Design of a microfluidic device for comprehensive spatial two-dimensional liquid chromatography

被引:28
|
作者
Wouters, Bert [1 ]
De Vos, Jelle [1 ]
Desmet, Gert [1 ]
Terryn, Herman [2 ]
Schoenmakers, Peter J. [3 ]
Eeltink, Sebastiaan [1 ]
机构
[1] Vrije Univ Brussel, Dept Chem Engn, B-1050 Brussels, Belgium
[2] Vrije Univ Brussel, Dept Mat & Chem, B-1050 Brussels, Belgium
[3] Univ Amsterdam, Vant Hoff Inst Mol Sci, Amsterdam, Netherlands
关键词
Flow distributors; Peak-production rate; Polymer monoliths; Proteomics; MASS-SPECTROMETRY; GEL-ELECTROPHORESIS; PROTEIN SEPARATIONS; GRADIENT CONDITIONS; COLUMNS; FABRICATION; INTEGRATION; MIXTURES; CHANNELS; CHIPS;
D O I
10.1002/jssc.201401192
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study discusses the design aspects for the construction of a microfluidic device for comprehensive spatial two-dimensional liquid chromatography. In spatial two-dimensional liquid chromatography each peak is characterized by its coordinates in the plane. After completing the first-dimension separation all fractions are analyzed in parallel second-dimension separations. Hence, spatial two-dimensional liquid chromatography potentially provides much higher peak-production rates than a coupled column multi-dimensional liquid chromatography approach in which the second-dimension analyses are performed sequentially. A chip for spatial two-dimensional liquid chromatography has been manufactured from cyclic olefin copolymer and features a first-dimension separation channel and 21 parallel second-dimension separation channels oriented perpendicularly to the former. Compartmentalization of first- and second-dimension developments by physical barriers allowed for a preferential flow path with a minimal dispersion into the second-dimension separation channels. To generate a homogenous flow across all the parallel second-dimension channels, a radially interconnected flow distributor containing two zones of diamond-shaped pillars was integrated on-chip. A methacrylate ester based monolithic stationary phase with optimized macroporous structure was created in situ in the confines of the microfluidic chip. In addition, the use of a photomask was explored to localize monolith formation in the parallel second-dimension channels. Finally, to connect the spatial chip to the liquid chromatography instrument, connector ports were integrated allowing the use of Viper fittings. As an alternative, a chip holder with adjustable clasp locks was designed that allows the clamping force to be adjusted.
引用
收藏
页码:1123 / 1129
页数:7
相关论文
共 50 条
  • [41] Establishment and evaluation of comprehensive two-dimensional liquid chromatography (IEC/RP)
    Wang, ZC
    Zhang, QH
    Zhang, WB
    Li, T
    Zhao, ZY
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2005, 26 (03): : 426 - 429
  • [42] Comprehensive two-dimensional liquid chromatography of therapeutic monoclonal antibody digests
    Vanhoenacker, Gerd
    Vandenheede, Isabel
    David, Frank
    Sandra, Pat
    Sandra, Koen
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (01) : 355 - 366
  • [43] Construction of comprehensive two-dimensional liquid chromatography for the analysis of goat serum
    Wang, ZC
    Zhang, QG
    Zhang, WB
    Li, T
    Zhao, ZY
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (04) : 437 - 441
  • [44] Comprehensive two-dimensional liquid chromatography of therapeutic monoclonal antibody digests
    Gerd Vanhoenacker
    Isabel Vandenheede
    Frank David
    Pat Sandra
    Koen Sandra
    Analytical and Bioanalytical Chemistry, 2015, 407 : 355 - 366
  • [45] Characterization of hydroxypropylmethylcellulose (HPMC) using comprehensive two-dimensional liquid chromatography
    Greiderer, Andreas
    Steeneken, Linda
    Aalbers, Tom
    Vivo-Truyols, Gabriel
    Schoenmakers, Peter
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (34) : 5787 - 5793
  • [46] Characterization of sodium carboxymethyl cellulose by comprehensive two-dimensional liquid chromatography
    Shakun, Maria
    Heinze, Thomas
    Radke, Wolfgang
    CARBOHYDRATE POLYMERS, 2015, 130 : 77 - 86
  • [47] A protocol for designing comprehensive two-dimensional liquid chromatography separation systems
    Schoenmakers, Peter J.
    Vivo-Truyols, Gabriel
    Decrop, Wim M. C.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1120 (1-2) : 282 - 290
  • [48] Effect of sampling rate on resolution in comprehensive two-dimensional liquid chromatography
    Murphy, RE
    Schure, MR
    Foley, JP
    ANALYTICAL CHEMISTRY, 1998, 70 (08) : 1585 - 1594
  • [49] Comprehensive two-dimensional liquid chromatography to quantify polyphenols in red wines
    Dugo, Paola
    Cacciola, Francesco
    Donato, Paola
    Airado-Rodriguez, Diego
    Herrero, Miguel
    Mondello, Luigi
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (44) : 7483 - 7487
  • [50] Practical Approaches to Overcome the Challenges of Comprehensive Two-Dimensional Liquid Chromatography
    Pirok, Bob W. J.
    Schoenmakers, Peter J.
    LC GC EUROPE, 2018, 31 (05) : 242 - 249