Gap measurement by position-sensitive detectors

被引:37
|
作者
Kim, JK
Kim, MS
Bae, JH
Kwon, JH
Lee, HB
Jeong, SH
机构
[1] Yeungnam Univ, Dept Phys, Kyongsan 712749, South Korea
[2] LP PRC, Pyongtaek Si 451713, Kyunggi Do, South Korea
关键词
D O I
10.1364/AO.39.002584
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A system for measuring the gap in a proximity exposure tool of a plasma display panel (PDP) is developed that uses single or dual position-sensitive detectors (PSD's). The resolution of the gap distance is 0.5 mu m, with a capture range of 500 mu m. Signal processing is simple and fast and easy because analogous PSD's are used as the position sensors. One PSD is used to detect the position of the reference beam, which is reflected from the upper surface of the gap; the other PSD is used to detect the position of the signal beam, which is reflected from the lower surface of the gap. A charge-coupled-device sensor is also employed to monitor the reflected beams and the region of measurement. In the gap-measurement system that uses a single PSD, first the reference beam is incident upon the PSD and then the signal beam is incident upon the same PSD. Then the separation between the two beams is calculated from the position of the reference beam and from the average beam position. (C) 2000 Optical Society of America OCIS codes: 120.3930, 120.4640.
引用
收藏
页码:2584 / 2591
页数:8
相关论文
共 50 条
  • [41] TIMING RESPONSE OF SILICON POSITION-SENSITIVE DETECTORS
    BENNETT, SJ
    ENGLAND, JBA
    FREER, M
    FULTON, BR
    MURGATROYD, JT
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 311 (1-2): : 105 - 112
  • [42] Position-sensitive low-temperature detectors
    Figueroa-Feliciano, E
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3): : 496 - 501
  • [43] USE OF POSITION-SENSITIVE DETECTORS IN POSITRON IMAGING
    MUEHLLEHNER, G
    COLSHER, JG
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1980, 27 (01) : 569 - 571
  • [44] NEW TYPE OF POSITION-SENSITIVE DETECTORS OF IONIZING RADIATION USING RISETIME MEASUREMENT
    BORKOWSKI, CJ
    KOPP, MK
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1968, 39 (10): : 1515 - +
  • [46] Measurement of shadow mask vibration and Q value using two position-sensitive detectors
    Bae, JH
    Kim, JK
    Kang, SG
    Nam, EH
    Kwon, JH
    Jeong, TY
    Shin, KM
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (01): : 216 - 220
  • [47] POSITION-SENSITIVE DETECTORS IN X-RAY ASTRONOMY
    CULHANE, JL
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (1-2): : 1 - 13
  • [48] New compact position-sensitive PMT for scintillation detectors
    Nagai, S.
    Watanabe, M.
    Shimoi, H.
    Liu, H.
    Yoshizawa, Y.
    [J]. IEEE Transactions on Nuclear Science, 1999, 46 (3 I): : 354 - 358
  • [49] NEW STRUCTURES FOR POSITION-SENSITIVE SEMICONDUCTOR-DETECTORS
    KEMMER, J
    LUTZ, G
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (2-3): : 588 - 598
  • [50] Multianode photomultipliers as position-sensitive detectors of single photons
    Korpar, S
    Krizan, P
    Pestotnik, R
    Gorisek, A
    Stanovnik, A
    Staric, M
    Skrk, D
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 442 (1-3): : 316 - 321