X-ray computed tomography investigation of dilation of mineral-filled PVC under monotonic loading

被引:7
|
作者
Olufsen, Sindre Nordmark [1 ]
Clausen, Arild Holm [1 ]
Breiby, Dag Werner [2 ]
Hopperstad, Odd Sture [1 ]
机构
[1] Norwegian Univ Sci & Technol, NTNU, Dept Struct Engn, Struct Impact Lab SIMLab, NO-7491 Trondheim, Norway
[2] Norwegian Univ Sci & Technol, NTNU, Dept Phys, PoreLab, NO-7491 Trondheim, Norway
关键词
Polyvinyl chloride; PVC; X-ray computed tomography; Triaxiality; Strain rate; Digital image correlation; Tensile test; Volume change; STRAIN-RATE; BEHAVIOR; DEFORMATION; EVOLUTION; HDPE;
D O I
10.1016/j.mechmat.2019.103296
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The deformation-induced dilation of mineral-filled polyvinyl chloride (PVC) is investigated by means of polychromatic X-ray absorption tomography (XCT). Axisymmetric notched tensile specimens are strained to prescribed elongations using a tensile test apparatus and subsequently scanned by XCT after relaxation. During straining, surface deformations are quantified by digital image correlation (DIC) and contour tracking. The influence of stress triaxiality and strain rate on dilation is investigated by using tensile specimens with three different notch radii, all strained to three deformation levels at two different nominal strain rates. Pronounced reduction of density, corresponding to an increase of volume, is observed for all specimens in the XCT scans, but markedly different relative density distributions are measured for the three geometries. The accuracy of the polychromatic XCT density estimates is evaluated against data obtained with monochromatic synchrotron radiation computed tomography (sr-XCT), and a comparison to surface deformation-based dilation estimates is presented.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] USE OF THE METHOD OF X-RAY COMPUTED-TOMOGRAPHY FOR INVESTIGATING DAMAGES OF FILLED ELASTOMER
    KUROZAEV, VP
    PIMENOV, LA
    ADAMOV, AA
    SELIVANOV, EI
    [J]. SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1986, 22 (07): : 469 - 472
  • [32] Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging
    Chen, Dongmei
    Zhu, Shouping
    Chen, Xueli
    Chao, Tiantian
    Cao, Xu
    Zhao, Fengjun
    Huang, Liyu
    Liang, Jimin
    [J]. APPLIED PHYSICS LETTERS, 2014, 105 (19)
  • [33] A Mineral X-ray Linear Attenuation Coefficient Tool (MXLAC) to Assess Mineralogical Differentiation for X-ray Computed Tomography Scanning
    Bam, Lunga C.
    Miller, Jodie A.
    Becker, Megan
    [J]. MINERALS, 2020, 10 (05)
  • [34] Microscopic x-ray luminescence computed tomography
    Zhang, Wei
    Zhu, Dianwen
    Zhang, Kun
    Li, Changqing
    [J]. MULTIMODAL BIOMEDICAL IMAGING X, 2015, 9316
  • [35] Contemporary developments in computed X-ray tomography
    Seibert, JA
    [J]. RADIOLOGY, 1998, 209P : 207 - 208
  • [36] X-ray computed tomography in life sciences
    Shelley D. Rawson
    Jekaterina Maksimcuka
    Philip J. Withers
    Sarah H. Cartmell
    [J]. BMC Biology, 18
  • [37] X-ray computed tomography for medical imaging
    Hiriyannaiah, HP
    [J]. IEEE SIGNAL PROCESSING MAGAZINE, 1997, 14 (02) : 42 - 59
  • [38] X-ray luminescence computed tomography using a focused x-ray beam
    Zhang, Wei
    Lun, Michael C.
    Nguyen, Alex Anh-Tu
    Li, Changqing
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (11)
  • [39] X-ray computed tomography of ultralightweight metals
    Winter, JM
    Green, RE
    Waters, AM
    Green, WH
    [J]. RESEARCH IN NONDESTRUCTIVE EVALUATION, 1999, 11 (04) : 199 - 211
  • [40] STATISTICAL ASPECTS OF COMPUTED X-RAY TOMOGRAPHY
    CHESLER, DA
    PELC, NJ
    RIEDERER, SJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (01): : 130 - 131