Revision Total Hip Arthroplasty Utilizing an Acetabular Reinforcement Ring with a Metal Augment: A Minimum Eight-Year Follow-Up Study

被引:0
|
作者
Kim, Han Soul [1 ]
Kim, Ji Wan [2 ]
Chang, Jae Suk [3 ]
Kim, Chul-Ho [2 ]
机构
[1] Gachon Univ Gil Med Ctr, Dept Orthoped Surg, Incheon 21565, South Korea
[2] Univ Ulsan, Asan Med Ctr, Dept Orthoped Surg, Coll Med, Seoul 05505, South Korea
[3] Natl Police Hosp, Dept Orthoped Surg, Seoul 05715, South Korea
来源
MEDICINA-LITHUANIA | 2023年 / 59卷 / 06期
关键词
acetabular reinforcement ring; metal augment; hip arthroplasty; revision; TRABECULAR METAL; BONE LOSS; RECONSTRUCTION; DEFECTS; COMPONENT; MANAGEMENT; CAGE; CLASSIFICATION; ALLOGRAFT;
D O I
10.3390/medicina59061036
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives: An acetabular reinforcement ring (ARR) with a structural allograft is conventionally used to treat large acetabular bone defects or discontinuity during revision hip arthroplasty. However, ARR is prone to failure due to bone resorption and lack of incorporation. Here, we investigated the surgical outcomes of the patients who underwent revision total hip arthroplasty (THA) using ARR combined with a metal augment (MA). Materials and Methods: We retrospectively reviewed data from 10 consecutive patients who had a minimum 8-year follow-up after revision hip arthroplasty using ARR with MA in Paprosky type III acetabular defect. We collected patient demographics, surgical details, clinical scores (including Harris Hip Score (HHS)), postoperative complications, and 8-year survival rates. Results: Six male and four female patients were included. The mean age was 64.3 years, and the mean follow-up duration was 104.3 months (96.0-112.0 months). Trauma-related diagnosis was the most common reason for index surgery. Three patients underwent all component revision, and seven underwent cup revision. Six were confirmed as Paprosky type IIIA and four as type IIIB. The mean HHS at the final follow-up was 81.5 (72-91). One patient was diagnosed with prosthetic joint infection at the 3-month follow-up; therefore, the minimum 8-year survival rate with our technique was 90.0% (95% confidence interval, 90.3-118.5%). Conclusions: The satisfactory mid- to long-term results of revision THA suggest that ARR combined with tantalum MA is a viable revision option for treating severe acetabular defects with pelvic discontinuity.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Acetabular reinforcement ring in primary total hip arthroplasty: a minimum 10-year follow-up
    Sadri, Hassan
    Pfander, Gregoire
    Siebenrock, Klaus-Arno
    Tannast, Moritz
    Koch, Peter
    Fujita, Hiroshi
    Ballmer, Peter
    Ganz, Reinhold
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (08) : 869 - 877
  • [2] Acetabular reinforcement ring in primary total hip arthroplasty: a minimum 10-year follow-up
    Hassan Sadri
    Grégoire Pfander
    Klaus-Arno Siebenrock
    Moritz Tannast
    Peter Koch
    Hiroshi Fujita
    Peter Ballmer
    Reinhold Ganz
    [J]. Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 869 - 877
  • [3] Acetabular reinforcement ring with hook for complex acetabular revision in total hip arthroplasty. A minimum follow-up of 10 years
    Siebenrock, KA
    Trochsler, M
    Sadri, H
    Ganz, R
    [J]. ORTHOPADE, 2001, 30 (05): : 273 - +
  • [4] Modular acetabular reconstructive cup in acetabular revision total hip arthroplasty at a minimum ten year follow-up
    Sakai, Takashi
    Ohzono, Kenji
    Nishii, Takashi
    Takao, Masaki
    Miki, Hidenobu
    Nakamura, Nobuo
    Sugano, Nobuhiko
    [J]. INTERNATIONAL ORTHOPAEDICS, 2013, 37 (04) : 605 - 610
  • [5] Modular acetabular reconstructive cup in acetabular revision total hip arthroplasty at a minimum ten year follow-up
    Takashi Sakai
    Kenji Ohzono
    Takashi Nishii
    Masaki Takao
    Hidenobu Miki
    Nobuo Nakamura
    Nobuhiko Sugano
    [J]. International Orthopaedics, 2013, 37 : 605 - 610
  • [6] Revision of the acetabular component of a total hip arthroplasty with a massive structural allograft - Study with a minimum five-year follow-up
    Garbuz, D
    Morsi, E
    Gross, AE
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (05): : 693 - 697
  • [7] Charnley-Kerboull total hip arthroplasty combining zirconia on polyethylene. A minimum eight-year follow-up prospective study
    Jean Langlois
    Samer El Hage
    Faouzi Madi
    Jean-Pierre Courpied
    Marcel Kerboull
    Moussa Hamadouche
    [J]. International Orthopaedics, 2013, 37 : 355 - 360
  • [8] Charnley-Kerboull total hip arthroplasty combining zirconia on polyethylene. A minimum eight-year follow-up prospective study
    Langlois, Jean
    El Hage, Samer
    Madi, Faouzi
    Courpied, Jean-Pierre
    Kerboull, Marcel
    Hamadouche, Moussa
    [J]. INTERNATIONAL ORTHOPAEDICS, 2013, 37 (03) : 355 - 360
  • [9] Revision Total Hip Arthroplasty Using an Acetabular Reinforcement Ring With a Hook: A Precise Follow-Up, at Average 11.4 Years, of a Previous Report
    Park, Kyung-Soon
    Seon, Jong-Keun
    Lee, Keun-Bae
    Kim, Sung-Kyu
    Chan, Chee-Ken
    Yoon, Taek-Rim
    [J]. JOURNAL OF ARTHROPLASTY, 2017, 32 (02): : 503 - 509
  • [10] Total hip arthroplasty revision by dual-mobility acetabular cup cemented in a metal reinforcement: A 62 case series at a minimum 5 years' follow-up
    Lebeau, N.
    Bayle, M.
    Belhaouane, R.
    Chelli, M.
    Havet, E.
    Brunschweiler, B.
    Mertl, P.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (05) : 679 - 684