Binocular Visual Simulation of a Corneal Inlay to Increase Depth of Focus

被引:45
|
作者
Tabernero, Juan [1 ]
Schwarz, Christina [1 ]
Fernandez, Enrique J. [1 ]
Artal, Pablo [1 ]
机构
[1] Univ Murcia, Lab Opt, Inst Univ Invest Opt & Nanofis, E-30100 Murcia, Spain
关键词
SURGICAL-CORRECTION; LIQUID-CRYSTAL; HUMAN EYE; PRESBYOPIA; ABERRATIONS; PERFORMANCE; SENSOR; LENSES;
D O I
10.1167/iovs.10-6436
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To investigate binocular visual acuity and depth of focus when one eye forms images through a typical pupil diameter aperture (4 mm) and the other eye through a small pupil of 1.5-mm diameter. METHODS. Using a recently developed adaptive optics binocular visual simulator, through focus monocular and binocular visual acuity were measured in three subjects under specially simulated visual conditions: right eyes had "small aperture" vision through a 1.5-mm pupil diameter and left eyes had normal vision through 4-mm pupil diameter. The measurements were performed in photopic and mesopic conditions. RESULTS. An increase in binocular and monocular (for the small-aperture eye) depth of focus was measured with respect to the 4-mm pupil diameter eye. It ranged from 1 to 1.5 diopter (D) depending on the threshold requirement and the visibility conditions. For photopic conditions, the J2 visual acuity level was reached at 1 D of defocus for the 4-mm pupil diameter case, while for the 1.5-mm, the J2 level was reached at 2.5 D. Binocular summation occurred only in far vision conditions (no defocus added). For near vision, binocular visual acuity closely followed the values of monocular visual acuity for the eye with the smaller aperture. CONCLUSIONS. The small-aperture effect to increase depth of focus in the human eye was successfully implemented in a binocular visual simulator. Although certain limitations exist, the small-aperture approach provided a simple but attractive solution to increase depth of focus in the human eye. (Invest Ophthalmol Vis Sci. 2011; 52:5273-5277) DOI: 10.1167/iovs.10-6436
引用
收藏
页码:5273 / 5277
页数:5
相关论文
共 50 条
  • [21] Binocular accommodative response with extended depth of focus under controlled convergences
    Lyu, Jiakai
    Ng, Cherlyn J.
    Bang, Seung Pil
    Yoon, Geunyoung
    JOURNAL OF VISION, 2021, 21 (08): : 1 - 12
  • [22] Visual performance with an extended depth of focus contact lens for myopia control and corneal topography in assessing lens centration
    Rizzo, G. C.
    Borghesi, A.
    Di Vizio, A.
    Zeri, F.
    Ponzini, E.
    Tavazzi, S.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2023, 46 (05):
  • [23] Evaluating the small aperture intraocular lens: depth of focus and the role of refraction and preoperative corneal astigmatism in visual performance
    Vukich, John
    Thompson, Vance
    Yeu, Elizabeth
    Wiley, William F.
    Bafna, Shamik
    Koch, Douglas D.
    Lin, Ling
    Michna, Magda
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (11): : 1165 - 1172
  • [24] The impact of different corneal refractive surgeries on binocular dynamic visual acuity
    Wang, Yuexin
    Guo, Yining
    Li, Yuanting
    Zhang, Yu
    Yuan, Yifei
    Wu, Tingyi
    Chen, Yueguo
    Li, Xuemin
    FRONTIERS IN NEUROSCIENCE, 2023, 17
  • [25] Visual Outcomes and Safety of a Small Diameter Intrastromal Refractive Inlay for the Corneal Compensation of Presbyopia
    Bouzoukis, Dimitrios I.
    Kymionis, George D.
    Panagopoulou, Sophia I.
    Diakonis, Vasilios F.
    Pallikaris, Aristophanes I.
    Limnopoulou, Aliki N.
    Portaliou, Dimitra M.
    Pallikaris, Ioannis G.
    JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (03) : 168 - U92
  • [26] Effect of small aperture intra-corneal inlay on peripheral kinetic visual fields
    Brooker, Eric
    Vilupuru, Abhiram
    Waring, George
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [27] Visual Outcomes and Safety of a Refractive Corneal Inlay for Presbyopia: One-Year Results
    Kohnen, Thomas
    Lwowski, Christoph
    Bohm, Myriam
    Hemkeppler, Eva
    Jandewerth, Tyll
    JOURNAL OF REFRACTIVE SURGERY, 2024, 40 (01) : E1 - E9
  • [28] Explantation of KAMRA Corneal Inlay: 10-Year Occurrence and Visual Outcome Analysis
    Moshirfar, Majid
    Lau, Chap-Kay
    Chartrand, Nicholas A.
    Parsons, Mark T.
    Stapley, Seth
    Bundogji, Nour
    Ronquillo, Yasmyne C.
    Linn, Steven H.
    Hoopes, Phillip C.
    CLINICAL OPHTHALMOLOGY, 2022, 16 : 3327 - 3337
  • [29] Effect of pupil size on visual performance of presbyopes with small-aperture corneal inlay
    Vilupuru, Srividhya
    Lin, Ling
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [30] Clinical results after binocular implantation of a unique nondiffractive enhanced monofocal intraocular lens designed for enhanced monovision to increase the depth of focus
    Madhivanan, Nivean
    Nivean, Pratheeba D.
    Madanagopalan, V. G.
    Priya, Shanmuga
    Madhivanan, Nishanth
    Arthi, M.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (01) : 63 - 65