Gap measurement by position-sensitive detectors

被引:37
|
作者
Kim, JK
Kim, MS
Bae, JH
Kwon, JH
Lee, HB
Jeong, SH
机构
[1] Yeungnam Univ, Dept Phys, Kyongsan 712749, South Korea
[2] LP PRC, Pyongtaek Si 451713, Kyunggi Do, South Korea
关键词
D O I
10.1364/AO.39.002584
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A system for measuring the gap in a proximity exposure tool of a plasma display panel (PDP) is developed that uses single or dual position-sensitive detectors (PSD's). The resolution of the gap distance is 0.5 mu m, with a capture range of 500 mu m. Signal processing is simple and fast and easy because analogous PSD's are used as the position sensors. One PSD is used to detect the position of the reference beam, which is reflected from the upper surface of the gap; the other PSD is used to detect the position of the signal beam, which is reflected from the lower surface of the gap. A charge-coupled-device sensor is also employed to monitor the reflected beams and the region of measurement. In the gap-measurement system that uses a single PSD, first the reference beam is incident upon the PSD and then the signal beam is incident upon the same PSD. Then the separation between the two beams is calculated from the position of the reference beam and from the average beam position. (C) 2000 Optical Society of America OCIS codes: 120.3930, 120.4640.
引用
收藏
页码:2584 / 2591
页数:8
相关论文
共 50 条
  • [1] Gap measurement by position-sensitive detectors
    Kim, Jung-Ki
    Kim, Man-Suhk
    Bae, Jong Han
    Kwon, Jin Hyuk
    Lee, Hang-Boo
    Jeong, Soo-Hoa
    [J]. Applied Optics, 2000, 39 (16): : 2584 - 2591
  • [2] POSITION-SENSITIVE DETECTORS
    HOBSON, PR
    WEBSDALE, DM
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (1-2): : R7 - R7
  • [3] Position-sensitive superconductor detectors
    Kurakado, M.
    Taniguchi, K.
    [J]. JOURNAL OF INSTRUMENTATION, 2016, 11
  • [4] POSITION-SENSITIVE PHOSWICH DETECTORS
    CHAN, Y
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 193 : 54 - NUCL
  • [5] POSITION-SENSITIVE GERMANIUM DETECTORS
    PROTIC, D
    RIEPE, G
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (01) : 553 - 555
  • [6] POSITION-SENSITIVE SCINTILLATION DETECTORS
    ROGERS, EH
    ARENS, JF
    WHITESIDE, H
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1974, 121 (03): : 599 - 604
  • [7] SEMICONDUCTOR POSITION-SENSITIVE DETECTORS
    RADEKA, V
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 226 (01): : 209 - 218
  • [8] SEMICONDUCTOR POSITION-SENSITIVE DETECTORS.
    Radeka, V.
    [J]. Nuclear instruments and methods in physics research, 1983, 226 (01): : 209 - 218
  • [9] MULTIPURPOSE ARRAY OF POSITION-SENSITIVE DETECTORS
    OBST, AW
    BRAITHWA.WJ
    DOSS, CR
    [J]. BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (04): : 528 - 528
  • [10] POSITION-SENSITIVE SEMICONDUCTOR-DETECTORS
    LAEGSGAARD, E
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1979, 162 (1-3): : 93 - 111