Analytical evaluation of the new Beckman Coulter Access high sensitivity cardiac troponin I immunoassay

被引:5
|
作者
Lippi, Giuseppe [3 ]
Ferrari, Anna [1 ]
Gandini, Giorgio [2 ]
Gelati, Matteo [1 ]
Lo Cascio, Claudia [1 ]
Salvagno, Gian Luca [1 ]
机构
[1] Univ Verona, Sect Clin Biochem, Verona, Italy
[2] Univ Hosp Verona, Serv Transfus Med, Verona, Italy
[3] Univ Hosp Verona, Sect Clin Biochem, Ple Scuro 10, I-37314 Verona, Italy
关键词
immunoassay; method evaluation; myocardial infarction; troponin; ACUTE CORONARY SYNDROME; 99TH PERCENTILE; ASSAY; GENERATION; IMPRECISION; PERFORMANCE; ELEVATION; COHORT;
D O I
10.1515/cclm-2017-0350
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: This study was aimed to evaluate the analytical performance of the novel chemiluminescent and fully-automated Beckman Coulter Access hsTnI high-sensitivity immunoassay for measurement of cardiac troponin I (cTnI). Methods: The study, using lithium heparin samples, included assessment of limit of blank (LOB), limit of detection (LOD), functional sensitivity, linearity, imprecision (within run, between-run and total), calculation of 99th percentile upper reference limit (URL) in 175 healthy blood donors (mean age, 36 +/- 12 years; 47% women) and comparison with two other commercial cTnI immunoassays. Results: The LOB, LOD and functional sensitivity of Access hsTnI were 0.14, 0.34 and 1.35 ng/L, respectively. The within-run, between-run and total imprecision was 2.2%-2.9%, 4.6%-5.4%, and 5.4%-6.1%, respectively. The linearity was excellent in the range of cTnI values between 0.95 and 4195 ng/L (r = 1.00). The 99th percentile URL was 15.8 ng/L. Measurable cTnI values were found in 173/175 healthy subjects (98.9%). Good agreement of cTnI values was found with AccuTnI+3 (r = 0.97; mean bias, -9.3%), whereas less satisfactory agreement was found with Siemens Dimension Vista cTnI (r = 0.95; mean bias, -55%). Conclusions: The results of our evaluation of the Beckman Coulter Access hsTnI indicate that the analytical performance of this fully-automated immunoassay is excellent.
引用
收藏
页码:157 / 161
页数:5
相关论文
共 50 条
  • [21] Evaluation of the Beckman Coulter Access Procalcitonin Assay: analytical and clinical performance
    Choi, Hyunji
    Tashpulatova, Ziyoda
    Moon, Soo-Young
    Choi, Junghee
    Kim, Ji-Young
    Lee, Sun Min
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2022, 60 (02) : E50 - E53
  • [22] Analytical performance evaluation of novel high-sensitivity troponin I assay and other cardiac markers on Atellica immunoassay analyzer
    Park, M.
    Lee, N.
    Kang, H.
    Song, W.
    CLINICA CHIMICA ACTA, 2019, 493 : S179 - S179
  • [23] New generation cardiac troponin I assay for the access immunoassay system
    Venge, P
    Lindahl, B
    Wallentin, L
    CLINICAL CHEMISTRY, 2001, 47 (05) : 959 - 961
  • [24] Evaluation of the analytical performance of the Beckman Coulter Unicel DXI 800 Access Total 25(OH) Vitamin D immunoassay
    Topcuoglu, Canan
    Sezer, Sevilay
    Yilmaz, Fatma Meric
    Kosem, Arzu
    Ercan, Mujgan
    Turhan, Turan
    JOURNAL OF LABORATORY MEDICINE, 2018, 42 (05) : 205 - 211
  • [25] Comparison of the biosite triage MeterPlus and Abbott iSTAT cardiac troponin I analyzer to the Beckman Coulter DxI troponin I
    Tran, D. V.
    Cembrowski, G. S.
    Revers, C. W.
    Crawford, J. L.
    Zimmer, C. P.
    Simard, S. L.
    CLINICAL CHEMISTRY, 2007, 53 (06) : A215 - A215
  • [26] Analytical performance of the Access® TgAb II assay for the family of Access® immunoassay systems from beckman coulter.
    Holmes, D. R.
    Carollo-Neumann, C.
    Todtleben, J.
    Golden, W.
    Mattke, J.
    CLINICAL CHEMISTRY, 2007, 53 (06) : A196 - A197
  • [27] Analytical performance of a new free T3 assay on Beckman Coulter's family of Access® Immunoassay Systems
    Marquet, PY
    Bourdiec, S
    Candy, A
    Saye, M
    Guinde, N
    Ranchin, V
    CLINICAL CHEMISTRY, 2005, 51 : A226 - A226
  • [28] Cardiac troponin I measurement with the ACCESS® immunoassay system:: analytical and clinical performance characteristics
    Christenson, RH
    Apple, FS
    Morgan, DL
    Alonsozana, GL
    Mascotti, K
    Olson, M
    McCormack, RT
    Wians, FH
    Keffer, JH
    Duh, SH
    CLINICAL CHEMISTRY, 1998, 44 (01) : 52 - 60
  • [29] An Evaluation of the Analytical Performance of the New Beckman Coulter DxC 500i Clinical Analyzer
    Tran, B.
    Mindeman, L.
    Reyes, M.
    Kraght, P.
    Lynch, K.
    Meade, M.
    Frost, L.
    Rice, T.
    Cavalleri, M.
    Frost, S.
    CLINICAL CHEMISTRY, 2024, 70
  • [30] Analytical Performance of the VIDAS® High-Sensitivity Troponin I Assay and the Beckman Coulter Unicel® DXI AccuTnI+3 Assay in a Stat Laboratory
    Er, Tze-Kiong
    Su, Yu-Fa
    Chan, Tzu-Hsien
    CLINICAL LABORATORY, 2019, 65 (1-2) : 203 - 205