Binocular Visual Simulation of a Corneal Inlay to Increase Depth of Focus

被引:45
|
作者
Tabernero, Juan [1 ]
Schwarz, Christina [1 ]
Fernandez, Enrique J. [1 ]
Artal, Pablo [1 ]
机构
[1] Univ Murcia, Lab Opt, Inst Univ Invest Opt & Nanofis, E-30100 Murcia, Spain
关键词
SURGICAL-CORRECTION; LIQUID-CRYSTAL; HUMAN EYE; PRESBYOPIA; ABERRATIONS; PERFORMANCE; SENSOR; LENSES;
D O I
10.1167/iovs.10-6436
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To investigate binocular visual acuity and depth of focus when one eye forms images through a typical pupil diameter aperture (4 mm) and the other eye through a small pupil of 1.5-mm diameter. METHODS. Using a recently developed adaptive optics binocular visual simulator, through focus monocular and binocular visual acuity were measured in three subjects under specially simulated visual conditions: right eyes had "small aperture" vision through a 1.5-mm pupil diameter and left eyes had normal vision through 4-mm pupil diameter. The measurements were performed in photopic and mesopic conditions. RESULTS. An increase in binocular and monocular (for the small-aperture eye) depth of focus was measured with respect to the 4-mm pupil diameter eye. It ranged from 1 to 1.5 diopter (D) depending on the threshold requirement and the visibility conditions. For photopic conditions, the J2 visual acuity level was reached at 1 D of defocus for the 4-mm pupil diameter case, while for the 1.5-mm, the J2 level was reached at 2.5 D. Binocular summation occurred only in far vision conditions (no defocus added). For near vision, binocular visual acuity closely followed the values of monocular visual acuity for the eye with the smaller aperture. CONCLUSIONS. The small-aperture effect to increase depth of focus in the human eye was successfully implemented in a binocular visual simulator. Although certain limitations exist, the small-aperture approach provided a simple but attractive solution to increase depth of focus in the human eye. (Invest Ophthalmol Vis Sci. 2011; 52:5273-5277) DOI: 10.1167/iovs.10-6436
引用
收藏
页码:5273 / 5277
页数:5
相关论文
共 50 条
  • [1] Optical modeling of a corneal inlay in real eyes to increase depth of focus: Optimum centration and residual defocus
    Tabernero, Juan
    Artal, Pablo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (02): : 270 - 277
  • [2] Evaluating the effect of corneal inlay implantation depth on visual outcomes and stability
    Lin, Ling
    Vilupuru, Srividhya
    Pepose, Jay Stuart
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [3] Comparison of binocular through-focus visual acuity with monovision and a small aperture inlay
    Schwarz, Christina
    Manzanera, Silvestre
    Prieto, Pedro M.
    Fernandez, Enrique J.
    Artal, Pablo
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (10): : 3355 - 3366
  • [4] Visual outcomes of binocular implantation of a new extended depth of focus intraocular lens
    Sinha, Rajesh
    Sahay, Pranita
    Saxena, Rohit
    Kalra, Nidhi
    Gupta, Vinay
    Titiyal, Jeewan S.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (10) : 2111 - 2116
  • [5] Depth of Focus Through Different Intraocular Lenses in Patients With Different Corneal Profiles Using Adaptive Optics Visual Simulation
    Ruiz-Alcocer, Javier
    Perez-Vives, Cari
    Madrid-Costa, David
    Garcia-Lazaro, Santiago
    Montes-Mico, Robert
    JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (06) : 406 - U42
  • [6] Visual simulation to customize depth of focus with new aspheric IOLs
    Angel Villegas, Eloy
    Ginis, Harilaos S.
    Hervella, Lucia
    Robles, Consuelo
    Prieto, Pedro
    Artal, Pablo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [7] Binocular depth processing in the ventral visual pathway
    Verhoef, Bram-Ernst
    Vogels, Rufin
    Janssen, Peter
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 2016, 371 (1697)
  • [8] The Evaluation of a New IOL with Extended Depth of Focus to Increase Visual Acuity for Intermediate Distance
    Fikret Ucar
    Servet Cetinkaya
    SN Comprehensive Clinical Medicine, 2021, 3 (11) : 2285 - 2291
  • [9] Aspheric lens to increase the depth of focus
    Vazquez-Villa, Alexis
    Delgado-Atencio, Jose A.
    Vazquez-Montiel, Sergio
    Castro-Ramos, Jorge
    Cunill-Rodriguez, Margarita
    OPTICS LETTERS, 2015, 40 (12) : 2842 - 2845
  • [10] Presbyopia. Corneal Inlay: Less flare, better visual acuity?
    Bitzer, Michaela
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2012, 229 (07) : 673 - 673