Size-specific dose estimates for pediatric head CT protocols based on the AAPM report TG-293

被引:3
|
作者
Sapignoli, Sonia [1 ]
Roggio, Antonella [1 ]
Boschini, Alessio [2 ]
Guida, Federica [1 ]
Merlo, Carlo [1 ]
Paiusco, Marta [1 ]
Zorz, Alessandra [1 ]
De Monte, Francesca [1 ,3 ]
机构
[1] IRCCS, Veneto Inst Oncol IOV, Med Phys Dept, Padua, Italy
[2] Med Phys Dept, Azienda ULSS2 Marca Trevigiana, Treviso, Italy
[3] IRCCS, Veneto Inst Oncol IOV, Med Phys Dept, Via Gattamelata 64, I-35128 Padua, Italy
关键词
SSDE; Head CT; Pediatric; Radiation dose tracking system; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; SUBSEQUENT RISK; PATTERNS; CHILDREN; TRENDS; SCAN;
D O I
10.1016/j.ejmp.2022.06.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To establish the Size Specific Dose Estimate (SSDE) typical values for pediatric head CT examinations based on the AAPM report TG-293; to provide a new stratification based on the water-equivalent diameter (Dw ), given that SSDE is related to the head size. Methods: 296 Head CT scans of pediatric patients collected using a dose monitoring software were retrospectively analysed. Typical values were derived stratifying data by age in three methods: the first proposed by the European Guidelines on Diagnostic Reference Levels for Pediatric Imaging (RP185), the second by the National Istisan Report 20/22 and a local one related to the clinical protocols (LStrata). For each scan, a self-developed Matlab routine calculated the water-equivalent diameter (Dw) and related SSDE values with the conversion factors fH16and fB16provided by the AAPM reports TG-293 and TG-204, respectively. Eventually, a Dwstratification was introduced starting from a measure of the lateral dimension of the head. Results: SSDE based on TG-204 overestimatesthe dose up to 12%. Four Dwgroups were identified thanks to the good correlation between the head lateral dimension andDw: Dw < 14 cm, 14 < Dw < 16 cm, 16 < Dw < 17 cm, Dw >= 17 cm. The Dw -stratified dosimetric indices present greater variability than those grouped by age because of the large variability of the size of the infant's head. Conclusions: The variability of the SSDE metric underlines that age-optimized protocols are not when size is considered.
引用
收藏
页码:26 / 30
页数:5
相关论文
共 50 条
  • [31] How accurate is size-specific dose estimate in pediatric body CT examinations?
    Karmazyn, Boaz
    Ai, Huisi
    Klahr, Paul
    Ouyang, Fangqian
    Jennings, S. Gregory
    PEDIATRIC RADIOLOGY, 2016, 46 (09) : 1234 - 1240
  • [32] How accurate is size-specific dose estimate in pediatric body CT examinations?
    Boaz Karmazyn
    Huisi Ai
    Paul Klahr
    Fangqian Ouyang
    S. Gregory Jennings
    Pediatric Radiology, 2016, 46 : 1234 - 1240
  • [33] A Segmentation-based Automated Calculation of Patient Size and Size-specific Dose Estimates in Pediatric Computed Tomography Scans
    Abdulkadir, Muhammad Kabir
    Osman, Noor Diyana
    Achuthan, Anusha
    Nasirudin, Radin A.
    Ahmad, Muhammad Zabidi
    Zain, Noor Hasyima Mat
    Shuaib, Ibrahim Lutfi
    JOURNAL OF MEDICAL PHYSICS, 2024, 49 (03) : 456 - 463
  • [34] An Investigation of Using a Single CT Image to Assess Size-Specific Dose Estimates (SSDE)
    Abuhaimed, A.
    Martin, C.
    MEDICAL PHYSICS, 2020, 47 (06) : E514 - E514
  • [35] A new approach to dose reference levels in pediatric CT: Age and size-specific dose estimation
    Rawashdeh, Mohammad
    Saade, Charbel
    Mousa, Dana S. Al
    Abdelrahman, Mostafa
    Kumar, Praveen
    McEntee, Mark
    RADIATION PHYSICS AND CHEMISTRY, 2023, 205
  • [36] Preliminary Study of Size-Specific Dose Estimates in Adult Abdomenal CT Examinations in Taiwan
    Tsai, H.
    Hwang, Y.
    Hu, Y.
    MEDICAL PHYSICS, 2015, 42 (06) : 3643 - 3643
  • [37] Size-Specific Dose Estimates (SSDE) for Pelvic CT Image Acquisitions: TG204 vs TG220 and a New Density Scaling Method
    Mihailidis, D.
    Tsapaki, V.
    MEDICAL PHYSICS, 2019, 46 (06) : E441 - E441
  • [38] Feasibility of size-specific organ-dose estimates based on water equivalent diameter for common head CT examinations: a Monte Carlo study
    Tahiri, M.
    Benameur, Y.
    Mkimel, M.
    El Baydaoui, R.
    Mesardi, M. R.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2023, 43 (02)
  • [39] Size-specific dose estimates (SSDE) for a prototype orthopeadic cone-beam CT system
    Richard, Samuel
    Packard, Nathan
    Yorkston, John
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [40] Attenuation-Based Size Adjusted, Scanner-Independent Organ Dose Estimates for Head CT Exams: TG 204 for Head CT
    McMillan, K.
    Bostani, M.
    Zankl, M.
    DeMarco, J.
    Cagnon, C.
    McNiff-Gray, M.
    MEDICAL PHYSICS, 2014, 41 (06) : 425 - 425