Evaluation of a Novel High-Intensity Focused Ultrasound Device for Ablating Subcutaneous Adipose Tissue for Noninvasive Body Contouring: Safety Studies in Human Volunteers

被引:47
|
作者
Gadsden, Ernesto [1 ]
Teresa Aguilar, Maria [1 ]
Smoller, Bruce R. [2 ]
Jewell, Mark L. [3 ]
机构
[1] Hosp Torre Med, Div Plast Surg, Mexico City, DF, Mexico
[2] Univ Arkansas, Ctr Med Sci, Little Rock, AR 72204 USA
[3] Oregon Hlth & Sci Univ, Eugene, OR USA
关键词
high-intensity focused ultrasound; HIFU; body contouring; histopathology; safety; LIPECTOMY;
D O I
10.1177/1090820X11405027
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: High-intensity focused ultrasound (HIFU) is an energy-based medical technology with many clinical applications. A device under clinical investigation in the United States (LipoSonix; Medicis Technologies Corporation, Bothell, Washington) uses HIFU to reduce localized deposits of abdominal adipose tissue. Objectives: The authors describe the results from their clinical trial investigating the safety of this HIFU device in human patients. Methods: Over the course of three studies evaluating the safety of the HIFU device for ablating human subcutaneous adipose tissue (SAT), 152 healthy patients were treated with total HIFU energy doses of 47 to 331 J/cm(2)), including patients who presented for elective abdominoplasty and underwent treatment to areas identified for subsequent excision. The safety of each treatment regimen was confirmed before the energy levels were raised. Abdominoplasty was performed up to 14 weeks following the HIFU procedure, and a pathologist performed histopathological analyses of excised tissues. Safety evaluations included an assessment of clinical chemistry and hematology profiles, physical examinations, and adverse events. Results: Posttreatment ultrasound confirmed that the HIFU effects were limited to targeted SAT layers. Histopathology revealed well-demarcated disruption of adipocytes within the targeted SAT. Phagocytosis of released lipids and cellular debris occurred after 14 to 28 days. Phagocytized lipids underwent normal hepatic metabolism. Healing progressed normally and was 95% complete after eight to 14 weeks. Adverse events consisted primarily of temporary treatment discomfort, edema, erythema, dysesthesia, and ecchymosis. There were no changes in clinical laboratory parameters, and no serious device-related adverse events occurred. Optimal clinical outcomes were achieved with lower energy levels, which provided beneficial effects with the least amount of discomfort. Conclusions: HIFU appears to provide a safe means for removing and remodeling unwanted deposits of abdominal SAT.
引用
下载
收藏
页码:401 / 410
页数:10
相关论文
共 50 条
  • [1] EVALUATION OF HIGH-INTENSITY FOCUSED ULTRASOUND FOR THE REDUCTION OF SUBCUTANEOUS ADIPOSE TISSUE OF THE THIGHS
    Jewell, Mark
    Solish, Noel
    Struck, Steve
    VanDyke, Susan
    LASERS IN SURGERY AND MEDICINE, 2014, 46 : 32 - 32
  • [2] The clinical safety and histologic changes associated with the use of a novel high-intensity focused ultrasound device for noninvasive body sculpting
    Gadsden, Ernesto
    Smoller, Bruce
    Teresa Aguilar, Maria
    Jewell, Mark
    Glogau, Richard
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2010, 62 (03) : AB142 - AB142
  • [3] EFFICACY OF A HIGH-INTENSITY FOCUSED ULTRASOUND DEVICE FOR NON-INVASIVE BODY CONTOURING
    Shek, Samantha Y.
    Yeung, C. K.
    Chan, Johnny C. Y.
    Chan, Henry H. L.
    LASERS IN SURGERY AND MEDICINE, 2013, 45 : 22 - 22
  • [4] Efficacy and Safety of High-Intensity Focused Ultrasound for Noninvasive Abdominal Subcutaneous Fat Reduction
    Hong, Ji Yeon
    Ko, Eun Jung
    Choi, Sun Young
    Kwon, Tae-Rin
    Kim, Jong Hwan
    Kim, Soo Yeon
    Kim, Beom Joon
    DERMATOLOGIC SURGERY, 2020, 46 (02) : 213 - 219
  • [5] EVALUATION OF HIGH-INTENSITY FOCUSED ULTRASOUND FOR THE REDUCTION OF SUBCUTANEOUS ADIPOSE TISSUE USING MULTIPLE TREATMENT TECHNIQUES
    Robinson, Deanne Mraz
    Kaminer, Michael S.
    Baumann, Leslie
    Burns, A. Jay
    Geronemus, Roy G.
    Jewell, Mark
    Lupin, Mark
    Narurkar, Vic A.
    Struck, Steven K.
    Elford, Erica
    Dover, Jeffrey S.
    LASERS IN SURGERY AND MEDICINE, 2013, 45 : 21 - 21
  • [6] Evaluation of a novel device, high-intensity focused ultrasound with a contact cooling for subcutaneous fat reduction
    Lee, Heun Joo
    Lee, Mi-Hye
    Lee, Su Gun
    Yeo, Un-Cheol
    Chang, Sung Eun
    LASERS IN SURGERY AND MEDICINE, 2016, 48 (09) : 878 - 886
  • [7] Evaluation of a Novel High-Intensity Focused Ultrasound Device: Preclinical Studies in a Porcine Model
    Jewell, Mark L.
    Desilets, Charles
    Smoller, Bruce R.
    AESTHETIC SURGERY JOURNAL, 2011, 31 (04) : 429 - 434
  • [8] Safety and efficacy of a novel high-intensity focused electromagnetic technology device for noninvasive abdominal body shaping
    Jacob, Carolyn I.
    Paskova, Katya
    JOURNAL OF COSMETIC DERMATOLOGY, 2018, 17 (05) : 783 - 787
  • [9] Noninvasive surgery of prostate tissue by high-intensity focused ultrasound
    Sanghvi, NT
    Fry, FJ
    Bihrle, R
    Foster, RS
    Phillips, MH
    Syrus, J
    Zaitsev, AV
    Hennige, CW
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1996, 43 (06) : 1099 - 1110
  • [10] High-Intensity Focused Ultrasound for the Reduction of Subcutaneous Adipose Tissue Using Multiple Treatment Techniques
    Robinson, Deanne M.
    Kaminer, Michael S.
    Baumann, Leslie
    Burns, A. Jay
    Brauer, Jeremy A.
    Jewell, Mark
    Lupin, Mark
    Narurkar, Vic A.
    Struck, Steven K.
    Hledik, Jennifer
    Dover, Jeffrey S.
    DERMATOLOGIC SURGERY, 2014, 40 (06) : 641 - 651