Purpose: To establish the Size Specific Dose Estimate (SSDE) typical values for pediatric head CT examinations based on the AAPM report TG-293; to provide a new stratification based on the water-equivalent diameter (Dw ), given that SSDE is related to the head size. Methods: 296 Head CT scans of pediatric patients collected using a dose monitoring software were retrospectively analysed. Typical values were derived stratifying data by age in three methods: the first proposed by the European Guidelines on Diagnostic Reference Levels for Pediatric Imaging (RP185), the second by the National Istisan Report 20/22 and a local one related to the clinical protocols (LStrata). For each scan, a self-developed Matlab routine calculated the water-equivalent diameter (Dw) and related SSDE values with the conversion factors fH16and fB16provided by the AAPM reports TG-293 and TG-204, respectively. Eventually, a Dwstratification was introduced starting from a measure of the lateral dimension of the head. Results: SSDE based on TG-204 overestimatesthe dose up to 12%. Four Dwgroups were identified thanks to the good correlation between the head lateral dimension andDw: Dw < 14 cm, 14 < Dw < 16 cm, 16 < Dw < 17 cm, Dw >= 17 cm. The Dw -stratified dosimetric indices present greater variability than those grouped by age because of the large variability of the size of the infant's head. Conclusions: The variability of the SSDE metric underlines that age-optimized protocols are not when size is considered.
引用
收藏
页码:26 / 30
页数:5
相关论文
共 50 条
  • [21] Size-specific optimization of CT protocols based on minimum detectability
    Zhang, Yakun
    Smitherman, Christopher
    Samei, Ehsan
    MEDICAL PHYSICS, 2017, 44 (04) : 1301 - 1311
  • [22] LOCAL DRLS FOR PAEDIATRIC CT EXAMINATIONS BASED ON SIZE-SPECIFIC DOSE ESTIMATES IN KERMANSHAH, IRAN
    Mohammadbeigi, Ahmad
    Khoshgard, Karim
    Haghparast, Abbas
    Eivazi, Mohammad Taghi
    RADIATION PROTECTION DOSIMETRY, 2019, 186 (04) : 496 - 506
  • [23] Size-specific dose estimations for pediatric chest, abdomen/pelvis and head CT scans with the use of GATE
    Kostou, Theodora
    Papadimitroulas, Panagiotis
    Papaconstadopoulos, Pavlos
    Devic, Slobodan
    Seuntjens, Jan
    Kagadis, George C.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 65 : 181 - 190
  • [24] Consideration of the usefulness of a size-specific dose estimate in pediatric CT examination
    Tsujiguchi, Takakiyo
    Obara, Hideki
    Ono, Shuichi
    Saito, Yoko
    Kashiwakura, Ikuo
    JOURNAL OF RADIATION RESEARCH, 2018, 59 (04) : 430 - 435
  • [25] Size-specific, scanner-independent organ dose estimates in contiguous axial and helical head CT examinations
    McMillan, Kyle
    Bostani, Maryam
    Cagnon, Chris
    Zankl, Maria
    Sepahdari, Ali R.
    McNitt-Gray, Michael
    MEDICAL PHYSICS, 2014, 41 (12)
  • [26] Considerations on the practical application of the size-specific dose estimation (SSDE) method of AAPM Report 204
    Noferini L.
    Fulcheri C.
    Taddeucci A.
    Bartolini M.
    Gori C.
    Radiological Physics and Technology, 2014, 7 (2) : 296 - 302
  • [27] Radiation dose in chest CT: Assessment of size-specific dose estimates based on water-equivalent correction
    Gabusi, M.
    Riccardi, L.
    Aliberti, C.
    Vio, S.
    Paiusco, M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (02): : 393 - 397
  • [28] USEFULNESS OF SIZE-SPECIFIC DOSE ESTIMATES IN PEDIATRIC COMPUTED TOMOGRAPHY: REVALIDATION OF LARGE-SCALE PEDIATRIC CT DOSE SURVEY DATA IN JAPAN
    Yamazaki, Daisuke
    Miyazaki, Osamu
    Takei, Yasutaka
    Matsubara, Kosuke
    Shinozaki, Masafumi
    Shimada, Yoshiya
    Suzuki, Shoichi
    Muramatsu, Yoshihisa
    RADIATION PROTECTION DOSIMETRY, 2018, 179 (03) : 254 - 262
  • [29] Size-Specific Dose Estimates for Evaluation of Individual Patient Dose in CT Protocol for Renal Colic
    Waszczuk, Lukasz A.
    Guzinski, Maciej
    Czarnecka, Anna
    Sasiadek, Marek J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (01) : 100 - 105
  • [30] Size-Specific Dose Estimates (SSDE) Factors for Head Scans of Different Imaging Systems
    Abuhaimed, A.
    Martin, C. J.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S759 - S759