Investigation of a whole-body DOI-PET system

被引:11
|
作者
Ohi, Junichi [1 ]
Tonami, Hiromichi [1 ]
机构
[1] Shimadzu Co Ltd, Kyoto 6048422, Japan
关键词
PET; DOI; nuclear medicine; gamma-ray detector;
D O I
10.1016/j.nima.2006.10.068
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this study, we were conducting basic research on a whole-body depth of gamma-ray interaction (DOI) positron emission tomography system which provides spatial resolution that is both high and uniform, and also minimizes costs. The detectors consist of double-layer 9 x 10 GSO/GSO phoswich crystal blocks, a light guide and two rectangular PMTs. Individual crystal sizes are 2.45 x 5.1 x 15 mm(3). and each layer of crystal blocks has a different decay time. Many of the circuit boards used in our current conventional PET system (SET-3000G SHIMADZU Japan) have been optimized for DOI acquisition. The detectors are arranged to form a 332.5 mm radius detection ring, and spatial resolution is obtained from the center to the edge of the 250 mm radius field of view. The effect of DOI was confirmed using a comparison with the non-DOI systems. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:223 / 226
页数:4
相关论文
共 50 条
  • [1] Development of a high resolution whole-body DOI PET system
    Ohtani, Atsushi
    Tanaka, Kazumi
    Kitamura, Keishi
    Mizuta, Tetsuro
    Inoue, Yoshihiro
    Tonami, Hiromichi
    Ohi, Junichi
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3695 - +
  • [2] Investigation of a compact DOI-PET system for small animal imaging
    Kao, CM
    Schmand, M
    Gives, G
    Pan, XC
    Nutt, R
    Chen, CT
    [J]. 2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1292 - 1297
  • [3] Optimization of Enhanced Energy Window on a Whole-Body DOI PET System
    Ohtani, Atsushi
    Tanaka, Kazumi
    Mizuta, Tetsuro
    Inoue, Yoshihiro
    Tonami, Hiromichi
    Ohi, Junichi
    Kitamura, Keishi
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3618 - +
  • [4] Development of a High-Spatial-Resolution Whole-Body DOI PET System Using LGSO/GSO Crystals
    Ohtani, Atsushi
    Tanaka, Kazumi
    Kitamura, Keishi
    Mizuta, Tetsuro
    Inoue, Yoshihiro
    Tonami, Hiromichi
    Ohi, Junichi
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3969 - +
  • [5] A Dual-Layer TOF-DOI Detector Block for Whole-Body PET
    Liu, Shitao
    An, Shaohui
    Li, Hongdi
    Wang, Chao
    Ramirez, Rocio A.
    Zhang, Yuxuan
    Baghaei, Hossain
    Wong, Wai-Hoi
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) : 1805 - 1808
  • [6] A Modified Spatial Resolution Formula for DOI-PET
    Xia, Yan
    Ma, Tianyu
    Liu, Yaqiang
    Wang, Shi
    Shao, Yiping
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2632 - 2635
  • [7] DOI-PET image reconstruction with accurate system model reducing redundancy of imaging system
    Yamaya, T
    Hagiwara, N
    Obi, T
    Yamaguchi, M
    Kita, K
    Ohyama, N
    Kitamura, K
    Hasegawa, T
    Haneishi, H
    Murayama, H
    [J]. 2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1226 - 1230
  • [8] Diagnostic accuracy of whole-body PET/MRI and whole-body PET/CT for TNM staging in oncology
    Philipp Heusch
    Felix Nensa
    Benedikt Schaarschmidt
    Rupika Sivanesapillai
    Karsten Beiderwellen
    Benedikt Gomez
    Jens Köhler
    Henning Reis
    Verena Ruhlmann
    Christian Buchbender
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2015, 42 : 42 - 48
  • [9] Diagnostic accuracy of whole-body PET/MRI and whole-body PET/CT for TNM staging in oncology
    Heusch, Philipp
    Nensa, Felix
    Schaarschmidt, Benedikt
    Sivanesapillai, Rupika
    Beiderwellen, Karsten
    Gomez, Benedikt
    Koehler, Jens
    Reis, Henning
    Ruhlmann, Verena
    Buchbender, Christian
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (01) : 42 - 48
  • [10] Performance evaluation of a whole-body prototype PET scanner with four-layer DOI detectors
    Akamatsu, Go
    Tashima, Hideaki
    Iwao, Yuma
    Wakizaka, Hidekatsu
    Maeda, Takamasa
    Mohammadi, Akram
    Takyu, Sodai
    Nitta, Munetaka
    Nishikido, Fumihiko
    Rutherford, Harley
    Chacon, Andrew
    Safavi-Naeini, Mitra
    Yoshida, Eiji
    Yamaya, Taiga
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (09):