Long-length tomosynthesis and 3D-2D registration for intraoperative assessment of spine instrumentation

被引:11
|
作者
Zhang, Xiaoxuan [1 ]
Uneri, Ali [1 ]
Wu, Pengwei [1 ]
Ketcha, Michael Daniel [1 ]
Jones, Craig K. [2 ]
Huang, Yixuan [1 ]
Lo, Sheng-Fu Larry [3 ]
Helm, Patrick A. [4 ]
Siewerdsen, Jeffrey H. [1 ,2 ,3 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Dept Comp Sci, Baltimore, MD 21218 USA
[3] Johns Hopkins Univ, Dept Neurosurg, Baltimore, MD 21218 USA
[4] Medtronic, Littleton, MA USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2021年 / 66卷 / 05期
关键词
tomosynthesis; 3D-2D registration; image-guided surgery; intraoperative imaging; spine surgery; spinal alignment; PEDICLE SCREW PLACEMENT; COMPUTED-TOMOGRAPHY; IMAGE REGISTRATION; ACCURACY; SURGERY; RADIOGRAPHY; QUALITY; COMPLICATIONS; LOCALIZATION; SCOLIOSIS;
D O I
10.1088/1361-6560/abde96
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose. A system for long-length intraoperative imaging is reported based on longitudinal motion of an O-arm gantry featuring a multi-slot collimator. We assess the utility of long-length tomosynthesis and the geometric accuracy of 3D image registration for surgical guidance and evaluation of long spinal constructs. Methods. A multi-slot collimator with tilted apertures was integrated into an O-arm system for long-length imaging. The multi-slot projective geometry leads to slight view disparity in both long-length projection images (referred to as 'line scans') and tomosynthesis 'slot reconstructions' produced using a weighted-backprojection method. The radiation dose for long-length imaging was measured, and the utility of long-length, intraoperative tomosynthesis was evaluated in phantom and cadaver studies. Leveraging the depth resolution provided by parallax views, an algorithm for 3D-2D registration of the patient and surgical devices was adapted for registration with line scans and slot reconstructions. Registration performance using single-plane or dual-plane long-length images was evaluated and compared to registration accuracy achieved using standard dual-plane radiographs. Results. Longitudinal coverage of similar to 50-64 cm was achieved with a single long-length slot scan, providing a field-of-view (FOV) up to (40 x 64) cm(2), depending on patient positioning. The dose-area product (reference point air kerma x x-ray field area) for a slot scan ranged from similar to 702-1757 mGycm(2), equivalent to similar to 2.5 s of fluoroscopy and comparable to other long-length imaging systems. Long-length scanning produced high-resolution tomosynthesis reconstructions, covering similar to 12-16 vertebral levels. 3D image registration using dual-plane slot reconstructions achieved median target registration error (TRE) of 1.2 mm and 0.6 degrees in cadaver studies, outperforming registration to dual-plane line scans (TRE = 2.8 mm and 2.2 degrees) and radiographs (TRE = 2.5 mm and 1.1 degrees). 3D registration using single-plane slot reconstructions leveraged the similar to 7-14 degrees angular separation between slots to achieve median TRE similar to 2 mm and Conclusion. The multi-slot configuration provided intraoperative visualization of long spine segments, facilitating target localization, assessment of global spinal alignment, and evaluation of long surgical constructs. 3D-2D registration to long-length tomosynthesis reconstructions yielded a promising means of guidance and verification with accuracy exceeding that of 3D-2D registration to conventional radiographs.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] 3D-2D registration in mobile radiographs: algorithm development and preliminary clinical evaluation
    Otake, Yoshito
    Wang, Adam S.
    Uneri, Ali
    Kleinszig, Gerhard
    Vogt, Sebastian
    Aygun, Nafi
    Lo, Sheng-fu L.
    Wolinsky, Jean-Paul
    Gokaslan, Ziya L.
    Siewerdsen, Jeffrey H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (05): : 2075 - 2090
  • [32] Automated Multimodal Computer Aided Detection Based on a 3D-2D Image Registration
    Hopp, T.
    Neupane, B.
    Ruiter, N. V.
    BREAST IMAGING, IWDM 2016, 2016, 9699 : 400 - 407
  • [33] 3D-2D Registration of Cerebral Angiograms Based on Vessel Directions and Intensity Gradients
    Mitrovic, Uros
    Spiclin, Ziga
    Stern, Darko
    Markelj, Primoz
    Likar, Bostjan
    Milosevic, Zoran
    Pernus, Franjo
    MEDICAL IMAGING 2012: IMAGE PROCESSING, 2012, 8314
  • [34] 3D-2D Medical Image Registration Technology and Its Application Development: a Survey
    Xiao, Handan
    PROCEEDINGS OF 2023 4TH INTERNATIONAL SYMPOSIUM ON ARTIFICIAL INTELLIGENCE FOR MEDICINE SCIENCE, ISAIMS 2023, 2023, : 95 - 100
  • [35] A Hybrid 3D-2D Image Registration Framework for Pedicle Screw Trajectory Registration between Intraoperative X-ray Image and Preoperative CT Image
    Naik, Roshan Ramakrishna
    Hoblidar, Anitha
    Bhat, Shyamasunder N.
    Ampar, Nishanth
    Kundangar, Raghuraj
    JOURNAL OF IMAGING, 2022, 8 (07)
  • [36] Deformable 3D-2D registration for CT and its application to low dose tomographic fluoroscopy
    Flach, Barbara
    Brehm, Marcus
    Sawall, Stefan
    Kachelriess, Marc
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (24): : 7865 - 7887
  • [37] Evaluation of low-dose limits in 3D-2D rigid registration for surgical guidance
    Uneri, A.
    Wang, A. S.
    Otake, Y.
    Kleinszig, G.
    Vogt, S.
    Khanna, A. J.
    Gallia, G. L.
    Gokaslan, Z. L.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (18): : 5329 - 5345
  • [38] Efficient Similarity Measurement between Digitally Reconstructed Radiograph and Fluoroscopy for 3D-2D Registration
    Rao, Chaitanya R. H.
    Anitha, H.
    Bhat, Shyamasunder N.
    Bhat, Vidya
    2018 INTERNATIONAL CONFERENCE ON ADVANCES IN COMPUTING, COMMUNICATIONS AND INFORMATICS (ICACCI), 2018, : 611 - 616
  • [39] Correction of patient motion in cone-beam CT using 3D-2D registration
    Ouadah, S.
    Jacobson, M.
    Stayman, J. W.
    Ehtiati, T.
    Weiss, C.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (23): : 8813 - 8831
  • [40] Segmentation of X-ray Images by 3D-2D Registration Based on Multibody Physics
    Schmid, Jerome
    Chenes, Christophe
    COMPUTER VISION - ACCV 2014, PT II, 2015, 9004 : 674 - 687