Pulsed laser Doppler flowmetry for increased signal to noise ratio and probed depth

被引:0
|
作者
Steenbergen, W [1 ]
Kolkman, R [1 ]
Woldberg, S [1 ]
de Mul, F [1 ]
机构
[1] Univ Twente, Fac Sci & Technol, NL-7500 AE Enschede, Netherlands
关键词
Laser Doppler flowmetry; perfusion; microcirculation;
D O I
10.1117/12.478384
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In laser Doppler flowmetry (LDF) deep perfusion measurements can be realized by using a large separation between the fibers used for illumination and detection. In order to achieve a sufficient signal-to-noise ratio, the power of the laser light can be increased, but only to the limit indicated by the safety regulations. In this paper, pulsed laser Doppler flowmetry (pLDF) is presented as a manner to increase the SNR without exceeding the safety limits. The method is based on the principle that light is needed only when the signal is being sampled. The setup is presented, and we will show results that indicate that equivalent results are obtained for a pulsed and continuous wave setup (cwLDF), however with a much smaller tissue exposure. Furthermore, the limits encountered in realizing a pulsed system will be discussed.
引用
收藏
页码:49 / 54
页数:6
相关论文
共 50 条
  • [31] Signal to noise ratio estimates of ultrasound depth of penetration
    Shi, H
    Al-Sadah, J
    Mackie, T
    Zagzebski, J
    MEDICAL PHYSICS, 2003, 30 (06) : 1367 - 1367
  • [32] DEPTH OF TISSUE SAMPLING IN THE OPTIC-NERVE HEAD USING LASER DOPPLER FLOWMETRY
    KOELLE, JS
    RIVA, CE
    PETRIG, BL
    CRANSTOUN, SD
    LASERS IN MEDICAL SCIENCE, 1993, 8 (01) : 49 - 54
  • [33] The effect of digitisation on the signal-to-noise ratio of a pulsed radio signal
    Kouwenhoven, MLA
    Voûte, JLL
    ASTRONOMY & ASTROPHYSICS, 2001, 378 (02) : 700 - 709
  • [34] Comparison between pulsed laser and frequency-domain photoacoustic modalities: Signal-to-noise ratio, contrast, resolution, and maximum depth detectivity
    Lashkari, Bahman
    Mandelis, Andreas
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (09):
  • [35] A Coded Excitation Framework for Increased Signal-to-Noise Ratio of in Vivo Ultrasound Power Doppler Imaging
    Vienneau, Emelina P.
    Byram, Brett C.
    MEDICAL IMAGING 2021: ULTRASONIC IMAGING AND TOMOGRAPHY, 2021, 11602
  • [36] INVITRO COMPARISON OF DIFFERENT SIGNAL-PROCESSING ALGORITHMS USED IN LASER DOPPLER FLOWMETRY
    OBEID, AN
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 (01) : 43 - 52
  • [37] SIGNAL-TO-NOISE RATIOS OF LASER DOPPLER SIGNALS
    DURST, F
    HEIBER, KF
    OPTICA ACTA, 1977, 24 (01): : 43 - 67
  • [38] SIGNAL-TO-NOISE IMPROVEMENT IN LASER DOPPLER VELOCIMETRY
    LECONG, P
    LOVBERG, RH
    APPLIED OPTICS, 1980, 19 (24): : 4222 - 4225
  • [39] SIGNAL-TO-NOISE RATIO ENHANCEMENT THROUGH DOPPLER PROCESSING
    NEWHOUSE, VL
    AMIR, I
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1985, 32 (01): : 119 - 119
  • [40] Analysis of signal-to-noise ratio and heterodyne efficiency for reference-beam laser Doppler velocimeter
    Wei, Guo
    Zhou, Jian
    Long, Xingwu