Biomechanical comparison of interfragmentary compression in transverse fractures of the olecranon

被引:73
|
作者
Wilson, J.
Bajwa, A. [1 ]
Kamath, V. [2 ]
Rangan, A. [1 ]
机构
[1] James Cook Univ Hosp, Middlesbrough TS4 3BW, Cleveland, England
[2] Victoria Hosp, Blackpool FY3 8NR, Lancashire, England
来源
关键词
FIXATION METHODS;
D O I
10.1302/0301-620X.93B2.24613
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Compression and absolute stability are important in the management of intra-articular fractures. We compared tension band wiring with plate fixation for the treatment of fractures of the olecranon by measuring compression within the fracture. Identical transverse fractures were created in models of the ulna. Tension band wires were applied to ten fractures and ten were fixed with Acumed plates. Compression was measured using a Tekscan force transducer within the fracture gap. Dynamic testing was carried out by reproducing cyclical contraction of the triceps of 20 N and of the brachialis of 10 N. Both methods were tested on each sample. Paired t-tests compared overall compression and compression at the articular side of the fracture. The mean compression for plating was 819 N (SD 602, 95% confidence interval (CI)) and for tension band wiring was 77 N (SD 19, 95% CI) (p = 0.039). The mean compression on the articular side of the fracture for plating was 343 N (SD 276, 95% CI) and for tension band wiring was 1 N (SD 2, 95% CI) (p = 0.038). During simulated movements, the mean compression was reduced in both groups, with tension band wiring at -14 N (SD 7) and for plating -173 N (SD 32). No increase in compression on the articular side was detected in the tension band wiring group. Pre-contoured plates provide significantly greater compression than tension bands in the treatment of transverse fractures of the olecranon, both over the whole fracture and specifically at the articular side of the fracture. In tension band wiring the overall compression was reduced and articular compression remained negligible during simulated contraction of the triceps, challenging the tension band principle.
引用
收藏
页码:245 / 250
页数:6
相关论文
共 50 条
  • [1] Biomechanical comparison of continuous compression implants versus tension band fixation for transverse olecranon fractures
    Moon, Morgan
    Schweser, Kyle
    Bezold, Will
    Cook, James L.
    JOURNAL OF ORTHOPAEDICS, 2022, 34 : 316 - 321
  • [2] Transverse fractures of the olecranon: a biomechanical comparison of three fixation techniques
    Hassan Sadri
    Richard Stern
    Michael Singh
    Berend Linke
    Pierre Hoffmeyer
    Karsten Schwieger
    Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 131 - 138
  • [3] Transverse fractures of the olecranon: a biomechanical comparison of three fixation techniques
    Sadri, Hassan
    Stern, Richard
    Singh, Michael
    Linke, Berend
    Hoffmeyer, Pierre
    Schwieger, Karsten
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (01) : 131 - 138
  • [4] Biomechanical comparison of fixation methods in transverse olecranon fractures: A cadaveric study
    Prayson, MJ
    Williams, JL
    Marshall, MP
    Scilaris, TA
    Lingenfelter, EJ
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (08) : 565 - 572
  • [5] Biomechanical comparison of tension band- and interfragmentary screw fixation with a new implant in transverse patella fractures
    Dargel, J.
    Gick, S.
    Mader, K.
    Koebke, J.
    Pennig, D.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (02): : 156 - 160
  • [6] Comparison of interfragmentary compression in conventional and locked plating of proximal unicondylar tibia fractures : A biomechanical cadaver study
    Rahm, Stefan
    Ebneter, Lukas
    Schultz, Birte
    Spross, Christian
    Kulling, Fabrice
    Erhardt, Johannes B.
    ACTA ORTHOPAEDICA BELGICA, 2016, 82 (03): : 586 - 592
  • [7] Biomechanical comparison of tension band wiring and plate fixation with locking screws in transverse olecranon fractures
    Midtgaard, Kaare Sourin
    Soreide, Endre
    Brattgjerd, Jan Egil
    Moatshe, Gilbert
    Madsen, Jan Erik
    Flugsrud, Gunnar B.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (06) : 1242 - 1248
  • [8] New tension band material for fixation of transverse olecranon fractures: A biomechanical study
    Lalonde, JA
    Rabalais, RD
    Mansour, A
    Burger, EL
    Riemer, BL
    Lu, Y
    Baratta, RV
    ORTHOPEDICS, 2005, 28 (10) : 1191 - 1194
  • [9] Biomechanical comparison of the new cross-locking intramedullary nail with tension band wiring for transverse olecranon fractures
    Liang, Cheng
    Li, Chun-Yan
    Qin, Xiao-Shuai
    Wang, Guan
    Duan, Ke
    Lu, Xiao-Bo
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 : S95 - S100
  • [10] Biomechanical comparison of various bone reduction forceps in interfragmentary compression and area of compression in an experimental model of canine lateral humeral condylar fractures
    Baskette, Madison
    Ferrigno, Cassio Ricardo Auada
    PLOS ONE, 2025, 20 (02):