Accuracy of S2 Alar-Iliac Screw Placement Under the Guidance of a 3D-Printed Surgical Guide Template

被引:5
|
作者
Zhao, Yonghui [1 ,2 ]
Luo, Haotian [1 ]
Ma, Yulong [2 ]
Liang, Jinlong [2 ]
Han, Gonghai [1 ]
Xu, Yongqing [2 ]
Lu, Sheng [1 ]
机构
[1] Kunming Univ Sci & Technol, Peoples Hosp Yunnan Prov 1, Dept Orthoped, Key Lab Digital Orthoped Yunnan Prov,Affiliated H, Kunming, Yunnan, Peoples R China
[2] 920 Hosp Joint Logist Support Force, Dept Orthoped, Kunming, Yunnan, Peoples R China
基金
中国国家自然科学基金;
关键词
3D printing technology; Accuracy; S2AI screw; Surgical guide template; MINIMUM 5-YEAR ANALYSIS; SACROPELVIC FIXATION; PELVIC FIXATION; LONG FUSIONS; SPINE; ADULT; SACRUM; COMPLICATIONS; S1;
D O I
10.1016/j.wneu.2020.10.063
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: To evaluate the safety and accuracy of S2 alar-iliac (S2AI) screw placement guided by a 3-dimensional (3D)-printed surgical guide template. - METHODS: The data of 27 patients treated with S2AI screws were analyzed. S2AI surgical guide templates were designed and printed, and S2AI screw placement was completed intraoperatively with the guide templates. Postoperative computed tomography was performed to measure screw path parameters, namely the sagittal angle (SA), the transverse angle (TA), the horizontal distance (HD) between the entry point of the screw and the median sacral crest, and the vertical distance (VD) between the entry point of the screw and the lower edge of the first posterior sacral foramen. Screw placement was graded according to the Oh grading criteria. RESULTS: A total of 54 S2AI screws were placed. The screw grades were as follows: 52 screws were considered grade 0, 2 were grade 1, none were grade 2, and none were grade 3. Thus grade 0 accounted for 96.3% of the screws. When the preoperatively planned SA (32.3 degrees +/- 2.0 degrees), TA (42.1 degrees +/- 3.9 degrees), HD (5.1 +/- 1.1) mm, and VD (19.0 +/- 2.4) mm were compared with the corresponding postoperative SA ( 31.9 degrees +/- 3.8 degrees), TA (42.5 degrees +/- 4.0 degrees), HD (4.9 +/- 1.1) mm, and VD (19.1 +/- 2.3) mm, no significant differences were identified (P > 0.05). CONCLUSIONS: S2AI screw placement assisted by a 3D-printed surgical guide is safe and accurate.
引用
收藏
页码:E161 / E167
页数:7
相关论文
共 50 条
  • [21] Clinical Outcomes Associated with Screw Loosening in S2 Alar-Iliac Fixation in Adult Spinal Deformity
    Nagatani, Yasuhiro
    Nakashima, Hiroaki
    Kanemura, Tokumi
    Tsushima, Mikito
    Tomita, Hiroyuki
    Morishita, Kazuaki
    Oyama, Hiroki
    Ito, Sadayuki
    Segi, Naoki
    Ouchida, Jun
    Yamauchi, Ippei
    Ode, Yukihito
    Okada, Yuya
    Imagama, Shiro
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (06)
  • [22] Human versus Robot A Propensity-Matched Analysis of the Accuracy of Free Hand versus Robotic Guidance for Placement of S2 Alar-Iliac (S2AI) Screws
    Shillingford, Jamal N.
    Laratta, Joseph L.
    Park, Paul J.
    Lombardi, Joseph M.
    Tuchman, Alexander
    Saifi, Comron
    Lehman, Ronald A., Jr.
    Lenke, Lawrence G.
    SPINE, 2018, 43 (21) : E1297 - E1304
  • [23] Radiological Evaluation of Pelvic Morphology for S2 Alar-Iliac Screw Insertion in the Japanese Samples: A Retrospective Cohort Study
    Masuda, Keisuke
    Shigematsu, Hideki
    Inoue, Daisuke
    Iwata, Eiichiro
    Tanaka, Masato
    Okuda, Akinori
    Kawasaki, Sachiko
    Suga, Yuma
    Yamamoto, Yusuke
    Tanaka, Yasuhito
    SPINE SURGERY AND RELATED RESEARCH, 2022, 6 (06): : 704 - 710
  • [24] The Accurate Free-hand Placement of S2 Alar Iliac (S2AI) Screw
    Fang, Taolin
    Russo, Glenn S.
    Schroeder, Gregory D.
    Kepler, Christopher K.
    CLINICAL SPINE SURGERY, 2020, 33 (03): : 102 - 103
  • [25] The Prevalence and Risk Factors for S2 Alar-Iliac Screw Loosening with a Minimum 2-Year Follow-up
    Nakashima, Hiroaki
    Kanemura, Tokumi
    Satake, Kotaro
    Ito, Kenyu
    Ishikawa, Yoshimoto
    Ouchida, Jun
    Segi, Naoki
    Yamaguchi, Hidetoshi
    Imagama, Shiro
    ASIAN SPINE JOURNAL, 2020, 14 (02) : 177 - 184
  • [26] Accuracy of a simplified 3D-printed implant surgical guide
    Kim, Taehun
    Lee, Sangwook
    Kim, Guk Bae
    Hong, Dayeong
    Kwon, Jinhee
    Park, Jae-Woo
    Kim, Namkug
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (02): : 195 - +
  • [27] Biomechanical investigation of S2 alar-iliac screw and S1 pedicle screw fixation in the treatment of Denis type II sacral fractures
    Zheng, Jianxiong
    Liu, Fei
    Xiang, Jie
    Leung, Frankie K. L.
    Feng, Xiaoreng
    Chen, Bin
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2023, 41 (01) : 215 - 224
  • [28] Robotic-guided sacro-pelvic fixation using S2 alar-iliac screws: feasibility and accuracy
    Xiaobang Hu
    Isador H. Lieberman
    European Spine Journal, 2017, 26 : 720 - 725
  • [29] Robotic-guided sacro-pelvic fixation using S2 alar-iliac screws: feasibility and accuracy
    Hu, Xiaobang
    Lieberman, Isador H.
    EUROPEAN SPINE JOURNAL, 2017, 26 (03) : 720 - 725
  • [30] Evaluation of iliac screw, S2 alar-iliac screw and laterally placed triangular titanium implants for sacropelvic fixation in combination with posterior lumbar instrumentation: a finite element study
    Casaroli, Gloria
    Galbusera, Fabio
    Chande, Ruchi
    Lindsey, Derek
    Mesiwala, Ali
    Yerby, Scott
    Brayda-Bruno, Marco
    EUROPEAN SPINE JOURNAL, 2019, 28 (07) : 1724 - 1732