Evaluation of a Novel High-Intensity Focused Ultrasound Device for Ablating Subcutaneous Adipose Tissue for Noninvasive Body Contouring: Safety Studies in Human Volunteers

被引:47
|
作者
Gadsden, Ernesto [1 ]
Teresa Aguilar, Maria [1 ]
Smoller, Bruce R. [2 ]
Jewell, Mark L. [3 ]
机构
[1] Hosp Torre Med, Div Plast Surg, Mexico City, DF, Mexico
[2] Univ Arkansas, Ctr Med Sci, Little Rock, AR 72204 USA
[3] Oregon Hlth & Sci Univ, Eugene, OR USA
关键词
high-intensity focused ultrasound; HIFU; body contouring; histopathology; safety; LIPECTOMY;
D O I
10.1177/1090820X11405027
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: High-intensity focused ultrasound (HIFU) is an energy-based medical technology with many clinical applications. A device under clinical investigation in the United States (LipoSonix; Medicis Technologies Corporation, Bothell, Washington) uses HIFU to reduce localized deposits of abdominal adipose tissue. Objectives: The authors describe the results from their clinical trial investigating the safety of this HIFU device in human patients. Methods: Over the course of three studies evaluating the safety of the HIFU device for ablating human subcutaneous adipose tissue (SAT), 152 healthy patients were treated with total HIFU energy doses of 47 to 331 J/cm(2)), including patients who presented for elective abdominoplasty and underwent treatment to areas identified for subsequent excision. The safety of each treatment regimen was confirmed before the energy levels were raised. Abdominoplasty was performed up to 14 weeks following the HIFU procedure, and a pathologist performed histopathological analyses of excised tissues. Safety evaluations included an assessment of clinical chemistry and hematology profiles, physical examinations, and adverse events. Results: Posttreatment ultrasound confirmed that the HIFU effects were limited to targeted SAT layers. Histopathology revealed well-demarcated disruption of adipocytes within the targeted SAT. Phagocytosis of released lipids and cellular debris occurred after 14 to 28 days. Phagocytized lipids underwent normal hepatic metabolism. Healing progressed normally and was 95% complete after eight to 14 weeks. Adverse events consisted primarily of temporary treatment discomfort, edema, erythema, dysesthesia, and ecchymosis. There were no changes in clinical laboratory parameters, and no serious device-related adverse events occurred. Optimal clinical outcomes were achieved with lower energy levels, which provided beneficial effects with the least amount of discomfort. Conclusions: HIFU appears to provide a safe means for removing and remodeling unwanted deposits of abdominal SAT.
引用
下载
收藏
页码:401 / 410
页数:10
相关论文
共 50 条
  • [21] High-Intensity Focused Ultrasound Effectively Reduces Waist Circumference by Ablating Adipose Tissue from the Abdomen and Flanks: A Retrospective Case Series
    Fatemi, Afschin
    Kane, Michael A. C.
    AESTHETIC PLASTIC SURGERY, 2010, 34 (05) : 577 - 582
  • [22] High-Intensity Focused Ultrasound Effectively Reduces Waist Circumference by Ablating Adipose Tissue from the Abdomen and Flanks: A Retrospective Case Series
    Afschin Fatemi
    Michael A. C. Kane
    Aesthetic Plastic Surgery, 2010, 34 : 577 - 582
  • [23] High-Intensity Focused Ultrasound Induces Adipogenesis via Control of Cilia in Adipose-Derived Stem Cells in Subcutaneous Adipose Tissue
    Oh, Seyeon
    Kim, Hyoung Moon
    Batsukh, Sosorburam
    Sun, Hye Jin
    Kim, Taehui
    Kang, Donghwan
    Son, Kuk Hui
    Byun, Kyunghee
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2022, 23 (16)
  • [24] High-Intensity Focused Electromagnetic (HIFEM) Energy With and Without Radiofrequency for Noninvasive Body Contouring: A Systematic Review
    Joshua Kohan
    Krishna Vyas
    Marios Erotocritou
    Ankur Khajuria
    Kevin Tehrani
    Aesthetic Plastic Surgery, 2024, 48 : 1156 - 1165
  • [25] Evidence-Based Efficacy of High-Intensity Focused Ultrasound (HIFU) in Aesthetic Body Contouring
    Bishara S. Atiyeh
    Fadl Chahine
    Aesthetic Plastic Surgery, 2021, 45 : 570 - 578
  • [26] Evidence-Based Efficacy of High-Intensity Focused Ultrasound (HIFU) in Aesthetic Body Contouring
    Atiyeh, Bishara S.
    Chahine, Fadl
    AESTHETIC PLASTIC SURGERY, 2021, 45 (02) : 570 - 578
  • [27] High-Intensity Focused Electromagnetic (HIFEM) Energy With and Without Radiofrequency for Noninvasive Body Contouring: A Systematic Review
    Kohan, Joshua
    Vyas, Krishna
    Erotocritou, Marios
    Khajuria, Ankur
    Tehrani, Kevin
    AESTHETIC PLASTIC SURGERY, 2024, 48 (06) : 1156 - 1165
  • [28] Safety Evaluation of High-Intensity Focused Ultrasound in Patients with Pancreatic Cancer
    Wang, Kun
    Zhu, Huili
    Meng, Zhiqiang
    Chen, Zhen
    Lin, Junhua
    Shen, Yehua
    Gao, Huifeng
    ONKOLOGIE, 2013, 36 (03): : 88 - 92
  • [29] Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
    Dupre, Aurelien
    Melodelima, David
    Perol, David
    Chen, Yao
    Vincenot, Jeremy
    Chapelon, Jean-Yves
    Rivoire, Michel
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2019, (143):
  • [30] Noninvasive body contouring by focused ultrasound: Safety and efficacy of the contour I device in a multicenter, controlled, clinical study
    Teitelbaum, Steven A.
    Burns, John L.
    Kubota, Junichiro
    Matsuda, Hidenori
    Otto, Morkel J.
    Shirakabe, Yukio
    Suzuki, Yoshiro
    Brown, Spencer A.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2007, 120 (03) : 779 - 789