Total Hip Arthroplasty Using Hybrid Ceramic Bearing: A Minimum 10-Year Followup Study

被引:5
|
作者
Yoo, Jun-Il [1 ]
Ha, Yong-Chan [2 ]
Kim, Dong-Hyun [2 ]
Lee, Young-Kyun [3 ]
Koo, Kyung-Hoi [3 ]
机构
[1] Gyeongsang Natl Univ Hosp, Dept Orthopaed Surg, Jinju, South Korea
[2] Chung Ang Univ, Dept Orthopaed Surg, Coll Med, 102 Heukseok Ro, Seoul 156755, South Korea
[3] Seoul Natl Univ, Dept Orthopaed Surg, Bundang Hosp, Bundang, South Korea
关键词
Cementless; delta liner; large diameter femoral head; survival; total hip arthroplasty; HEAD; ARTICULATION; FRACTURES; FIXATION;
D O I
10.4103/ortho.IJOrtho_416_18
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Contemporary ceramic articulation in total hip arthroplasty (THA) has shown successful clinical and radiologic outcomes at mid-to-long term. Delta ceramic, which includes 24% zirconia, has been developed to reduce the rate of ceramic fracture. However, the phase transformation of the zirconia that might cause surface roughness, ceramic wear, and subsequent osteolysis remains a concern. The purpose of this study was to evaluate clinicoradiological outcomes, ceramic-related complications, and survivorship of THA with the use of hybrid ceramic bearing; BIOLOX delta liner-on-BIOLOX forte head articulation at a minimum followup of 10 years. Materials and Methods: One hundred cementless THAs (85 patients) were performed with the use of 36-mm hybrid ceramic bearing. The thickness of the delta ceramic liner was 4-6 mm. Four patients (4 hips) were lost and six patients (6 hips) died within 10 years after the operation. Thus, the remaining 75 patients (90 hips) were followed up for 10-12 years. There were 43 men and 32 women. The mean age of these patients at the index operation was 58 years (21-78 years). Results: There were no fractures of ceramic liner or head. There was no measurable ceramic wear, and neither pelvic nor femoral osteolysis was identified. All acetabular and femoral components were bone-ingrown. Three (3/90, 3.3%) patients noted noise of clicking sound. The mean Harris hip score was 87 points (range 72-99 points) at the time of final followup. THA survivorship with revision surgery as an endpoint was 97.8% (95% confidence interval: 91.4%-99.8%). Conclusions: The long term result of cementless THA with the use of a large BIOLOX forte head on the BIOLOX delta liner showed an encouraging result. Wear or osteolysis associated with composite of 24% zirconia in the fourth-generation ceramic was not observed at a minimum followup of 10 years.
引用
收藏
页码:637 / 640
页数:4
相关论文
共 50 条
  • [41] Minimum 10-Year Follow-Up of Cementless Total Hip Arthroplasty Using a Contemporary Triple-Tapered Titanium Stem
    Carlson, Samuel W.
    Goetz, Devon D.
    Liu, Steve S.
    Greiner, Justin J.
    Callaghan, John J.
    [J]. JOURNAL OF ARTHROPLASTY, 2016, 31 (10): : 2231 - 2236
  • [42] Acetabular Revision Total Hip Arthroplasty Using an Impacted Morselized Allograft and a Cementless Cup Minimum 10-Year Follow-Up
    Lee, Joong-Myung
    Nam, Hee-Tae
    [J]. JOURNAL OF ARTHROPLASTY, 2011, 26 (07): : 1057 - 1060
  • [43] Ceramic Materials as Bearing Surfaces for Total Hip Arthroplasty
    D'Antonio, James A.
    Sutton, Kate
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2009, 17 (02) : 63 - 68
  • [44] Cost analysis of revision total hip arthroplasty -: A 5-year followup study
    Barrack, RL
    Sawhney, J
    Hsu, J
    Cofield, RH
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (369) : 175 - 178
  • [45] Malpractice litigation after total hip arthroplasty: A legal 10-year database
    Sonmez, Mehmet Mesut
    Alpsoy, Mehmet Yilmaz
    Ozdemir, Emre
    Sevin, Abdulvahap
    Kaygusuz, Mehmet Akif
    [J]. JOINT DISEASES AND RELATED SURGERY, 2023, 34 (02): : 389 - 395
  • [46] Uncemented total hip arthroplasty in osteonecrosis - A 2- to 10-year evaluation
    Stulberg, BN
    Singer, R
    Goldner, J
    Stulberg, J
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1997, (334) : 116 - 123
  • [47] 10-YEAR FOLLOW-UP OF THE CHARNLEY TOTAL HIP-ARTHROPLASTY
    CEDELL, CA
    SVENDLER, CA
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (03): : 308 - 308
  • [48] CHARNLEY TOTAL HIP-ARTHROPLASTY - A 10-YEAR TO 14-YEAR FOLLOW-UP-STUDY
    WEJKNER, B
    STENPORT, J
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1988, (231) : 113 - 119
  • [49] NexGen® LPS mobile bearing total knee arthroplasty: 10-year results
    Alessandro Bistolfi
    Gwo-Chin Lee
    Davide Deledda
    Federica Rosso
    Paola Berchialla
    Maurizio Crova
    Giuseppe Massazza
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 1786 - 1792
  • [50] NexGenA® LPS mobile bearing total knee arthroplasty: 10-year results
    Bistolfi, Alessandro
    Lee, Gwo-Chin
    Deledda, Davide
    Rosso, Federica
    Berchialla, Paola
    Crova, Maurizio
    Massazza, Giuseppe
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (08) : 1786 - 1792