Dynamic stabilization of the lumbar spine and its effects on adjacent segments - An in vitro experiment

被引:252
|
作者
Schmoelz, W
Huber, JF
Nydegger, T
Claes, L
Wilke, HJ
机构
[1] Univ Ulm, Inst Orthopaed Res & Biomech, D-89081 Ulm, Germany
[2] Kantonsspital, Orthopaed Clin, Agrau, Switzerland
[3] Centerpulse Orthoped Ltd, Dept Biomech, Winterthur, Switzerland
来源
JOURNAL OF SPINAL DISORDERS & TECHNIQUES | 2003年 / 16卷 / 04期
关键词
lumbar spine; surgical treatment; biomechanics; mobility of adjacent segments;
D O I
10.1097/00024720-200308000-00015
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
In recent years, nonfusion stabilization of the lumbar spine has gained more and more popularity. These nonfusion systems intend to maintain or restore the intersegmental motions to magnitudes of the intact spine and have no negative effects on the segments adjacent to the stabilized one. This study investigated the DYNESYS, a dynamic nonfusion system, which is designed to stabilize the bridged segments while maintaining the disc and the facet joints. To determine the magnitude of stabilization and the effect of the stabilization on the adjacent segment, six lumbar cadaver spines were fixed in a spine tester and loaded with pure moments in the three main motion planes. For each spine, four different stages were tested: intact, defect of the middle segment, fixation with the DYNESYS, and fixation with the internal fixator. Intersegmental motions were measured at all levels. For the bridged segment, the DYNESYS stabilized the spine and was more flexible than the internal fixator. This difference between the internal fixator and the DYNESYS was most pronounced in extension (P < 0.05), with the DYNESYS restoring the motion back to the level of the intact spine. The motion in the adjacent segments was not influenced by either stabilization method. Our results suggest that the DYNESYS provides substantial stability in case of degenerative spinal pathologies and can therefore be considered as an alternative method to fusion surgery in these indications while the motion segment is preserved.
引用
收藏
页码:418 / 423
页数:6
相关论文
共 50 条
  • [21] Loading effects of anterior cervical spine fusion on adjacent segments
    Wang, Chien-Shiung
    Chang, Jia-Hao
    Chang, Ti-Sheng
    Chen, Hung-Yi
    Cheng, Ching-Wei
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2012, 28 (11): : 586 - 594
  • [22] Late infections after dynamic stabilization of the lumbar spine with Dynesys
    Jon A. Lutz
    Philippe Otten
    Gianluca Maestretti
    European Spine Journal, 2012, 21 : 2573 - 2579
  • [23] Dysfunctional Segmental Motion Treated with Dynamic Stabilization in the Lumbar Spine
    Cansever, Tufan
    Civelek, Erdinc
    Kabatas, Serdar
    Yilmaz, Cem
    Caner, Hakan
    Altinors, M. Nur
    WORLD NEUROSURGERY, 2011, 75 (5-6) : 743 - 749
  • [24] Late infections after dynamic stabilization of the lumbar spine with Dynesys
    Lutz, Jon A.
    Otten, Philippe
    Maestretti, Gianluca
    EUROPEAN SPINE JOURNAL, 2012, 21 (12) : 2573 - 2579
  • [25] Stability of posterior spinal instrumentation and its effects on adjacent motion segments in the lumbosacral spine - Point of view
    Lee, CK
    SPINE, 1998, 23 (14) : 1558 - 1558
  • [26] Applications of the Crenel Lateral Interbody Fusion Procedure in Treatment for Adjacent Segments Degeneration of the Lumbar Spine
    Zhang, Di
    Zeng, Tong
    Chen, Keng
    Jin, Song
    ORTHOPAEDIC SURGERY, 2022, 14 (09) : 2150 - 2158
  • [27] Effects of Lumbar Arthrodesis on Adjacent Segments Differences Between Surgical Techniques
    Kim, Tae Yup
    Kang, Kyoung Tak
    Yoon, Do Heum
    Shin, Hyun Chul
    Kim, Keung Nyun
    Yi, Seong
    Chun, Heoung Jae
    Oh, Jae Keun
    Choi, Gwi Hyun
    Lee, Kwang Il
    Ha, Yoon
    SPINE, 2012, 37 (17) : 1456 - 1462
  • [28] Kinematic evaluation of the adjacent segments after lumbar instrumented surgery: a comparison between rigid fusion and dynamic non-fusion stabilization
    Morishita, Yuichiro
    Ohta, Hideki
    Naito, Masatoshi
    Matsumoto, Yoshiyuki
    Huang, George
    Tatsumi, Masato
    Takemitsu, Yoshiharu
    Kida, Hirotaka
    EUROPEAN SPINE JOURNAL, 2011, 20 (09) : 1480 - 1485
  • [29] Dynamic Stabilization for Challenging Lumbar Degenerative Diseases of the Spine: A Review of the Literature
    Kaner, Tuncay
    Ozer, Ali Fahir
    ADVANCES IN ORTHOPEDICS, 2013, 2013
  • [30] Implant failure following pedicle based dynamic stabilization of the lumbar spine
    Schauvliege, Hans
    Du Bois, Marc
    Verlooy, Jan
    ACTA ORTHOPAEDICA BELGICA, 2021, 87 (01): : 191 - 196