Embolization of ruptured intracranial aneurysms with detachable coils: case series

被引:2
|
作者
Lukic, Snezana [2 ]
Mijailovic, Milan [2 ]
Markovic, Zeljko [1 ]
Jankovic, Slobodan M. [3 ]
Nikolic, Radivoje [4 ]
机构
[1] Clin Ctr Serbia, Inst Radiol, Belgrade, Serbia
[2] Clin Ctr Kragujevac, Dept Neuroradiol, Kragujevac, Serbia
[3] Clin Ctr Kragujevac, Dept Clin Pharmacol, Kragujevac, Serbia
[4] Clin Ctr Kragujevac, Dept Neurosurg, Kragujevac, Serbia
关键词
Endovascular coiling; Intracranial aneurysm; Subarachnoid hemorrhage; ENDOVASCULAR TREATMENT; MANAGEMENT; HEADACHE;
D O I
10.1007/s11604-010-0519-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We present a series of patients with subarachnoid hemorrhage (SAH) from ruptured intracranial aneurysms who were treated with endovascular embolization by detachable coils. There were 108 patients with SAH treated with endovascular coiling. The efficacy of the endovascular coiling was estimated by initial postembolization angiography and by digital subtraction angiography after 6 months, using the following categories: complete occlusion of an aneurysm (98%-100%), nearcomplete occlusion (90%-98%), and incomplete occlusion (< 90%). In 42 (39%) patients the endovascular coiling was performed during the fi rst 72 h after SAH, and 48 (44%) patients had aneurysms < 10 mm in diameter. The most frequent location of ruptured aneurysms was the internal carotid artery (39 patients, 36%). Initially, complete occlusion of the aneurysm was achieved in 87 patients (81%), near-complete in 12 patients (11%), and incomplete in 9 patients (8%). After 6 months, complete occlusion of the aneurysm remained in 84 patients, nearcomplete in 12 patients, and incomplete in 6 patients; 6 patients were lost to follow-up. Endovascular coiling of ruptured intracranial aneurysms is an effi cient procedure that should be performed as soon as possible after detection of an SAH.
引用
收藏
页码:92 / 97
页数:6
相关论文
共 50 条
  • [21] Stability of ruptured intracranial aneurysms treated with detachable coils: is delayed follow-up angiography warranted?
    Tailor, Jignesh
    Goetz, Pablo
    Chandrashekar, Hoskote
    Stephen, Tina
    Schiariti, Marco
    Grieve, Joan
    Watkins, Lawrence
    Brew, Stefan
    Robertson, Fergus
    Kitchen, Neil
    BRITISH JOURNAL OF NEUROSURGERY, 2010, 24 (04) : 405 - 409
  • [22] Midterm prevention of rebleeding by Guglielmi detachable coils in ruptured intracranial aneurysms less than 10 mm
    Kawabe, T
    Tenjin, H
    Hayashi, Y
    Kakita, K
    Kubo, S
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2006, 108 (02) : 163 - 167
  • [23] Rupture of aneurysms during and after embolization with Guglielmi detachable coils
    Matsumaru, Y
    Sonobe, M
    Nakai, Y
    Takahashi, S
    Nose, T
    INTERVENTIONAL NEURORADIOLOGY, 2001, 7 : 83 - 87
  • [24] Measurement of volume embolization ratio on detachable coil treatment for intracranial aneurysms. The relationships between the volume embolization ratio and coil compaction on the intracranial aneurysms occluded using detachable coils was determined. Me
    Satoh, K
    Satomi, J
    Nakajima, N
    Matsubara, S
    Nagahiro, S
    STROKE, 2000, 31 (11) : 2769 - 2769
  • [25] Analysis of intraoperative complication of ruptured cerebral aneurysm with detachable coils embolization
    Xu Hao-wen
    Tan Song
    Song Bo
    Sun Shi-lei
    Xu Yu-ming
    LIFE SCIENCE JOURNAL-ACTA ZHENGZHOU UNIVERSITY OVERSEAS EDITION, 2011, 8 (03): : 543 - 546
  • [26] Endovascular treatment of ruptured intracranial aneurysms with detachable coils: Long-term clinical and serial angiographic results
    Sluzewski, M
    van Rooij, WJ
    Rinkel, GJE
    Wijnaida, D
    RADIOLOGY, 2003, 227 (03) : 720 - 724
  • [27] Evaluation of the stability of intracranial aneurysms occluded with Guglielmi detachable coils
    Tamatani, S
    Ito, Y
    Koike, T
    Abe, H
    Kumagai, T
    Takeuchi, S
    Tanaka, R
    INTERVENTIONAL NEURORADIOLOGY, 2001, 7 : 143 - 148
  • [28] ENDOVASCULAR TREATMENT OF INTRACRANIAL ANEURYSMS WITH ELECTRICALLY DETACHABLE PLATINUM COILS
    REUL, J
    SPETZGER, U
    FRICKE, C
    KONERT, T
    BERTALANFFY, H
    THRON, A
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1995, 120 (19) : 669 - 675
  • [29] INITIAL COMPARISON OF INTRACRANIAL ANEURYSM EMBOLIZATION WITH MECHANICAL DETACHABLE SPIRALS AND WITH GUGLIELMI DETACHABLE COILS
    王大明
    凌锋
    李萌
    王安顺
    蔡艺龄
    Chinese Medical Sciences Journal, 2003, (01) : 59 - 62
  • [30] Paediatric intracranial aneurysms: results of a surgical series and literature review of Guglielmi detachable coil embolization
    Lustgarten, L
    John, T
    Lopez, R
    Walzer, I
    Kerr, RSC
    Molyneux, AJ
    Byrne, JV
    JOURNAL OF CLINICAL NEUROSCIENCE, 1999, 6 (02) : 133 - 137