Objective: To report the incidence of intraoperative complications of coiling of ruptured cerebral aneurysms leading to permanent disability or death in a consecutive series of 341 patients and to identify risk factors for these events. Methods: Between January 2007 and May 2011, 341 consecutive patients with ruptured intracranial aneurysms were treated with detachable coils. Procedural complications of coils embolization leading to death or neurologic disability at the time of hospital discharge were recorded. For patients with procedural complications, odds ratios (OR) with corresponding 95% confidence intervals (CI) were calculated for the following patient and aneurysm characteristics: patient age and sex, use of a supporting balloon, aneurysm location, timing of treatment, clinical condition at the time of treatment, and aneurysm size. Results: Procedural complications occurred in 21 of 341 patients (6.16%; 95% CI, 4.2% to 8.1%), leading to death in 9 patients (procedural mortality, 2.6%; 95% CI, 1.6% to 4.2%) and to disability in 12 patients (procedural morbidity, 3.5%; 95% CI, 2.0% to 5.3%). There were 4 procedural ruptures and 17 thrombotic complications. The significant risk factors for the occurrence of procedural complications were use of supporting balloon (OR, 5.3; 95% CI, 2.3 to 16.1%) and stent (OR, 8.4; 95% CI, 4.1 to 20.5%). Conclusion: Procedural complication rate of coiling of ruptured aneurysms leading to disability or death is 6.16%. In this series, the use of a temporary supporting balloon and stent in the treatment of wide-necked aneurysms was the risk factors for the occurrence of complications. [Analysis of intraoperative complication of ruptured cerebral aneurysm with detachable coils embolization. Life Science Journal. 2011; 8(3):543-546] (ISSN: 1097-8135). http://www.lifesciencesite.com.
引用
收藏
页码:543 / 546
页数:4
相关论文
共 50 条
  • [1] An autopsy case of a ruptured cerebral aneurysm treated with interlocking detachable coils
    Otawara, Y
    Sugawara, T
    Seki, H
    Fujimura, M
    Tomichi, N
    NEUROLOGICAL SURGERY, 1997, 25 (09): : 829 - 833
  • [2] Durability of aneurysm embolization with matrix detachable coils
    Fiorella, D
    Albuquerque, FC
    McDougall, CG
    NEUROSURGERY, 2006, 58 (01) : 51 - 58
  • [3] COMPLICATION ANALYSIS OF INTRACRANIAL ANEURYSM EMBOLIZATION WITH CONTROLLABLE COILS
    王大明
    凌锋
    王安顺
    Chinese Medical Sciences Journal, 2004, (01) : 51 - 55
  • [4] Immunohistochemical analysis of a ruptured basilar top aneurysm autopsied 22 years after embolization with Guglielmi detachable coils (Reprinted)
    Yuki, Ichiro
    Spitzer, Daniel
    Guglielmi, Guido
    Duckwiler, Gary
    Fujimoto, Motoaki
    Takao, Hiroyuki
    Jahan, Reza
    Tateshima, Satoshi
    Murayama, Yuichi
    Vinuela, Fernando
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2015, 7 (08) : E29 - U15
  • [5] Durability of aneurysm embolization with matrix detachable coils - Comments
    Bendok, BR
    Rosenwasser, RH
    Sauvageau, E
    Hopkins, LN
    NEUROSURGERY, 2006, 58 (01) : 58 - 59
  • [6] Embolization of ruptured intracranial aneurysms with detachable coils: case series
    Lukic, Snezana
    Mijailovic, Milan
    Markovic, Zeljko
    Jankovic, Slobodan M.
    Nikolic, Radivoje
    JAPANESE JOURNAL OF RADIOLOGY, 2011, 29 (02) : 92 - 97
  • [7] Treatment of ruptured intracranial aneurysms by embolization with controlled detachable coils
    Brilstra, EH
    Rinkel, GJE
    NEUROLOGIST, 2002, 8 (01) : 35 - 40
  • [8] Embolization of ruptured intracranial aneurysms with detachable coils: case series
    Snežana Lukić
    Milan Mijailović
    Željko Marković
    Slobodan M. Janković
    Radivoje Nikolić
    Japanese Journal of Radiology, 2011, 29 : 92 - 97
  • [9] INITIAL COMPARISON OF INTRACRANIAL ANEURYSM EMBOLIZATION WITH MECHANICAL DETACHABLE SPIRALS AND WITH GUGLIELMI DETACHABLE COILS
    王大明
    凌锋
    李萌
    王安顺
    蔡艺龄
    Chinese Medical Sciences Journal, 2003, (01) : 59 - 62
  • [10] The impact of the neuroform stent on the durability of aneurysm embolization with matrix detachable coils
    Fiorella, D
    Albuquerque, FC
    McDougall, CG
    NEUROSURGERY, 2006, 58 (02) : 412 - 413