Impact of Axial Compression for the mMR Simultaneous PET-MR Scanner

被引:0
|
作者
Belzunce, Martin A. [1 ]
O'Doherty, Jim [1 ]
Reader, Andrew J. [1 ]
机构
[1] Kings Coll London, St Thomas Hosp, Div Imaging Sci & Biomed Engn, London, England
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In 3D PET an axial compression is often applied to reduce the data size and the computation times during image reconstruction. This compression scheme can achieve good results in the centre of the FOV. However, there is a loss in the spatial resolution at off-centre positions and this effect is increased in scanners with a larger FOV. This is the case for the Siemens Biograph mMR, which by default uses an axial compression of span 11. An assessment of the improvement in the spatial resolution that would be achieved in a reconstruction without axial compression, is necessary to evaluate if the additional computational burden is justified for routine image reconstruction. In this work, we present an implementation of the ordinary Poisson ordered subsets expectation maximization (OP-OSEM) algorithm without axial compression for the mMR, and evaluate its performance for span 1 and span 11. We show that an improvement of 3 mm FWHM (i.e. an improvement of 40%) can be achieved when span 11 compression is avoided and the source is at a distance greater than 100 mm from the centre of the FOV. In addition, the general image quality properties of the algorithm were evaluated with a NEMA image quality phantom acquisition and contrasted with its reconstruction via the STIR open source reconstruction software.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Practical issues and limitations of brain attenuation correction on a simultaneous PET-MR scanner
    Mackewn, J. E.
    Stirling, J.
    Jeljeli, S.
    Gould, S. M.
    Johnstone, R. I.
    Merida, I.
    Pike, L. C.
    McGinnity, C. G.
    Beck, K.
    Howes, O.
    Hammers, A.
    Marsden, P. K.
    EJNMMI PHYSICS, 2020, 7 (01)
  • [2] Practical issues and limitations of brain attenuation correction on a simultaneous PET-MR scanner
    J. E. Mackewn
    J. Stirling
    S. Jeljeli
    S-M. Gould
    R. I. Johnstone
    I. Merida
    L. C. Pike
    C. J. McGinnity
    K. Beck
    O. Howes
    A. Hammers
    P. K. Marsden
    EJNMMI Physics, 7
  • [3] Quantitative Simultaneous PET-MR Imaging
    Ouyang, Jinsong
    Petibon, Yoann
    Huang, Chuan
    Reese, Timothy G.
    Kolnick, Aleksandra L.
    El Fakhri, Georges
    MICRO- AND NANOTECHNOLOGY SENSORS, SYSTEMS, AND APPLICATIONS VI, 2014, 9083
  • [4] Time-invariant component- based normalization for a simultaneous PET-MR scanner
    Belzunce, M. A.
    Reader, A. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (09): : 3554 - 3571
  • [5] Initial Characterization of the SAFIR Prototype PET-MR Scanner
    Ritzer, Christian
    Becker, Robert
    Buck, Alfred
    Commichau, Volker
    Debus, Jan
    Djambazov, Lubomir
    Eleftheriou, Afroditi
    Fischer, Jannis
    Fischer, Peter
    Ito, Mikiko
    Khateri, Parisa
    Lustermann, Werner
    Ritzert, Michael
    Roser, Ulf
    Rudin, Markus
    Sacco, Ilaria
    Tsoumpas, Charalampos
    Warnock, Geoffrey
    Wyss, Matthias
    Zagozdzinska-Bochenek, Agnieszka
    Weber, Bruno
    Dissertori, Gunther
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2020, 4 (05) : 613 - 621
  • [6] Impact of MR-based PET motion correction on the quantification of PET kinetic parameters in simultaneous cardiac PET-MR
    Petibon, Yoann
    Ebrahimi, Behzad
    Reese, Timothy
    Guehl, Nicolas
    Normandin, Marc
    Alpert, Nathaniel
    El Fakhri, Georges
    Ouyang, Jinsong
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [7] Fast tagged MR acquisition for PET motion correction in simultaneous cardiac PET-MR
    Huang, Chuan
    Petibon, Yoann
    Ouyang, Jinsong
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [8] Assessment of motion correction strategies in simultaneous PET-MR
    Chun, Se Young
    Guerin, Bastien
    Cho, Sanghee
    Reese, Timothy
    Zhu, Xuping
    Ouyang, Jinsong
    Catana, Ciprian
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [9] ML and MAP PET reconstruction with MR-voxel sizes for simultaneous PET-MR
    Belzunce, Martin A.
    Mehranian, Abolfazl
    Bland, James
    Reader, Andrew J.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [10] MR-based motion compensation in simultaneous cardiac PET-MR
    Petibon, Yoann
    Ouyang, Jinsong
    Zhu, Xuping
    Reese, Timothy
    Dagher, Joseph
    Catana, Ciprian
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53