Optimizing the frame duration for data-driven rigid motion estimation in brain PET imaging

被引:11
|
作者
Spangler-Bickell, Matthew G. [1 ,2 ]
Hurley, Samuel A. [1 ]
Deller, Timothy W. [2 ]
Jansen, Floris [2 ]
Bettinardi, Valentino [3 ]
Carlson, Mackenzie [4 ]
Zeineh, Michael [4 ]
Zaharchuk, Greg [4 ]
McMillan, Alan B. [1 ]
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[2] GE Healthcare, PET MR Engn, Waukesha, WI 53188 USA
[3] Nucl Med Unit, IRCCS Osped San Raffaele, Milan, Italy
[4] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
brain imaging; data-driven motion estimation; list-mode; PET reconstruction; rigid motion correction; ultrashort frames; HEAD MOTION; REGISTRATION; RECONSTRUCTION; PERFORMANCE; IMAGES;
D O I
10.1002/mp.14889
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Data-driven rigid motion estimation for PET brain imaging is usually performed using data frames sampled at low temporal resolution to reduce the overall computation time and to provide adequate signal-to-noise ratio in the frames. In recent work it has been demonstrated that list-mode reconstructions of ultrashort frames are sufficient for motion estimation and can be performed very quickly. In this work we take the approach of using image-based registration of reconstructions of very short frames for data-driven motion estimation, and optimize a number of reconstruction and registration parameters (frame duration, MLEM iterations, image pixel size, post-smoothing filter, reference image creation, and registration metric) to ensure accurate registrations while maximizing temporal resolution and minimizing total computation time. Methods: Data from F-18-fluorodeoxyglucose (FDG) and F-18-florbetaben (FBB) tracer studies with varying count rates are analyzed, for PET/MR and PET/CT scanners. For framed reconstructions using various parameter combinations interframe motion is simulated and image-based registrations are performed to estimate that motion. Results: For FDG and FBB tracers using 4 x 10(5) true and scattered coincidence events per frame ensures that 95% of the registrations will be accurate to within 1 mm of the ground truth. This corresponds to a frame duration of 0.5-1 sec for typical clinical PET activity levels. Using four MLEM iterations with no subsets, a transaxial pixel size of 4 mm, a post-smoothing filter with 4-6 mm full width at half maximum, and averaging two or more frames to create the reference image provides an optimal set of parameters to produce accurate registrations while keeping the reconstruction and processing time low. Conclusions: It is shown that very short frames (<= 1 sec) can be used to provide accurate and quick data-driven rigid motion estimates for use in an event-by-event motion corrected reconstruction. (C) 2021 American Association of Physicists in Medicine
引用
收藏
页码:3031 / 3041
页数:11
相关论文
共 50 条
  • [1] Optimizing the frame duration for data-driven rigid motion estimation in brain PET imaging (vol 48, pg 3031, 2021)
    Spangler-Bickella, Matthew G. G.
    Hurley, Samuel A. A.
    Deller, Timothy W. W.
    Jansen, Floris
    Bettinardi, Valentino
    Carlson, Mackenzie
    Zeineh, Michael
    Zaharchuk, Greg
    McMillan, Alan B. B.
    MEDICAL PHYSICS, 2023, 50 (08) : 5295 - 5295
  • [2] Data-driven patient motion estimation for PET brain imaging
    Mukherjee, Joyeeta
    Mukherjee, Amit
    Olivier, Patrick
    Song, Xiyun
    Shao, Lingxiong
    King, Michael
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [3] Evaluation of Data-Driven Rigid Motion Correction in Clinical Brain PET Imaging
    Spangler-Bickell, Matthew G.
    Hurley, Samuel A.
    Pirasteh, Ali
    Perlman, Scott B.
    Deller, Timothy
    McMillan, Alan B.
    JOURNAL OF NUCLEAR MEDICINE, 2022, 63 (10) : 1604 - 1610
  • [4] Verification of the effect of data-driven brain motion correction on PET imaging
    Odagiri, Hayato
    Watabe, Hiroshi
    Takanami, Kentaro
    Akimoto, Kazuma
    Usui, Akihito
    Kawakami, Hirofumi
    Katsuki, Akie
    Uetake, Nozomu
    Dendo, Yutaka
    Tanaka, Yoshitaka
    Kodama, Hiroyasu
    Takase, Kei
    Kaneta, Tomohiro
    PLOS ONE, 2024, 19 (07):
  • [5] Clinical Evaluation of Data-Driven Motion Corrected Reconstruction for PET Brain Imaging
    Spangler-Bickell, Matthew
    Hurley, Samuel
    Pirasteh, Ali
    Perlman, Scott
    Deller, Timothy
    McMillan, Alan
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62
  • [6] Data-driven rigid motion correction of PET brain images using list mode reconstruction
    Hurley, Samuel
    Spangler-Bickell, Matthew
    Deller, Timothy
    Bradshaw, Tyler
    Jansen, Floris
    McMillan, Alan
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [7] Real-Time Data-Driven Rigid Motion Detection and Correction for Brain Scan with Listmode PET
    Feng, Tao
    Yang, Defu
    Zhu, Wentao
    Dong, Yun
    Li, Hongdi
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [8] Clinical Evaluation of Data-driven Motion Correction for PET Imaging
    Uribe, C. F.
    Rousseau, E.
    Lacroix-Poisson, F.
    Alden, T.
    Wollenweber, S.
    Benard, F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S360 - S361
  • [9] Improving diagnostic precision in amyloid brain PET imaging through data-driven motion correction
    Park, Hye Lim
    Park, Sonya Youngju
    Kim, Mingeon
    Paeng, Soyeon
    Min, Eun Jeong
    Hong, Inki
    Jones, Judson
    Han, Eun Ji
    EJNMMI PHYSICS, 2024, 11 (01):
  • [10] Adaptive data-driven motion detection for optimized motion correction of brain PET
    Lu, Yihuan
    Revilla, Enette Mae
    Gallezot, Jean-Dominique
    Naganawa, Mika
    Toyonaga, Takuya
    Fontaine, Kathryn
    Mulnix, Tim
    Carson, Richard
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61