Accuracy of S2 Alar-Iliac Screw Placement Under the Guidance of a 3D-Printed Surgical Guide Template

被引:5
|
作者
Zhao, Yonghui [1 ,2 ]
Luo, Haotian [1 ]
Ma, Yulong [2 ]
Liang, Jinlong [2 ]
Han, Gonghai [1 ]
Xu, Yongqing [2 ]
Lu, Sheng [1 ]
机构
[1] Kunming Univ Sci & Technol, Peoples Hosp Yunnan Prov 1, Dept Orthoped, Key Lab Digital Orthoped Yunnan Prov,Affiliated H, Kunming, Yunnan, Peoples R China
[2] 920 Hosp Joint Logist Support Force, Dept Orthoped, Kunming, Yunnan, Peoples R China
基金
中国国家自然科学基金;
关键词
3D printing technology; Accuracy; S2AI screw; Surgical guide template; MINIMUM 5-YEAR ANALYSIS; SACROPELVIC FIXATION; PELVIC FIXATION; LONG FUSIONS; SPINE; ADULT; SACRUM; COMPLICATIONS; S1;
D O I
10.1016/j.wneu.2020.10.063
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: To evaluate the safety and accuracy of S2 alar-iliac (S2AI) screw placement guided by a 3-dimensional (3D)-printed surgical guide template. - METHODS: The data of 27 patients treated with S2AI screws were analyzed. S2AI surgical guide templates were designed and printed, and S2AI screw placement was completed intraoperatively with the guide templates. Postoperative computed tomography was performed to measure screw path parameters, namely the sagittal angle (SA), the transverse angle (TA), the horizontal distance (HD) between the entry point of the screw and the median sacral crest, and the vertical distance (VD) between the entry point of the screw and the lower edge of the first posterior sacral foramen. Screw placement was graded according to the Oh grading criteria. RESULTS: A total of 54 S2AI screws were placed. The screw grades were as follows: 52 screws were considered grade 0, 2 were grade 1, none were grade 2, and none were grade 3. Thus grade 0 accounted for 96.3% of the screws. When the preoperatively planned SA (32.3 degrees +/- 2.0 degrees), TA (42.1 degrees +/- 3.9 degrees), HD (5.1 +/- 1.1) mm, and VD (19.0 +/- 2.4) mm were compared with the corresponding postoperative SA ( 31.9 degrees +/- 3.8 degrees), TA (42.5 degrees +/- 4.0 degrees), HD (4.9 +/- 1.1) mm, and VD (19.1 +/- 2.3) mm, no significant differences were identified (P > 0.05). CONCLUSIONS: S2AI screw placement assisted by a 3D-printed surgical guide is safe and accurate.
引用
收藏
页码:E161 / E167
页数:7
相关论文
共 50 条
  • [31] Risk Factors for Loosening of S2 Alar Iliac Screw: Surgical Outcomes of Adult Spinal Deformity
    Iijima, Yasushi
    Kotani, Toshiaki
    Sakuma, Tsuyoshi
    Nakayama, Keita
    Akazawa, Tsutomu
    Kishida, Shunji
    Muramatsu, Yuta
    Sasaki, Yu
    Ueno, Keisuke
    Asada, Tomoyuki
    Sato, Kosuke
    Minami, Shohei
    Ohtori, Seiji
    ASIAN SPINE JOURNAL, 2020, 14 (06) : 864 - 871
  • [32] Evaluation of iliac screw, S2 alar-iliac screw and laterally placed triangular titanium implants for sacropelvic fixation in combination with posterior lumbar instrumentation: a finite element study
    Gloria Casaroli
    Fabio Galbusera
    Ruchi Chande
    Derek Lindsey
    Ali Mesiwala
    Scott Yerby
    Marco Brayda-Bruno
    European Spine Journal, 2019, 28 : 1724 - 1732
  • [33] The Influence of Radiographic Parameter on the S2 Alar-Iliac Screw Virtual Trajectory in Degenerative Lumbar Scoliosis Patients: A Computed Tomography Study
    Jiang, Jun
    Song, Chenyu
    Wang, Han
    Qiu, Yong
    Wang, Bin
    Zhu, Zezhang
    Yu, Yang
    ORTHOPAEDIC SURGERY, 2024, 16 (06) : 1356 - 1363
  • [34] The accuracy of a partially guided system using an in-office 3D-printed surgical guide for implant placement
    Cho, Jin-yong
    Kim, Sung-beom
    Ryu, Jaeyoung
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2021, 24 (01) : 19 - 27
  • [35] Anatomic trajectory for iliac screw placement adapts better to the morphological features of the pelvis of each individual than the S2 alar iliac screw: a radiological study
    Galovich, Luis Alvarez
    Bordon, Julia Montoya
    Blanco, Irantzu Castelbon
    Peiro, Alejandro
    Mengis, Charles Louis
    Pinera, Angel R.
    Tome-Bermejo, Felix
    Gallego, Jesus
    ACTA NEUROCHIRURGICA, 2023, 165 (09) : 2607 - 2614
  • [36] Anatomic trajectory for iliac screw placement adapts better to the morphological features of the pelvis of each individual than the S2 alar iliac screw: a radiological study
    Luis Álvarez Galovich
    Julia Montoya Bordón
    Irantzu Castelbon Blanco
    Alejandro Peiro
    Charles Louis Mengis
    Ángel R. Piñera
    Félix Tomé-Bermejo
    Jesus Gallego
    Acta Neurochirurgica, 2023, 165 : 2607 - 2614
  • [37] 3D-printed drill guide template, a promising tool to improve pedicle screw placement accuracy in spinal deformity surgery: A systematic review and meta-analysis
    Weishi Liang
    Bo Han
    Junrui Jonathan Hai
    Yong Hai
    Long Chen
    Nan Kang
    Peng Yin
    European Spine Journal, 2021, 30 : 1173 - 1183
  • [38] Pedicle screw placement in spinal neurosurgery using a 3D-printed drill guide template: a systematic review and meta-analysis
    Chengqiang Yu
    Yufu Ou
    Chengxin Xie
    Yu Zhang
    Jianxun Wei
    Xiaoping Mu
    Journal of Orthopaedic Surgery and Research, 15
  • [39] 3D-printed drill guide template, a promising tool to improve pedicle screw placement accuracy in spinal deformity surgery: A systematic review and meta-analysis
    Liang, Weishi
    Han, Bo
    Hai, Junrui Jonathan
    Hai, Yong
    Chen, Long
    Kang, Nan
    Yin, Peng
    EUROPEAN SPINE JOURNAL, 2021, 30 (05) : 1173 - 1183
  • [40] Pedicle screw placement in spinal neurosurgery using a 3D-printed drill guide template: a systematic review and meta-analysis
    Yu, Chengqiang
    Ou, Yufu
    Xie, Chengxin
    Zhang, Yu
    Wei, Jianxun
    Mu, Xiaoping
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)