Implant failure following pedicle based dynamic stabilization of the lumbar spine

被引:0
|
作者
Schauvliege, Hans [1 ]
Du Bois, Marc [1 ,2 ]
Verlooy, Jan [1 ,3 ]
机构
[1] Heilig Hartziekenhuis Mol, Dept Orthoped Surg, Gasthuisstr 1, B-2400 Mol, Belgium
[2] Antwerp Univ, Fac Med, Dept Social Med, Campus Drie Eiken,Univ Pl 1,DR 228, B-2610 Antwerp, Belgium
[3] Katholieke Univ Leuven, Fac Med, Dept Environm Hlth, Kapucijnenvoer 35 Blok D Bus 7001, B-3000 Leuven, Belgium
来源
ACTA ORTHOPAEDICA BELGICA | 2021年 / 87卷 / 01期
关键词
medical device; pedicle based dynamic stabilization; market authorization; failure; product liability; MEDICAL DEVICES; COMPLICATIONS; SYSTEM;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Pedicle-based dynamic stabilization (PBDS) devices such as Dynesy s are promoted as an alternative and less invasive option for rigid stabilization of one and even more levels of the lumbar spine. Promising features of the Dynesys system, as well as shortcomings, became obvious in several clinical studies. Since 2012, we started using a new PBDS device as an alternative for the Dynesys, to avoid the screw loosening and the kyphosing effect. The objective is to compare failure rates between the Dynesys and Balan-C type PBDS implant and factors affecting outcome. In a retrospective study we investigated a total of 90 patients with lumbar pedicle screw dynamic stabilization (a group of 64 patients with Dynesys stabilization is compared to a group of 26 patients with Balan-C stabilization). Mean follow-up was 48 and 38 months, respectively. Using logistic regression analysis the impact of baseline characteristics such as gender, age, body mass index (BMI), indication for surgery, primary or revision surgery, single versus more level surgery, surgeon's experience and type of the implant on implant failure was analyzed. We found a statistically significant difference in failure rates between the two systems (13% in the Dynesys group versus 62% in the Balan-C group). In multivariate analysis, type of implant was associated with implant failure (odds ratio : 13). Our current results call for an optimization of the pre-and post-marketing surveillance of pedicle-based dynamic stabilization.
引用
收藏
页码:191 / 196
页数:6
相关论文
共 50 条
  • [1] Pedicle Screw-based Posterior Dynamic Stabilization in the Lumbar Spine
    Lee, Michael J.
    Lindsey, Joshua D.
    Bransford, Richard J.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2010, 18 (10) : 581 - 588
  • [2] Posterior Pedicle Fixation-based Dynamic Stabilization Devices for the Treatment of Degenerative Diseases of the Lumbar Spine
    Bono, Christopher M.
    Kadaba, Murali
    Vaccaro, Alexander R.
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2009, 22 (05): : 376 - 383
  • [3] Dynamic stabilization of the lumbar spine
    Cakir, Balkan
    Richter, Marcus
    Huch, Klaus
    Puhl, Wolfhart
    Schmidt, Rene
    ORTHOPEDICS, 2006, 29 (08) : 716 - 722
  • [4] STABILIZATION OF THE LUMBAR SPINE WITH PEDICLE SCREWS AND STEFFEE PLATES
    KRAMER, FJK
    ABBINK, EP
    BOM, LPA
    ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (06): : 728 - 728
  • [5] A Review of Dynamic Stabilization in the Lumbar Spine
    Schroeder, Gregory D.
    Murray, Michael R.
    Hsu, Wellington K.
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2011, 21 (03) : 235 - 239
  • [6] Optimal stiffness of a pedicle-screw-based motion preservation implant for the lumbar spine
    Rohlmann, Antonius
    Zander, Thomas
    Bergmann, Georg
    Boustani, Hadi N.
    EUROPEAN SPINE JOURNAL, 2012, 21 (04) : 666 - 673
  • [7] Optimal stiffness of a pedicle-screw-based motion preservation implant for the lumbar spine
    Antonius Rohlmann
    Thomas Zander
    Georg Bergmann
    Hadi N. Boustani
    European Spine Journal, 2012, 21 : 666 - 673
  • [8] Minimally invasive pedicle-based non-fusion stabilization of the lumbar spine
    Lykissas, Marios G.
    Vasilikos, Ioannis
    Memtsoudis, Stavros G.
    Vougioukas, Vassilios
    JOURNAL OF NEUROSURGICAL SCIENCES, 2016, 60 (01) : 134 - 136
  • [9] A new lumbar fixation device alternative to pedicle-based stabilization for lumbar spine: In vitro cadaver investigation
    Gomleksiz, Cengiz
    Erbulut, Deniz Ufuk
    Can, Halil
    Kodigudla, Manoj Kumar
    Kelkar, Amey, V
    Kasapoglu, Eser
    Ozer, Ali Fahir
    Goel, Vijay K.
    JOURNAL OF SPINAL CORD MEDICINE, 2020, 43 (01): : 98 - 105
  • [10] Biomechanics of the lumbar spine after dynamic stabilization
    Bellini, Chiara Maria
    Galbusera, Fabio
    Raimondi, Manuela T.
    Mineo, Gittseppe V.
    Brayda-Bruno, Marco
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (06): : 423 - 429