Biomechanical comparison of interfragmentary compression in transverse fractures of the olecranon

被引:73
|
作者
Wilson, J.
Bajwa, A. [1 ]
Kamath, V. [2 ]
Rangan, A. [1 ]
机构
[1] James Cook Univ Hosp, Middlesbrough TS4 3BW, Cleveland, England
[2] Victoria Hosp, Blackpool FY3 8NR, Lancashire, England
来源
关键词
FIXATION METHODS;
D O I
10.1302/0301-620X.93B2.24613
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Compression and absolute stability are important in the management of intra-articular fractures. We compared tension band wiring with plate fixation for the treatment of fractures of the olecranon by measuring compression within the fracture. Identical transverse fractures were created in models of the ulna. Tension band wires were applied to ten fractures and ten were fixed with Acumed plates. Compression was measured using a Tekscan force transducer within the fracture gap. Dynamic testing was carried out by reproducing cyclical contraction of the triceps of 20 N and of the brachialis of 10 N. Both methods were tested on each sample. Paired t-tests compared overall compression and compression at the articular side of the fracture. The mean compression for plating was 819 N (SD 602, 95% confidence interval (CI)) and for tension band wiring was 77 N (SD 19, 95% CI) (p = 0.039). The mean compression on the articular side of the fracture for plating was 343 N (SD 276, 95% CI) and for tension band wiring was 1 N (SD 2, 95% CI) (p = 0.038). During simulated movements, the mean compression was reduced in both groups, with tension band wiring at -14 N (SD 7) and for plating -173 N (SD 32). No increase in compression on the articular side was detected in the tension band wiring group. Pre-contoured plates provide significantly greater compression than tension bands in the treatment of transverse fractures of the olecranon, both over the whole fracture and specifically at the articular side of the fracture. In tension band wiring the overall compression was reduced and articular compression remained negligible during simulated contraction of the triceps, challenging the tension band principle.
引用
收藏
页码:245 / 250
页数:6
相关论文
共 50 条
  • [11] Biomechanical comparison of the new cross-locking intramedullary nail with tension band wiring for transverse olecranon fractures
    Liang, Cheng
    Li, Chun-Yan
    Qin, Xiao-Shuai
    Wang, Guan
    Duan, Ke
    Lu, Xiao-Bo
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 : S95 - S100
  • [12] Biomechanical Comparison of Cortical Lag Screws and Cortical Position Screws for Their Generation of Interfragmentary Compression and Area of Compression in Simulated Lateral Humeral Condylar Fractures
    Fuchter, Lucy M.
    Wills, Dan
    Walsh, William R.
    Newman, Mark
    Tan, Chris
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2023, 36 (05) : 250 - 256
  • [13] Biomechanical evaluation of intramedullary nail versus tension band fixation for transverse olecranon fractures
    Molloy, S
    Jasper, LE
    Elliott, DS
    Brumback, RJ
    Belkoff, SM
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (03) : 170 - 174
  • [14] COMPRESSION OSTEOSYNTHESIS IN FRACTURES OF OLECRANON
    SRIVASTAVA, KP
    VARSHNEY, AK
    SINGH, CP
    INTERNATIONAL SURGERY, 1978, 63 (01) : 20 - 22
  • [15] Fixation of Transverse Olecranon Fractures by Suture Bridge Method Using Suture Anchor: Biomechanical Comparison with Tension Band Wiring Technique
    Lee, Hyun Il
    Cho, Jin Ho
    Choi, Jun Young
    Lee, Sung Sahn
    Cho, Sung Tan
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2021, 26 (04): : 563 - 570
  • [16] Biomechanical studies on transverse olecranon and patellar fractures: a systematic review with the development of a new scoring method
    Traa, Willeke A.
    Oomen, Pim J. A.
    den Hamer, Anniek
    Heusinkveld, Maarten H. G.
    Maffulli, Nicola
    BRITISH MEDICAL BULLETIN, 2013, 108 (01) : 131 - 157
  • [17] A biomechanical comparison of multidirectional nail and locking plate fixation in unstable olecranon fractures
    Argintar, Evan
    Martin, Benjamin D.
    Singer, Andrea
    Hsieh, Adam H.
    Edwards, Scott
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (10) : 1398 - 1405
  • [18] Biomechanical comparison of fixation methods in transverse patella fractures
    Scilaris, TA
    Grantham, JL
    Prayson, MJ
    Marshall, MP
    Hamilton, JJ
    Williams, JL
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1998, 12 (05) : 356 - 359
  • [19] Olecranon fractures repaired with FiberWire or metal wire tension banding: A biomechanical comparison
    Carofino, Bradley C.
    Santangelo, Stephen A.
    Kabadi, Mitesh
    Mazzocca, Augustus D.
    Browner, Bruce D.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (09): : 964 - 970
  • [20] REPAIR OF FEMORAL HEAD AND NECK FRACTURES BY INTERFRAGMENTARY COMPRESSION
    NUNAMAKER, DM
    JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 1973, 162 (07): : 569 - 572