Early Diagnosis and Severity Assessment of Acute Pancreatitis (AP) Using MR Elastography (MRE) With Spin-Echo Echo-Planar Imaging

被引:16
|
作者
Shi, Yu [1 ]
Liu, Ying [1 ]
Liu, Yan-qing [1 ]
Gao, Feng [2 ]
Li, Jia-hui [1 ]
Li, Qiu-ju [1 ]
Guo, Qi-yong [1 ]
机构
[1] China Med Univ, Shengjing Hosp, Dept Radiol, 36 Sanhao St, Shenyang 110004, Liaoning, Peoples R China
[2] China Med Univ, Dept Hepatopancreatobiliary Tumour Surg, Shengjing Hosp, Shenyang, Liaoning, Peoples R China
基金
中国国家自然科学基金;
关键词
FATTY LIVER-DISEASE; MAGNETIC-RESONANCE-SPECTROSCOPY; NONALCOHOLIC STEATOHEPATITIS; HEPATIC STEATOSIS; INSULIN-RESISTANCE; ANIMAL-MODELS; MICE; QUANTIFICATION; CIRRHOSIS; BIOPSY;
D O I
10.1002/jmri.25679
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the accuracy of magnetic resonance elastography (MRE) in comparison to contrast-enhanced computed tomography (CE-CT) for early diagnosis and prediction of severity in acute pancreatitis (AP). Materials and Methods: This cross-sectional prospective study included 76 patients with suspected AP who underwent both CE-CT and 3.0T MRE within 24 hours of hospital admission. Pancreatic stiffness, CT severity index (CTSI), Acute Physiology and Chronic Health Evaluation (APACHE)-II, and Bedside Index for Severity in AP (BISAP) scores were comparatively evaluated using data from the first 24 hours of admission, and diagnosis and severity of AP were confirmed according to the revised Atlanta Classification (2012). The accuracy of MRE for predicting disease severity was compared with that of CE-CT and the clinical scoring systems using area under the receiver-operating curve (AUC) analysis. Results: AP was confirmed in 56/76 patients (73.7%). Pancreatic stiffness values of >1.47 kPa showed significantly better diagnostic performance than CE-CT (AUC: 0.993 vs. 0.818, P < 0.001) along with greater sensitivity (96.4% vs. 78.6%, P=0.006) and accuracy (96.1% vs. 81.6%, P=0.007). Ten patients (10/76; 13.2%) had clinically severe AP. The accuracy of pancreatic stiffness > 2.47 kPa was comparable to that of the CTSI, APACHE-II and BISAP scores for predicting severe AP (accuracy=85.5%, 75.0%, 88.2%, and 78.9%, respectively). The pairwise comparisons were not significant after Bonferroni correction (P < 0.008 [0.05/6]), with P values of 0.008 (MRE vs. CTSI), 0.823 (MRE vs. APACHE-II) and 0.414 (MRE vs. BISAP). Conclusion: Early MRE is a useful, noninvasive method for both diagnosis and early severity assessment of AP. We recommend MRE at hospital admission for initial evaluation of AP.
引用
收藏
页码:1311 / 1319
页数:9
相关论文
共 50 条
  • [31] Diffusion-weighted imaging of the brain: comparison of stimulated- and spin-echo echo-planar sequences
    S. Heiland
    O. Dietrich
    K. Sartor
    Neuroradiology, 2001, 43 : 442 - 447
  • [32] Multi-shot echo-planar Flair imaging of brain tumors: comparison of spin-echo T1-weighted, fast spin-echo T2-weighted, and fast spin-echo Flair imaging
    Tomura, N
    Kato, K
    Takahashi, S
    Sashi, R
    Izumi, J
    Narita, K
    Watarai, J
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (02) : 65 - 72
  • [33] Comparison of DWI Methods in the Pediatric Brain: PROPELLER Turbo Spin-Echo Imaging Versus Readout-Segmented Echo-Planar Imaging Versus Single-Shot Echo-Planar Imaging
    Kim, Tae-Hyung
    Baek, Moon-Young
    Park, Ji Eun
    Ryu, Young Jin
    Cheon, Jung-Eun
    Kim, In-One
    Choi, Young Hun
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (06) : 1352 - 1358
  • [34] Assessment of fetal lung growth in utero with echo-planar MR imaging
    Duncan, KR
    Gowland, PA
    Moore, RJ
    Baker, PN
    Johnson, IR
    RADIOLOGY, 1999, 210 (01) : 197 - 200
  • [35] PARTIAL RF ECHO-PLANAR IMAGING WITH THE FAISE METHOD .2. CONTRAST EQUIVALENCE WITH SPIN-ECHO SEQUENCES
    MELKI, PS
    JOLESZ, FA
    MULKERN, RV
    MAGNETIC RESONANCE IN MEDICINE, 1992, 26 (02) : 342 - 354
  • [36] ACUTE HYPERTENSIVE ENCEPHALOPATHY - FINDINGS ON SPIN-ECHO AND GRADIENT-ECHO MR-IMAGING
    WEINGARTEN, K
    BARBUT, D
    FILIPPI, C
    ZIMMERMAN, RD
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (03) : 665 - 670
  • [37] Determination of flow using half Fourier echo-planar MR imaging
    Rodríguez-González, AO
    REVISTA MEXICANA DE FISICA, 2000, 46 (02) : 177 - 189
  • [38] MR elastography in patients with suspected diffuse liver disease at 1.5T: Intraindividual comparison of gradient-recalled echo versus spin-echo echo-planar imaging sequences and investigation of potential confounding factors
    Plaikner, Michaela
    Kremser, Christian
    Zoller, Heinz
    Kannengiesser, Stephan
    Henninger, Benjamin
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 142
  • [39] Increased-contrast, high-spatial-resolution, diffusion-weighted, spin-echo, echo-planar imaging
    Thompson, MR
    Venkatesan, R
    Kuppusamy, K
    Celik, A
    Lin, WL
    Kido, DK
    Haacke, EM
    RADIOLOGY, 1999, 210 (01) : 253 - 259
  • [40] Optimization of gray/white matter contrast with fast inversion recovery for myelin suppression: A comparison of fast spin-echo and echo-planar MR imaging sequences
    Wolansky, LJ
    Finden, SG
    Chen, J
    Hanna, R
    Holodny, AI
    Ahmad, I
    Liu, WC
    Contractor, S
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1999, 20 (09) : 1653 - 1657