Comparison of elution strength, column efficiency, and peak symmetry in subcritical water chromatography and traditional reversed-phase liquid chromatography

被引:26
|
作者
Kondo, T [1 ]
Yang, Y [1 ]
机构
[1] E Carolina Univ, Dept Chem, Greenville, NC 27858 USA
关键词
subcritical water chromatography; high-temperature water chromatography; temperature effect; RPLC; elution strength; column efficiency; peak symmetry;
D O I
10.1016/S0003-2670(03)00865-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, the elution strength of subcritical water has been investigated by matching the retention times of catechol, aniline, and pyridine using subcritical water, acetonitrile-ambient water, or methanol-ambient water mixtures as the eluent. Separations were performed on Chromatorex C-18, Zorbax RX-C-18, and poly(styrene-divinylbenzene) columns. The separation temperature ranged from 60 to 200 degreesC depending on columns used. It was found that a temperature rise of 40 degreesC for pure water mobile phase resulted in shortening retention time of at least the last eluting solute in each mixture by approximately 50%. The column efficiency study showed that subcritical water separation was more efficient than traditional separations using organic solvent-ambient water mixtures on the PRP-1 column. When temperature was increased, peak symmetry in subcritical water separation was mostly improved. This tendency was observed for separations on all three columns. (C) 2003 Published by Elsevier B.V.
引用
收藏
页码:157 / 166
页数:10
相关论文
共 50 条
  • [31] Improving reversed-phase liquid chromatography
    Jackson, PT
    Carr, PW
    CHEMTECH, 1998, 28 (10) : 29 - 37
  • [32] Reversed-phase liquid chromatography on a microspherical carbon column at high temperature
    Yamaki, S
    Isobe, T
    Okuyama, T
    Shinoda, T
    JOURNAL OF CHROMATOGRAPHY A, 1996, 728 (1-2) : 189 - 194
  • [33] Facilitated column selection in reversed-phase liquid chromatography for pharmaceutical separations
    Haghedooren, Erik
    Visky, Dora
    Dehouck, Pieter
    Koczian, Kristof
    Diana, Jose
    Kovacs, Zsuzsanna
    Noszal, Bela
    Hoogmartens, Jos
    Adams, Erwin
    LC GC EUROPE, 2007, 20 (02) : 82 - +
  • [35] Reversed-phase liquid chromatography column testing: robustness study of the test
    Le Mapihan, K
    Vial, J
    Jardy, A
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1061 (02) : 149 - 158
  • [36] Comparison of conventional microparticulate and a monolithic reversed-phase column for high-efficiency fast liquid chromatography of basic compounds
    McCalley, DV
    JOURNAL OF CHROMATOGRAPHY A, 2002, 965 (1-2) : 51 - 64
  • [37] Phase collapse in reversed-phase liquid chromatography
    Majors, RE
    LC GC NORTH AMERICA, 2002, 20 (06) : 516 - +
  • [38] A TRAPPING COLUMN FOR THE COUPLING OF REVERSED-PHASE LIQUID-CHROMATOGRAPHY AND CAPILLARY GAS-CHROMATOGRAPHY
    VREULS, JJ
    GOUDRIAAN, VP
    BRINKMAN, UAT
    DEJONG, GJ
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1991, 14 (07): : 475 - 480
  • [39] GRADIENT ELUTION IN LIQUID-CHROMATOGRAPHY .14. THEORY OF TERNARY GRADIENTS IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    JANDERA, P
    CHURACEK, J
    COLIN, H
    JOURNAL OF CHROMATOGRAPHY, 1981, 214 (01): : 35 - 46
  • [40] COMPARISON OF REVERSED-PHASE COLUMN MATERIALS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS
    VANDERZEE, R
    HOEKZEMA, T
    WELLINGWESTER, S
    WELLING, GW
    JOURNAL OF CHROMATOGRAPHY, 1986, 368 (02): : 283 - 289