Johnson, Karen L.
    Pretorius, P. Hendrik
    King, Michael A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (21): : 7625 - 7646
  • [42] Comparison of Data-driven and External-Surrogate Based Motion Estimation Strategies in Cardiac SPECT Imaging
    Mukherjee, Joyeeta Mitra
    Pretorius, P. Hendrik
    Johnson, Karen L.
    Hutton, Brian F.
    King, Michael A.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2987 - 2991
  • [43] Data-driven motion exaggeration
    Zhang, Xiang
    Liang, Xiubo
    Fan, Rukun
    Geng, Weidong
    Jisuanji Fuzhu Sheji Yu Tuxingxue Xuebao/Journal of Computer-Aided Design and Computer Graphics, 2010, 22 (09): : 1468 - 1474
  • [44] Rigid Motion Correction for Brain PET/MR Imaging Using Optical Tracking
    Spangler-Bickell, Matthew G.
    Khalighi, Mohammad Mehdi
    Hoo, Charlotte
    DiGiacomo, Phillip Scott
    Maclaren, Julian
    Aksoy, Murat
    Rettmann, Dan
    Bammer, Roland
    Zaharchuk, Greg
    Zeineh, Michael
    Jansen, Floris
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2019, 3 (04) : 498 - 503
  • [45] Prostate cancer imaging with PSMA PET/MRI: The effects of data-driven bulk patient motion and its compensation
    Bogdanovic, B.
    Solari, E.
    Asiares, A. Villagran
    Schachoff, S.
    Eiber, M.
    Weber, W.
    Nekolla, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S309 - S309
  • [46] Clinical utility of data-driven motion correction for amyloid brain PET using 18F-flutemetamol
    Park, Hye Lim
    Park, Sonya
    Kim, Mingeon
    Paeng, Soyeon
    Min, Eun Jeong
    Hong, Inki
    Jones, Judson
    Han, Eun Ji
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [47] Data-driven voluntary body motion detection and non-rigid event-by-event correction for static and dynamic PET
    Lu, Yihuan
    Gallezot, Jean-Dominique
    Naganawa, Mika
    Ren, Silin
    Fontaine, Kathryn
    Wu, Jing
    Onofrey, John A.
    Toyonaga, Takuya
    Boutagy, Nabil
    Mulnix, Tim
    Panini, Vladimir Y.
    Casey, Michael E.
    Carson, Richard E.
    Liu, Chi
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (06):
  • [48] A Data-driven Approach for Estimating the Spatial Resolution of Brain PET images
    Carbonell, Felix
    Zijdenbos, Alex
    Bedell, Barry
    NEUROLOGY, 2020, 94 (15)
  • [49] Evaluation of data-driven respiratory gating waveforms for clinical PET imaging
    Walker, Matthew D.
    Morgan, Andrew J.
    Bradley, Kevin M.
    McGowan, Daniel R.
    EJNMMI RESEARCH, 2019, 9 (1)
  • [50] Evaluation of data-driven respiratory gating waveforms for clinical PET imaging
    Matthew D. Walker
    Andrew J. Morgan
    Kevin M. Bradley
    Daniel R. McGowan
    EJNMMI Research, 9