GMP-Compliant Radiosynthesis of [18F]GP1, a Novel PET Tracer for the Detection of Thrombi

被引:6
|
作者
Hugenberg, Verena [1 ]
Zerna, Marion [2 ]
Berndt, Mathias [2 ]
Zabel, Reinhard [1 ]
Preuss, Rainer [1 ]
Rolfsmeier, Dirk [1 ]
Wegener, Janet [1 ]
Fox, Henrik [3 ,4 ]
Kassner, Astrid [5 ]
Milting, Hendrik [5 ]
Koglin, Norman [2 ]
Stephens, Andrew W. [2 ]
Gummert, Jan F. [4 ]
Burchert, Wolfgang [1 ]
Deutsch, Marcus-Andre [4 ]
机构
[1] Univ Bochum, Univ Hosp Ruhr, Heart & Diabet Ctr North Rhine Westphalia, Inst Radiol Nucl Med & Mol Imaging, Georg Str 11, D-32545 Bad Oeynhausen, Germany
[2] Life Mol Imaging GmbH, Tegeler Str 6-7, D-13353 Berlin, Germany
[3] Univ Bochum, Univ Hosp Ruhr, Heart & Diabet Ctr North Rhine Westphalia, Heart Failure Dept, Georg Str 11, D-32545 Bad Oeynhausen, Germany
[4] Univ Bochum, Univ Hosp Ruhr, Heart & Diabet Ctr North Rhine Westphalia, Dept Thorac & Cardiovasc Surg, Georg Str 11, D-32545 Bad Oeynhausen, Germany
[5] Univ Bochum, Univ Hosp Ruhr, Heart & Diabet Ctr North Rhine Westphalia, Dept Thorac & Cardiovasc Surg,Erich & Hanna Klesm, Georg Str 11, D-32545 Bad Oeynhausen, Germany
关键词
F-18]GP1; GMP compliant radiosynthesis; detection of thrombi; PET; CT imaging; BPVT; LVAD; thrombosis; SUBCLINICAL LEAFLET THROMBOSIS; BIOPROSTHETIC VALVES; TRANSCATHETER; F-18-GP1;
D O I
10.3390/ph14080739
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Thrombus formation and thromboembolic events play important roles in various cardiovascular pathologies. The key receptor involved in platelet aggregation is the fibrinogen receptor glycoprotein IIb/IIIa. [F-18]GP1, a derivative of the GPIIb/IIIa antagonist elarofiban, is a specific F-18-labeled small-molecule radiotracer that binds with high affinity to GPIIb/IIIa receptors of activated platelets. An improved, robust and fully automated radiosynthesis of [F-18]GP1 has been developed. [F-18]GP1 has been synthesized with decay corrected radiochemical yields of 38 +/- 6%, with a radiochemical concentration up to 1900 MBq/mL, molar activities of 952-9428 GBq/mu mol and a radio-chemical purity >98%. After determination of the optimal reaction conditions, in particular for HPLC separation, adaption of the reaction conditions to PET center requirements, validation of the manufacturing process and the quality control methods, the synthesis of [F-18]GP1 was successfully implemented to GMP standards and was available for clinical application. We describe the GMP-compliant synthesis of the novel radiotracer [F-18]GP1. Moreover, we provide some proof-of-concept examples for clinical application in the cardiovascular field. PET/CT with the novel small-molecular radiotracer [F-18]GP1 may serve as a novel highly sensitive tool for visualizing active platelet aggregation at the molecular level.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Optimised GMP-compliant production of [18F]DPA-714 on the Trasis AllinOne module
    Klaudia A. Cybulska
    Vera Bloemers
    Lars R. Perk
    Peter Laverman
    [J]. EJNMMI Radiopharmacy and Chemistry, 6
  • [22] Regarding "18F-GP1, a Novel PET Tracer Designed for High-Sensitivity, Low-Background Detection of Thrombi" REPLY
    Stephens, Andrew
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (02) : 351 - 351
  • [23] Radiosynthesis and evaluation of [18F]AFM, a selective PET tracer for the serotonin transporter.
    Huang, Y
    Bac, SA
    Zhu, Z
    Hwang, DR
    Narendran, R
    Talbot, PS
    Hackett, E
    Kegeles, LS
    Laruelle, M
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 358P - 358P
  • [24] Large-scale, GMP-compliant production and quality control of Al[18F]F-NOTA-Octreotide
    Kramer, V.
    Bispo, A.
    Gomez, C.
    Zouain, D.
    Cantuarias, L.
    Soza-Ried, C.
    Emmanuel, N.
    Decoux, G.
    Gameiro, C. Goncalves
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S222 - S222
  • [25] GMP-compliant automated synthesis of [18F]AV-45 (Florbetapir F 18) for imaging β-amyloid plaques in human brain
    Yao, Cheng-Hsiang
    Lin, Kun-Ju
    Weng, Chi-Chang
    Hsiao, Ing-Tsung
    Ting, Yi-Shu
    Yen, Tzu-Chen
    Jan, Tong-Rong
    Skovronsky, Daniel
    Kung, Mei-Ping
    Wey, Shiaw-Pyng
    [J]. APPLIED RADIATION AND ISOTOPES, 2010, 68 (12) : 2293 - 2297
  • [26] Automated radiosynthesis of GMP quality [18F]HX4 for PET imaging of hypoxia
    Turton, David R.
    Betts, Helen M.
    Dutton, David
    Perkins, Alan C.
    [J]. NUCLEAR MEDICINE AND BIOLOGY, 2015, 42 (05) : 494 - 498
  • [27] [18F]GP1 PET/CT in Patients with Prosthetic Valve Thrombosis - Diagnosis - Therapy - Follow up
    Hugenberg, V.
    Zabel, R.
    Preuss, R.
    Friedrichs, K.
    Rudolph, T.
    Koglin, N.
    Burchert, W.
    Deutsch, M.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S271 - S272
  • [28] Fully automated and GMP-compliant synthesis of [18F]JK-PSMA-7 on a Trasis AllinOne module
    Ermert, Johannes
    Krapf, Philipp
    Wicher, Thomas
    Zlatopolskiy, Boris
    Neumaier, Bernd
    [J]. NUCLEAR MEDICINE AND BIOLOGY, 2022, 108 : S124 - S124
  • [29] Production of [18F]F-Py-TFP as a secondary labelling precursor on a cassette based synthesis unit towards a GMP-compliant and convenient fluoroarylation of [18F]-peptides and [18F]-peptidomimetics
    Neels, O. C.
    Remde, Y.
    Schaefer, M.
    Burkert, D.
    Kopka, K.
    Cardinale, J.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S537 - S537
  • [30] Radiosynthesis of 1′-[18F]fluoroethyl-β-D-lactose ([18F]-FEL) for early detection of pancreatic carcinomas with PET
    Turkman, Nashaat
    Pal, Ashutosh
    Tong, William P.
    Gelovani, Juri G.
    Alauddin, Mian M.
    [J]. JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2011, 54 (05): : 233 - 238