Acetabular Revision Total Hip Arthroplasty Using an Impacted Morselized Allograft and a Cementless Cup Minimum 10-Year Follow-Up

被引:21
|
作者
Lee, Joong-Myung [1 ]
Nam, Hee-Tae [1 ]
机构
[1] Natl Med Ctr, Dept Orthoped Surg, Seoul 100799, South Korea
来源
JOURNAL OF ARTHROPLASTY | 2011年 / 26卷 / 07期
关键词
acetabular revision arthroplasty; impacted morselized allograft; cementless cup; BONE STOCK; CLASSIFICATION; REPLACEMENT; RECONSTRUCTION; MANAGEMENT;
D O I
10.1016/j.arth.2011.03.035
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study was undertaken to analyze the clinical and radiologic results of acetabular revision arthroplasty using an impacted morselized allograft and a cementless cup and was performed on 71 hips of 62 patients who were followed up for a minimum of 10 years (10 years to 14 years 8 months; mean, 12 years). The acetabular bone defects were classified using the American Academy of Orthopaedic Surgeons Committee on the Hip and Paprosky classifications. Cement less hemispherical cups were inserted via a press-fit technique, using an impacted morselized allograft. The mean Harris hip score at the last follow-up visit was 92. Only 3 cases were re-revised, and the 12-year survival rate was thus 95.8%. The study shows that acetabular revision arthroplasty using an impacted morselized allograft and a cementless cup is an excellent treatment option.
引用
收藏
页码:1057 / 1060
页数:4
相关论文
共 50 条
  • [1] Acetabular revision for aseptic loosening in total hip arthroplasty using cementless cup and impacted morselized allograft
    Parratte, S.
    Argenson, J.-N.
    Flecher, X.
    Aubaniac, J.-M.
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2007, 93 (03): : 255 - 263
  • [2] Modular acetabular reconstructive cup in acetabular revision total hip arthroplasty at a minimum ten year follow-up
    Sakai, Takashi
    Ohzono, Kenji
    Nishii, Takashi
    Takao, Masaki
    Miki, Hidenobu
    Nakamura, Nobuo
    Sugano, Nobuhiko
    INTERNATIONAL ORTHOPAEDICS, 2013, 37 (04) : 605 - 610
  • [3] Modular acetabular reconstructive cup in acetabular revision total hip arthroplasty at a minimum ten year follow-up
    Takashi Sakai
    Kenji Ohzono
    Takashi Nishii
    Masaki Takao
    Hidenobu Miki
    Nobuo Nakamura
    Nobuhiko Sugano
    International Orthopaedics, 2013, 37 : 605 - 610
  • [4] Structural and Morselized Allografting Combined with a Cementless Cup for Acetabular Defects in Revision Total Hip Arthroplasty: A 4-to 14-Year Follow-Up
    Chen, Hou-Tsung
    Wu, Cheng-Ta
    Huang, Tsan-Wen
    Shih, Hsin-Nung
    Wang, Jun-Wen
    Lee, Mel S.
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [5] Cortical and cancellous morselized allograft in acetabular revision total hip replacement - Minimum 5-year follow-up
    Kligman, M
    Padgett, DE
    Vered, R
    Roffman, M
    JOURNAL OF ARTHROPLASTY, 2003, 18 (07): : 907 - 913
  • [6] Total hip arthroplasty using hydroxyapatite-coated cementless cup for rapidly destructive coxarthrosis: Minimum 10-year follow-up
    Sonohata, Motoki
    Nakashima, Takema
    Kitajima, Masaru
    Kawano, Shunsuke
    Eto, Shuichi
    Mawatari, Masaaki
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2021, 26 (02) : 225 - 229
  • [7] Acetabular reinforcement ring in primary total hip arthroplasty: a minimum 10-year follow-up
    Sadri, Hassan
    Pfander, Gregoire
    Siebenrock, Klaus-Arno
    Tannast, Moritz
    Koch, Peter
    Fujita, Hiroshi
    Ballmer, Peter
    Ganz, Reinhold
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (08) : 869 - 877
  • [8] Acetabular reinforcement ring in primary total hip arthroplasty: a minimum 10-year follow-up
    Hassan Sadri
    Grégoire Pfander
    Klaus-Arno Siebenrock
    Moritz Tannast
    Peter Koch
    Hiroshi Fujita
    Peter Ballmer
    Reinhold Ganz
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 869 - 877
  • [9] Cementless Lord total hip arthroplasty - Cup loosening common after minimum 10-year follow-up of 103 hips
    Kubo, T
    Inoue, S
    Maeda, T
    Arai, Y
    Hirakawa, K
    Wu, YP
    Suehara, H
    Ogura, T
    Hirasawa, Y
    ACTA ORTHOPAEDICA SCANDINAVICA, 2001, 72 (06): : 585 - 590
  • [10] Revision Total Hip Arthroplasty Using a Cementless Cup Supporter and Iliac Autograft: A Minimum of 15-Year Follow-Up
    Yoshino, Kensuke
    Tsukeoka, Tadashi
    Tsuneizumi, Yoshikazu
    Lee, Tae Hyun
    Nakamura, Junichi
    Suzuki, Masahiko
    Ohtori, Seiji
    JOURNAL OF ARTHROPLASTY, 2017, 32 (11): : 3495 - 3501