Non-invasive monitoring method for lower-leg compartment syndrome using a wireless sensor system and finite element analysis

被引:3
|
作者
Chang, Fuh-Yu [1 ]
Teng, Ping-Tun [1 ]
Chen, Liang-Chun [1 ]
机构
[1] Taiwan Univ Sci & Technol, Dept Mech Engn, 43,Sect 4,Keelung Rd, Taipei 106, Taiwan
关键词
Compartment syndrome; non-invasive pressure detect; pressure sensor; finite element method; smartphone;
D O I
10.1177/0954411920981243
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, a non-invasive pressure monitoring system that is portable and convenient was designed for detecting compartment syndrome. The system combines a wireless module and smartphone, which aids in the achievement of mHealth objectives, specifically, the continuous monitoring of the compartment pressure in patients. A compartment syndrome detecting method using a wireless sensor system and finite element analysis is developed and verified with an in vitro lower-leg model by rapid prototyping. The sensor system is designed to measure a five point pressure variation from the outside of the lower leg and transmit the data to a smartphone via Bluetooth. The analysis model based on the finite element method is employed to calculate the change of pressure and volume inside the four compartments of the lower leg. The in vitro experimental results show that the non-invasive detecting method can monitor the compartment pressure and provide a warning for the occurrence of compartment syndrome if the compartment pressure is higher than 30 mmHg. Furthermore, the theoretical simulation of the real lower leg shows similar trends to those of the in vitro experiments and can promptly detect the occurrence of compartment syndrome. Measured pressure values exceeding 6.3, 2.7, and 2.8 kPa for the three sensors contacting the outside centers of the superficial posterior, anterior, and lateral compartments, respectively, can indicate that each compartment contains a pressure higher than 30 mmHg. These results can provide a warning for the risk of compartment syndrome of each compartment. In addition, the measured values from the three sensors contacting the superficial posterior compartment at the outside center, close to the tibia, and close to the lateral compartment exceeding 1.8, 0.7, and 0.7 kPa, respectively, can indicate the risk of deep posterior compartment syndrome.
引用
收藏
页码:346 / 356
页数:11
相关论文
共 50 条
  • [31] Development of an electronic device with wireless interface for measuring and monitoring residential electrical loads using the non-invasive method
    André Araújo Kuhn Pereira
    Raimundo José Andrade Menezes
    Aydin Jadidi
    Pieter De Jong
    Antonio Cezar de Castro Lima
    Energy Efficiency, 2020, 13 : 1281 - 1298
  • [32] Development of an electronic device with wireless interface for measuring and monitoring residential electrical loads using the non-invasive method
    Kuhn Pereira, Andre Araujo
    Andrade Menezes, Raimundo Jose
    Jadidi, Aydin
    De Jong, Pieter
    de Castro Lima, Antonio Cezar
    ENERGY EFFICIENCY, 2020, 13 (07) : 1281 - 1298
  • [33] Non-invasive method for blood glucose monitoring using ECG signal
    Arbi, Khadidja Fellah
    Soulimane, Sofiane
    Saffih, Faycal
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2023, 29 (01): : 1 - 9
  • [34] WIRELESS MEASUREMENT SYSTEM FOR NON-INVASIVE BIOMEDICAL MONITORING OF PSYCHO-PHYSIOLOGICAL PROCESSES
    Majer, Libor
    Stopjakova, Viera
    Vavrinsky, Erik
    JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS, 2009, 60 (02): : 57 - 68
  • [35] Design of mine emergency rescue non-invasive wireless vital signs monitoring system
    Zhou, Xusheng
    Liu, Jingyong
    Huo, Yu
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 125 : 225 - 225
  • [36] Non-invasive Wireless Mobile System for COVID-19 Monitoring in Nursing Homes
    Botella-Campos, Marta
    Viciano-Tudela, Sandra
    Sendra, Sandra
    Lloret, Jaime
    PROCEEDINGS OF THE 17TH INTERNATIONAL JOINT CONFERENCE ON E-BUSINESS AND TELECOMMUNICATIONS (SECRYPT), VOL 1, 2020, : 7 - 16
  • [37] Non-invasive monitoring system of synchronous generator using external field
    Dos Santos H.F.
    Rigoni M.
    Elias R.D.A.
    Feler L.A.
    Wengerkievicz C.A.C.
    Batistela N.J.
    Sadowski N.
    Kuo-Peng P.
    Bastos J.P.A.
    De Freitas L.M.
    1600, Sociedade Brasileira de Microondas e Optoeletronica (SBMO) (16) : 70 - 89
  • [38] Developing a non-invasive monitoring system using near IR dyes
    Sepasizangabadi, Hamidreza
    Cooley, Nicholas
    Shao, Xiaole
    Glass, Timothy
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [39] A non-invasive method of glucose monitoring using FR4 material based microwave antenna sensor
    Nella, Anveshkumar
    Aldhaheri, Rabah Wasel
    Kamili, Jagadeesh Babu
    Sobahi, Nebras Mohammed
    SCIENCE AND ENGINEERING OF COMPOSITE MATERIALS, 2023, 30 (01)
  • [40] Optical Sensor System for Continuous Non-Invasive Hemodynamic Monitoring in Real-Time
    Timm, U.
    Andruschenko, S.
    Hinz, M.
    Koball, S.
    Leen, G.
    Lewis, E.
    Kraitl, J.
    Ewald, H.
    2011 IEEE SENSORS APPLICATIONS SYMPOSIUM (SAS), 2011, : 167 - 172