Readout ASIC for 3D position-sensitive detectors

被引:35
|
作者
de Geronimo, Gianluigi [1 ]
Vernon, Emerson [1 ]
Ackley, Kim [1 ]
Dragone, Angelo [2 ]
Fried, Jack [1 ]
O'Connor, Paul [1 ]
He, Zhong [3 ]
Herman, Cedric
Zhang, Feng [3 ]
机构
[1] Brookhaven Natl Lab, Instrumentat Div, Upton, NY 11973 USA
[2] Brookhaven Natl Lab, Natl Synchrotron Light Source, Upton, NY 11973 USA
[3] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
关键词
application specific integrated circuit (ASIC); Cadmium-Zinc-Telluride (CZT); 3D; timing;
D O I
10.1109/TNS.2008.922217
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We describe an application specific integrated circuit (ASIC) for 3D position-sensitive detectors. It was optimized for pixelated Cadmium-Zinc-Telluride (CZT) sensors, and it measures, corresponding to an ionizing event, the energy and timing of signals from 121 anodes and one cathode. Each channel provides low-noise charge amplification, high-order shaping, along with peak- and timing-detection. The cathode's timing can be measured in three different ways: the first is based on multiple thresholds on the charge amplifier's voltage output; the second uses the threshold crossing of a fast-shaped signal; and the third measures the peak amplitude and timing from a bipolar shaper. With its power of 2 mW per channel the ASIC measures, on a CZT sensor connected and biased, charges up to 100 fC with an electronic resolution better than 200 e(-) rms. Our preliminary spectral measurements applying a simple cathode/anode ratio correction demonstrated a single-pixel resolution of 4.8 keV (0.72 %) at 662 keV, with the electronics and leakage current contributing in total with 2.1 keV.
引用
收藏
页码:1593 / 1603
页数:11
相关论文
共 50 条
  • [31] A QTC-based signal readout for position-sensitive multi-output detectors
    Zhou, Wei
    Zhang, Zhi-Ming
    Li, Dao-Wu
    Wang, Pei-Lin
    Feng, Bao-Tong
    Huang, Xian-Chao
    Hu, Ting-Ting
    Li, Xiao-Hui
    Chen, Yan
    Wang, Ying-Jie
    Liu, Yan-Tao
    Zhang, Yi-Wen
    Sun, Shi-Feng
    Gu, Xiao-Yue
    Yang, Ming-Jie
    Xiao, Xiong
    Wei, Long
    NUCLEAR SCIENCE AND TECHNIQUES, 2016, 27 (05)
  • [32] A QTC-based signal readout for position-sensitive multi-output detectors
    Wei Zhou
    Zhi-Ming Zhang
    Dao-Wu Li
    Pei-Lin Wang
    Bao-Tong Feng
    Xian-Chao Huang
    Ting-Ting Hu
    Xiao-Hui Li
    Yan Chen
    Ying-Jie Wang
    Yan-Tao Liu
    Yi-Wen Zhang
    Shi-Feng Sun
    Xiao-Yue Gu
    Ming-Jie Yang
    Xiong Xiao
    Long Wei
    Nuclear Science and Techniques, 2016, 27
  • [33] Gap measurement by position-sensitive detectors
    Kim, JK
    Kim, MS
    Bae, JH
    Kwon, JH
    Lee, HB
    Jeong, SH
    APPLIED OPTICS, 2000, 39 (16) : 2584 - 2591
  • [34] SEMICONDUCTOR POSITION-SENSITIVE DETECTORS.
    Radeka, V.
    Nuclear instruments and methods in physics research, 1983, 226 (01): : 209 - 218
  • [35] MULTIPURPOSE ARRAY OF POSITION-SENSITIVE DETECTORS
    OBST, AW
    BRAITHWA.WJ
    DOSS, CR
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (04): : 528 - 528
  • [36] Gap measurement by position-sensitive detectors
    Kim, Jung-Ki
    Kim, Man-Suhk
    Bae, Jong Han
    Kwon, Jin Hyuk
    Lee, Hang-Boo
    Jeong, Soo-Hoa
    Applied Optics, 2000, 39 (16): : 2584 - 2591
  • [37] POSITION-SENSITIVE SEMICONDUCTOR-DETECTORS
    LAEGSGAARD, E
    NUCLEAR INSTRUMENTS & METHODS, 1979, 162 (1-3): : 93 - 111
  • [38] FAST TIMING POSITION-SENSITIVE DETECTORS
    KLEIN, C
    TROTSCHER, J
    WOLLNIK, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 335 (1-2): : 146 - 147
  • [39] Noise analysis for position-sensitive detectors
    Narayanan, C
    Buckman, AB
    Busch-Vishniac, I
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1997, 46 (05) : 1137 - 1144
  • [40] POSITION-SENSITIVE DETECTORS AND WEISSENBERG DIFFRACTOMETERS
    PRINCE, E
    SANTORO, A
    ACTA CRYSTALLOGRAPHICA SECTION A, 1975, 31 : S234 - S234