Pulsed laser Doppler flowmetry for increased signal to noise ratio and probed depth

被引:0
|
作者
Steenbergen, W [1 ]
Kolkman, R [1 ]
Woldberg, S [1 ]
de Mul, F [1 ]
机构
[1] Univ Twente, Fac Sci & Technol, NL-7500 AE Enschede, Netherlands
关键词
Laser Doppler flowmetry; perfusion; microcirculation;
D O I
10.1117/12.478384
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In laser Doppler flowmetry (LDF) deep perfusion measurements can be realized by using a large separation between the fibers used for illumination and detection. In order to achieve a sufficient signal-to-noise ratio, the power of the laser light can be increased, but only to the limit indicated by the safety regulations. In this paper, pulsed laser Doppler flowmetry (pLDF) is presented as a manner to increase the SNR without exceeding the safety limits. The method is based on the principle that light is needed only when the signal is being sampled. The setup is presented, and we will show results that indicate that equivalent results are obtained for a pulsed and continuous wave setup (cwLDF), however with a much smaller tissue exposure. Furthermore, the limits encountered in realizing a pulsed system will be discussed.
引用
收藏
页码:49 / 54
页数:6
相关论文
共 50 条
  • [21] Laser Doppler velocimeter for vehicle application with improved signal-to-noise ratio
    Nie Xiaoming
    Zhou Jian
    Long Xingwu
    APPLIED PHYSICS B-LASERS AND OPTICS, 2014, 116 (03): : 637 - 641
  • [22] Estimation of Signal-to-Noise Ratio from Pulsed Coherent Doppler Lidar Measurements under Nonstationary Noise
    Smalikho, I. N.
    Banakh, V. A.
    Sherstobitov, A. M.
    ATMOSPHERIC AND OCEANIC OPTICS, 2024, 37 (03) : 373 - 381
  • [23] SIGNAL-PROCESSING TECHNIQUES FOR LOW SIGNAL-TO-NOISE RATIO LASER DOPPLER VELOCIMETRY SIGNALS
    SHINPAUGH, KA
    SIMPSON, RL
    WICKS, AL
    HA, SM
    FLEMING, JL
    EXPERIMENTS IN FLUIDS, 1992, 12 (4-5) : 319 - 328
  • [24] Pulsed-laser Doppler flowmetry provides basis for deep perfusion probing
    Kolkman, RGM
    Hondebrink, E
    Bolt, RA
    Steenbergen, W
    de Mul, FFM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (11): : 4242 - 4244
  • [26] On signal to noise ratio estimation in adaptive Doppler filters
    Papic, VD
    Kovacevic, BD
    Durovic, ZM
    TELSIKS 2001, VOL 1 & 2, PROCEEDINGS, 2001, : 69 - 72
  • [27] ON THE SIGNAL-TO-NOISE RATIO ENHANCEMENT OF THE DOPPLER PROCESS
    AMIR, I
    NEWHOUSE, VL
    ULTRASONICS, 1984, 22 (05) : 231 - 239
  • [28] Laser Doppler flowmetry in healthy rats: impact of isoflurane anesthetic on signal complexity
    Humeau, Anne
    Haussy, Bernard
    Fizanne, Lionel
    Roux, Jerome
    Asfar, Pierre
    Cales, Paul
    Rousseau, David
    Chapeau-Blondeau, Francois
    2008 MEDITERRANEAN CONFERENCE ON CONTROL AUTOMATION, VOLS 1-4, 2008, : 298 - +
  • [29] Digital Laser Doppler Flowmetry: Device, Signal Processing Technique, and Clinical Testing
    I. O. Kozlov
    E. A. Zherebtsov
    K. V. Podmasteryev
    A. V. Dunaev
    Biomedical Engineering, 2021, 55 : 12 - 16
  • [30] Digital Laser Doppler Flowmetry: Device, Signal Processing Technique, and Clinical Testing
    Kozlov, I. O.
    Zherebtsov, E. A.
    Podmasteryev, K., V
    Dunaev, A., V
    BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2021, 55 (01): : 12 - 16