Binocular Visual Simulation of a Corneal Inlay to Increase Depth of Focus

被引:45
|
作者
Tabernero, Juan [1 ]
Schwarz, Christina [1 ]
Fernandez, Enrique J. [1 ]
Artal, Pablo [1 ]
机构
[1] Univ Murcia, Lab Opt, Inst Univ Invest Opt & Nanofis, E-30100 Murcia, Spain
关键词
SURGICAL-CORRECTION; LIQUID-CRYSTAL; HUMAN EYE; PRESBYOPIA; ABERRATIONS; PERFORMANCE; SENSOR; LENSES;
D O I
10.1167/iovs.10-6436
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To investigate binocular visual acuity and depth of focus when one eye forms images through a typical pupil diameter aperture (4 mm) and the other eye through a small pupil of 1.5-mm diameter. METHODS. Using a recently developed adaptive optics binocular visual simulator, through focus monocular and binocular visual acuity were measured in three subjects under specially simulated visual conditions: right eyes had "small aperture" vision through a 1.5-mm pupil diameter and left eyes had normal vision through 4-mm pupil diameter. The measurements were performed in photopic and mesopic conditions. RESULTS. An increase in binocular and monocular (for the small-aperture eye) depth of focus was measured with respect to the 4-mm pupil diameter eye. It ranged from 1 to 1.5 diopter (D) depending on the threshold requirement and the visibility conditions. For photopic conditions, the J2 visual acuity level was reached at 1 D of defocus for the 4-mm pupil diameter case, while for the 1.5-mm, the J2 level was reached at 2.5 D. Binocular summation occurred only in far vision conditions (no defocus added). For near vision, binocular visual acuity closely followed the values of monocular visual acuity for the eye with the smaller aperture. CONCLUSIONS. The small-aperture effect to increase depth of focus in the human eye was successfully implemented in a binocular visual simulator. Although certain limitations exist, the small-aperture approach provided a simple but attractive solution to increase depth of focus in the human eye. (Invest Ophthalmol Vis Sci. 2011; 52:5273-5277) DOI: 10.1167/iovs.10-6436
引用
收藏
页码:5273 / 5277
页数:5
相关论文
共 50 条
  • [41] Evaluation of visual evoked potential binocular summation after corneal refractive surgery
    Amini Vishteh, Rasoul
    Mirzajani, Ali
    Jafarzadehpur, Ebrahim
    Taghieh, Abolghasem
    DOCUMENTA OPHTHALMOLOGICA, 2020, 140 (02) : 181 - 188
  • [42] Evaluation of visual evoked potential binocular summation after corneal refractive surgery
    Rasoul Amini Vishteh
    Ali Mirzajani
    Ebrahim Jafarzadehpur
    Abolghasem Taghieh
    Documenta Ophthalmologica, 2020, 140 : 181 - 188
  • [43] Through-focus performance with a corneal shape-changing inlay: One-year results
    Whitman, Jeffrey
    Hovanesian, John
    Steinert, Roger F.
    Koch, Douglas
    Potvin, Richard
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (07): : 965 - 971
  • [44] Retrospective Comparison of Visual Outcomes After KAMRA Corneal Inlay Implantation With Simultaneous PRK or LASIK
    Moshirfar, Majid
    Bean, Andrew E.
    Albarracin, Julio C.
    Rebenitsch, Ronald L.
    Wallace, Ryan T.
    Birdsong, Orry C.
    JOURNAL OF REFRACTIVE SURGERY, 2018, 34 (05) : 310 - +
  • [45] SIX-MONTH POSTOPERATIVE VISUAL PERFORMANCE OF AMETROPIC PREBYOPIC PATIENTS IMPLANTED WITH A CORNEAL INLAY
    Kent, David
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 : 102 - 103
  • [46] VISUAL DEPTH OF FOCUS MEASURED FOR VARIOUS COLORED DISPLAYS
    RONCHI, LR
    DIFRAIA, L
    COLOR RESEARCH AND APPLICATION, 1986, 11 : S52 - S56
  • [47] Multifocal Displays, Diffractive Depth of Focus, and Visual Comfort
    Kovalev, A. M.
    OPTOELECTRONICS INSTRUMENTATION AND DATA PROCESSING, 2010, 46 (03) : 274 - 281
  • [48] DEPTH OF FOCUS, EYE SIZE AND VISUAL-ACUITY
    GREEN, DG
    POWERS, MK
    BANKS, MS
    VISION RESEARCH, 1980, 20 (10) : 827 - 835
  • [49] DEPTH OF FOCUS, EYE SIZE, AND VISUAL-ACUITY
    POWERS, MK
    GREEN, DG
    BANKS, MS
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1978, 68 (10) : 1427 - 1427
  • [50] Impact of spherical aberration on visual quality and depth of focus
    Holladay, Jack T.
    Kozhaya, Karim
    Koch, Douglas D.
    Wang, Li
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (06): : 651 - 652