Acetabular reinforcement ring in primary total hip arthroplasty: a minimum 10-year follow-up

被引:8
|
作者
Sadri, Hassan [1 ]
Pfander, Gregoire [1 ]
Siebenrock, Klaus-Arno [1 ]
Tannast, Moritz [1 ]
Koch, Peter [1 ]
Fujita, Hiroshi [1 ]
Ballmer, Peter [2 ]
Ganz, Reinhold [1 ]
机构
[1] Univ Bern, Inselspital, Dept Orthopaed Surg, CH-3010 Bern, Switzerland
[2] Clin Orthopaed Surg, Spital Thun, Thun, Switzerland
关键词
total hip arthroplasty; long-term results; acetabular reinforcement ring with hook; cemented;
D O I
10.1007/s00402-008-0612-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction We report the results of a titanium acetabular reinforcement ring with a hook (ARRH) in primary total hip arthroplasty (THA), which was introduced in 1987 and continues to be used routinely in our center. The favorable results of this device in arthroplasty for developmental dysplasia and difficult revisions motivated its use in primary THA. With this implant only minimal acetabular reaming is necessary, anatomic positioning is achieved by placing the hook around the teardrop and a homogenous base for cementing the polyethylene cup is provided. Materials and methods Between April 1987 and December 1991, 241 THAs with insertion of an ARRH were performed in 178 unselected, consecutive patients (average age 58 years; range 30-84 years) with a secondary osteoarthrosis in 41% of the cases. Results At the time of the latest follow-up, 33 patients (39 hips) had died and 17 cases had been lost to follow-up. The median follow-up was 122 months with a minimum of 10 years. Eight hips had been revised, leaving 177 hips in 120 living patients without revision. Six cups were revised because of aseptic loosening. Two hips were revised for sepsis. The mean Merle d'Aubigne score for the remaining hips was 16 (range 7-18) at the latest follow-up. For aseptic loosening, the probability of survival of the cup was 0.97 (95% confidence interval, 0.94-0.99). However, analysis of radiographs implied loosening in seven other cups without clinical symptoms. Conclusions The results of primary THA using an acetabular reinforcement ring parallel the excellent results of these implants often observed in difficult primary and revision arthroplasty at a minimum of 10 years. Survivorship is comparable to modern cementless implants. Medial migration that occurs with loosening of the acetabular component seems to be prevented with this implant. Radiographic loosening signs can exist without clinical symptoms.
引用
收藏
页码:869 / 877
页数:9
相关论文
共 50 条
  • [1] Acetabular reinforcement ring in primary total hip arthroplasty: a minimum 10-year follow-up
    Hassan Sadri
    Grégoire Pfander
    Klaus-Arno Siebenrock
    Moritz Tannast
    Peter Koch
    Hiroshi Fujita
    Peter Ballmer
    Reinhold Ganz
    [J]. Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 869 - 877
  • [2] Acetabular reinforcement ring with hook for complex acetabular revision in total hip arthroplasty. A minimum follow-up of 10 years
    Siebenrock, KA
    Trochsler, M
    Sadri, H
    Ganz, R
    [J]. ORTHOPADE, 2001, 30 (05): : 273 - +
  • [3] Acetabular reconstruction using a roof reinforcement ring with hook for total hip arthroplasty in developmental dysplasia of the hip-osteoarthritis - Minimum 10-year follow-up results
    Siebenrock, KA
    Tannast, M
    Kim, S
    Morgenstern, W
    Ganz, R
    [J]. JOURNAL OF ARTHROPLASTY, 2005, 20 (04): : 492 - 498
  • [4] Acetabular Revision Total Hip Arthroplasty Using an Impacted Morselized Allograft and a Cementless Cup Minimum 10-Year Follow-Up
    Lee, Joong-Myung
    Nam, Hee-Tae
    [J]. JOURNAL OF ARTHROPLASTY, 2011, 26 (07): : 1057 - 1060
  • [5] Revision Total Hip Arthroplasty Utilizing an Acetabular Reinforcement Ring with a Metal Augment: A Minimum Eight-Year Follow-Up Study
    Kim, Han Soul
    Kim, Ji Wan
    Chang, Jae Suk
    Kim, Chul-Ho
    [J]. MEDICINA-LITHUANIA, 2023, 59 (06):
  • [6] TOTAL HIP-ARTHROPLASTY IN THE ANKYLOSED HIP - A 10-YEAR FOLLOW-UP
    STRATHY, GM
    FITZGERALD, RH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (07): : 963 - 966
  • [7] 10-YEAR FOLLOW-UP OF THE CHARNLEY TOTAL HIP-ARTHROPLASTY
    CEDELL, CA
    SVENDLER, CA
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (03): : 308 - 308
  • [8] Total hip arthroplasty in patients younger than 21 years: a minimum 10-year follow-up
    Bessette, BIJ
    Fassier, F
    Tanzer, M
    Brooks, CE
    [J]. CANADIAN JOURNAL OF SURGERY, 2003, 46 (04) : 257 - 262
  • [9] Results of revision total hip arthroplasty with Anatomic BR stem: 10-year minimum follow-up
    Tsukeoka, Tadashi
    Lee, Tae Hyun
    Tsuruoka, Hiroaki
    Murata, Tadao
    Suzuki, Masahiko
    [J]. MODERN RHEUMATOLOGY, 2011, 21 (05) : 482 - 487
  • [10] Revision total hip arthroplasty with the use of structural acetabular allograft and reconstruction ring - A case series with a 10-year average follow-up
    Saleh, KJ
    Jaroszynski, G
    Woodgate, I
    Saleh, L
    Gross, AE
    [J]. JOURNAL OF ARTHROPLASTY, 2000, 15 (08): : 951 - 958