Time-Resolved Interventional Cardiac C-arm Cone-Beam CT: An Application of the PICCS Algorithm

被引:70
|
作者
Chen, Guang-Hong [1 ]
Theriault-Lauzier, Pascal [1 ]
Tang, Jie [1 ]
Nett, Brian [1 ]
Leng, Shuai [1 ]
Zambelli, Joseph [1 ]
Qi, Zhihua [1 ]
Bevins, Nicholas [1 ]
Raval, Amish [2 ]
Reeder, Scott [3 ]
Rowley, Howard [3 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53792 USA
[2] Univ Wisconsin, Dept Med, Madison, WI 53792 USA
[3] Univ Wisconsin, Dept Radiol, Madison, WI 53792 USA
基金
加拿大自然科学与工程研究理事会; 美国国家卫生研究院;
关键词
Cardiac cone-beam CT; compressed sensing; high temporal resolution; interventional imaging; DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY; IMAGE-RECONSTRUCTION; LEFT ATRIUM; TEMPORAL RESOLUTION; CATHETER ABLATION; PULMONARY VEINS; ANGIOGRAPHY; PERFORMANCE; ESOPHAGUS;
D O I
10.1109/TMI.2011.2172951
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Time-resolved cardiac imaging is particularly interesting in the interventional setting since it would provide both image guidance for accurate procedural planning and cardiac functional evaluations directly in the operating room. Imaging the heart in vivo using a slowly rotating C-arm system is extremely challenging due to the limitations of the data acquisition system and the high temporal resolution required to avoid motion artifacts. In this paper, a data acquisition scheme and an image reconstruction method are proposed to achieve time-resolved cardiac cone-beam computed tomography imaging with isotropic spatial resolution and high temporal resolution using a slowly rotating C-arm system. The data are acquired within 14 s using a single gantry rotation with a short scan angular range. The enabling image reconstruction method is the prior image constrained compressed sensing (PICCS) algorithm. The prior image is reconstructed from data acquired over all cardiac phases. Each cardiac phase is then reconstructed from the retrospectively gated cardiac data using the PICCS algorithm. To validate the method, several studies were performed. Both numerical simulations using a hybrid motion phantom with static background anatomy as well as physical phantom studies have been used to demonstrate that the proposed method enables accurate reconstruction of image objects with a high isotropic spatial resolution. A canine animal model scanned in vivo was used to further validate the method.
引用
收藏
页码:907 / 923
页数:17
相关论文
共 50 条
  • [1] An Enhanced SMART-RECON Algorithm for Time-Resolved C-Arm Cone-Beam CT Imaging
    Li, Yinsheng
    Garrett, John W.
    Li, Ke
    Strother, Charles
    Chen, Guang-Hong
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (06) : 1894 - 1905
  • [2] Quantitative Blood Flow Imaging with Time-Resolved C-arm Cone-beam CT Imaging
    Garrett, John W.
    Li, Yinsheng
    Montoya, Juan
    Wu, Yijing
    Li, Ke
    Strother, Charles
    Chen, Guang-Hong
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [3] Time-Resolved Cone-Beam CT for Cardiac Interventions
    Lauzier, P. Theriault
    Tang, J.
    Chen, G-H
    MEDICAL PHYSICS, 2011, 38 (06) : 3760 - +
  • [4] Time-resolved cardiac interventional cone-beam CT reconstruction from fully truncated projections using the prior image constrained compressed sensing (PICCS) algorithm
    Lauzier, Pascal Theriault
    Tang, Jie
    Chen, Guang-Hong
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (09):
  • [5] C-Arm Cone-Beam CT: Principles and Applications
    Siewerdsen, J.
    Chen, G.
    MEDICAL PHYSICS, 2009, 36 (06) : 2716 - +
  • [6] Three-dimensional C-arm cone-beam CT: Applications in the interventional suite
    Wallace, Michael J.
    Kuo, Michael D.
    Glaiberman, Craig
    Binkert, Christoph A.
    Orth, Robert C.
    Soulez, Gilles
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (06) : 799 - 813
  • [7] Cone-beam reconstruction for a C-arm CT system
    Liu, X
    Defrise, M
    Desbat, L
    Fleute, M
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1489 - 1493
  • [8] C-arm cone-beam CT: General principles and technical considerations for use in interventional radiology
    Orth, Robert C.
    Wallace, Michael J.
    Kuo, Michael D.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (06) : 814 - 820
  • [9] High Temporal Resolution Time-Resolved C-arm Cone-beam CT Imaging using a Multi-Sweep Data Acquisition Scheme
    Li, Yinsheng
    Garrett, John W.
    Li, Ke
    Strother, Charles
    Chen, Guang-Hong
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [10] Method for Metal Artifact Avoidance in C-Arm Cone-Beam CT
    Wu, P.
    Sheth, N.
    Sisniega, A.
    Uneri, A.
    Han, R.
    Vijayan, R.
    Vagdargi, P.
    Kreher, B.
    Kunze, H.
    Kleinszig, G.
    Vogt, S.
    Lo, S. -F.
    Theodore, N.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312