Evaluation of a Novel High-Intensity Focused Ultrasound Device for Ablating Subcutaneous Adipose Tissue for Noninvasive Body Contouring: Safety Studies in Human Volunteers

被引:47
|
作者
Gadsden, Ernesto [1 ]
Teresa Aguilar, Maria [1 ]
Smoller, Bruce R. [2 ]
Jewell, Mark L. [3 ]
机构
[1] Hosp Torre Med, Div Plast Surg, Mexico City, DF, Mexico
[2] Univ Arkansas, Ctr Med Sci, Little Rock, AR 72204 USA
[3] Oregon Hlth & Sci Univ, Eugene, OR USA
关键词
high-intensity focused ultrasound; HIFU; body contouring; histopathology; safety; LIPECTOMY;
D O I
10.1177/1090820X11405027
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: High-intensity focused ultrasound (HIFU) is an energy-based medical technology with many clinical applications. A device under clinical investigation in the United States (LipoSonix; Medicis Technologies Corporation, Bothell, Washington) uses HIFU to reduce localized deposits of abdominal adipose tissue. Objectives: The authors describe the results from their clinical trial investigating the safety of this HIFU device in human patients. Methods: Over the course of three studies evaluating the safety of the HIFU device for ablating human subcutaneous adipose tissue (SAT), 152 healthy patients were treated with total HIFU energy doses of 47 to 331 J/cm(2)), including patients who presented for elective abdominoplasty and underwent treatment to areas identified for subsequent excision. The safety of each treatment regimen was confirmed before the energy levels were raised. Abdominoplasty was performed up to 14 weeks following the HIFU procedure, and a pathologist performed histopathological analyses of excised tissues. Safety evaluations included an assessment of clinical chemistry and hematology profiles, physical examinations, and adverse events. Results: Posttreatment ultrasound confirmed that the HIFU effects were limited to targeted SAT layers. Histopathology revealed well-demarcated disruption of adipocytes within the targeted SAT. Phagocytosis of released lipids and cellular debris occurred after 14 to 28 days. Phagocytized lipids underwent normal hepatic metabolism. Healing progressed normally and was 95% complete after eight to 14 weeks. Adverse events consisted primarily of temporary treatment discomfort, edema, erythema, dysesthesia, and ecchymosis. There were no changes in clinical laboratory parameters, and no serious device-related adverse events occurred. Optimal clinical outcomes were achieved with lower energy levels, which provided beneficial effects with the least amount of discomfort. Conclusions: HIFU appears to provide a safe means for removing and remodeling unwanted deposits of abdominal SAT.
引用
下载
收藏
页码:401 / 410
页数:10
相关论文
共 50 条
  • [31] Localized Ablation of Thyroid Tissue by High-Intensity Focused Ultrasound: Improvement of Noninvasive Tissue Necrosis Methods
    Esnault, Olivier
    Franc, Brigitte
    Chapelon, Jean-Yves
    THYROID, 2009, 19 (10) : 1085 - 1091
  • [32] Evaluation of Safety Trial of High-Intensity Focused Ultrasound Therapy for Pancreatic Cancer
    Sofuni, Atsushi
    Moriyasu, Fuminori
    Sano, Takatomo
    Yamada, Kota
    Itokawa, Fumihide
    Tsuchiya, Takayoshi
    Kurihara, Toshio
    Tsuji, Shujiro
    Ishii, Kentaro
    Ikeuchi, Nobuhito
    Umeda, Junko
    Tanaka, Reina
    Itoi, Takao
    GASTROENTEROLOGY, 2011, 140 (05) : S392 - S392
  • [33] High-Intensity Focused Ultrasound Decreases Subcutaneous Fat Tissue Thickness by Increasing Apoptosis and Autophagy
    Byun, Kyung-A
    Park, Hyun Jun
    Oh, Seyeon
    Batsukh, Sosorburam
    Sun, Hye Jin
    Kim, Taehui
    Kim, Sunggeun
    Kang, Donghwan
    Son, Kuk Hui
    Byun, Kyunghee
    BIOMOLECULES, 2023, 13 (02)
  • [34] Invited Discussion on: Evidence-Based Efficacy of High-Intensity Focused Ultrasound (HIFU) in Aesthetic Body Contouring
    Shawn J. Loder
    J. Peter Rubin
    Aesthetic Plastic Surgery, 2021, 45 : 579 - 580
  • [35] Invited Discussion on: Evidence-Based Efficacy of High-Intensity Focused Ultrasound (HIFU) in Aesthetic Body Contouring
    Loder, Shawn J.
    Peter Rubin, J.
    AESTHETIC PLASTIC SURGERY, 2021, 45 (02) : 579 - 580
  • [36] INFLUENCE OF SKIN AND SUBCUTANEOUS TISSUE ON HIGH-INTENSITY FOCUSED ULTRASOUND BEAM: EXPERIMENTAL QUANTIFICATION AND NUMERICAL MODELING
    Grisey, Anthony
    Heidmann, Marc
    Letort, Veronique
    Lafitte, Pauline
    Yony, Sylvain
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (10): : 2457 - 2465
  • [37] Efficacy and safety of non-invasive body tightening with high-intensity focused ultrasound (HIFU)
    Ko, E. J.
    Hong, J. Y.
    Kwon, T. -R.
    Choi, E. J.
    Jang, Y. -J.
    Choi, S. Y.
    Yoo, K. H.
    Kim, S. Y.
    Kim, B. J.
    SKIN RESEARCH AND TECHNOLOGY, 2017, 23 (04) : 558 - 562
  • [38] Tightening effects of high-intensity focused ultrasound on body skin and subdermal tissue: a pilot study
    Choi, S. Y.
    No, Y. A.
    Kim, S. Y.
    Kim, B. J.
    Kim, M. N.
    JOURNAL OF THE EUROPEAN ACADEMY OF DERMATOLOGY AND VENEREOLOGY, 2016, 30 (09) : 1599 - 1602
  • [39] Association between adipose tissue thickness and fibroid shrinkage using ultrasound-guided high-intensity focused ultrasound
    Peiser, G. C. W.
    Jacobs, K.
    Spence, R. T.
    Setzen, R.
    SAJOG-SOUTH AFRICAN JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2020, 26 (03): : 94 - 98
  • [40] Pilot study: safety and effectiveness of simple ultrasound-guided high-intensity focused ultrasound ablating uterine leiomyoma with a diameter greater than 10 cm
    Hou, Ruijie
    Wang, Liwei
    Li, Shaoping
    Rong, Fengmin
    Wang, Yuanyuan
    Qin, Xuena
    Wang, Shijin
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1082):