Design of a microfluidic device for comprehensive spatial two-dimensional liquid chromatography

被引:28
|
作者
Wouters, Bert [1 ]
De Vos, Jelle [1 ]
Desmet, Gert [1 ]
Terryn, Herman [2 ]
Schoenmakers, Peter J. [3 ]
Eeltink, Sebastiaan [1 ]
机构
[1] Vrije Univ Brussel, Dept Chem Engn, B-1050 Brussels, Belgium
[2] Vrije Univ Brussel, Dept Mat & Chem, B-1050 Brussels, Belgium
[3] Univ Amsterdam, Vant Hoff Inst Mol Sci, Amsterdam, Netherlands
关键词
Flow distributors; Peak-production rate; Polymer monoliths; Proteomics; MASS-SPECTROMETRY; GEL-ELECTROPHORESIS; PROTEIN SEPARATIONS; GRADIENT CONDITIONS; COLUMNS; FABRICATION; INTEGRATION; MIXTURES; CHANNELS; CHIPS;
D O I
10.1002/jssc.201401192
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study discusses the design aspects for the construction of a microfluidic device for comprehensive spatial two-dimensional liquid chromatography. In spatial two-dimensional liquid chromatography each peak is characterized by its coordinates in the plane. After completing the first-dimension separation all fractions are analyzed in parallel second-dimension separations. Hence, spatial two-dimensional liquid chromatography potentially provides much higher peak-production rates than a coupled column multi-dimensional liquid chromatography approach in which the second-dimension analyses are performed sequentially. A chip for spatial two-dimensional liquid chromatography has been manufactured from cyclic olefin copolymer and features a first-dimension separation channel and 21 parallel second-dimension separation channels oriented perpendicularly to the former. Compartmentalization of first- and second-dimension developments by physical barriers allowed for a preferential flow path with a minimal dispersion into the second-dimension separation channels. To generate a homogenous flow across all the parallel second-dimension channels, a radially interconnected flow distributor containing two zones of diamond-shaped pillars was integrated on-chip. A methacrylate ester based monolithic stationary phase with optimized macroporous structure was created in situ in the confines of the microfluidic chip. In addition, the use of a photomask was explored to localize monolith formation in the parallel second-dimension channels. Finally, to connect the spatial chip to the liquid chromatography instrument, connector ports were integrated allowing the use of Viper fittings. As an alternative, a chip holder with adjustable clasp locks was designed that allows the clamping force to be adjusted.
引用
收藏
页码:1123 / 1129
页数:7
相关论文
共 50 条
  • [31] Flow Dynamics and Analyte Transfer in a Microfluidic Device for Spatial Two-Dimensional Separations
    Abdulhussain, Noor
    Fix, Raoul
    Nawada, Suhas
    Adamopoulou, Theodora
    Schoenmakers, Peter
    CHROMATOGRAPHIA, 2022, 85 (12) : 1041 - 1049
  • [32] Flow Dynamics and Analyte Transfer in a Microfluidic Device for Spatial Two-Dimensional Separations
    Noor Abdulhussain
    Raoul Fix
    Suhas Nawada
    Theodora Adamopoulou
    Peter Schoenmakers
    Chromatographia, 2022, 85 : 1041 - 1049
  • [33] Comprehensive Two-Dimensional Gas Chromatography
    Ryan, Danielle
    Marriott, Philip
    ADVANCES IN CHROMATOGRAPHY, VOL 46, 2008, 46 : 451 - 467
  • [34] Comprehensive two-dimensional gas chromatography
    Hinshaw, JV
    LC GC EUROPE, 2004, 17 (02) : 86 - +
  • [35] Comprehensive two-dimensional gas chromatography
    Hinshaw, JV
    LC GC NORTH AMERICA, 2004, 22 (01) : 32 - +
  • [36] Comprehensive two-dimensional gas chromatography
    Ryan, D
    Marriott, P
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (03) : 295 - 297
  • [37] Comprehensive two-dimensional gas chromatography
    Danielle Ryan
    Philip Marriott
    Analytical and Bioanalytical Chemistry, 2003, 376 : 295 - 297
  • [38] Comprehensive two-dimensional chromatography FOREWORD
    Ramos, Lourdes
    Tranchida, Peter Q.
    Schoenmakers, Peter
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1536 : 1 - 1
  • [39] Comprehensive two-dimensional liquid chromatography for the characterization of functional acrylate polymers
    Jiang, XL
    van der Horst, A
    Lima, V
    Schoenmakers, PJ
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1076 (1-2) : 51 - 61
  • [40] Comprehensive two-dimensional liquid chromatography for the separation of protonated and deuterated polystyrene
    Sinha, Pritish
    Harding, Gareth W.
    Maiko, Khumo
    Hiller, Wolf
    Pasch, Harald
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1265 : 95 - 104