Influence of high-pressure versus low-pressure balloon angioplasty on postinterventional luminal dimensions

被引:0
|
作者
Hering, D
Haude, M
Caspari, G
Baumgart, D
Erbel, R
机构
[1] UNIV ESSEN GESAMTHSCH KLIN,ZENTRUM INNERE MED,ABT KARDIOL,D-45122 ESSEN,GERMANY
[2] FREE UNIV BERLIN,KLIN BENJAMIN FRANKLIN,INNERE MED ABT,D-12200 BERLIN,GERMANY
来源
ZEITSCHRIFT FUR KARDIOLOGIE | 1996年 / 85卷 / 04期
关键词
angioplasty; recoil inflation pressure;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In this study, we examined whether percutaneous coronary angioplasty (PTCA) of native coronary arteries with high inflation pressure can improve the immediate postinterventional result in comparison to PTCA with nominal inflation pressure. Using quantitative coronary angiography, we analyzed the coronary angiograms of 24 patients who underwent PTCA with nominal inflation pressure (< 10 atm; group 1) and of 20 patients who underwent PTCA with high inflation pressure (greater than or equal to 10 atm; group 2). Only balloon catheters with little compliance were used. The following variables were recorded: 1) minimal luminal diameter (MLD), reference diameter and percent diameter stenosis before and after PTCA, 2) average balloon diameter during PTCA, 3) balloon/artery diameter ratio, 4) acute luminal gain (difference between MLD before and after PTCA), 5) nominal elastic recoil (difference between nominal balloon diameter and MLD after PTCA), 6) actual elastic recoil (difference between average balloon diameter during PTCA and MLD after PTCA). Nominal balloon diameter, reference diameter before and after PTCA and the balloon/artery diameter ratio were similar in both groups. Application of high inflation pressure resulted in a greater average balloon diameter. In group 2 (high inflation pressure), average balloon diameter amounted to 94 a 12% of nominal balloon diameter, whereas in group 1 (nominal inflation pressure), it reached only 84 +/- 9% of nominal balloon diameter. Actual elastic recoil was not different between the two groups. Nominal elastic recoil, however, was greater in the cohort which received PTCA with nominal inflation pressure (1.13 +/- 0.35 mm vs. 0.83 +/- 0.28 mm; p < 0.02). After use of high inflation pressure, acute postinterventional luminal gain was significantly increased (1.04 +/- 0.25 mm vs. 0.77 +/- 0.34 mm; p < 0.02) and the postinterventional percent diameter stenosis was significantly lower(12 +/- 10% vs. 24 +/- 13%; p < 0.05). Application of high inflation pressure improves the postinterventional result after PTCA because of a greater acute luminal gain. The stenotic coronary artery is expanded to a greater degree, and actual elastic recoil remains unchanged.
引用
收藏
页码:273 / 280
页数:10
相关论文
共 50 条
  • [21] VENOM DELIVERY OF SNAKES AS HIGH-PRESSURE AND LOW-PRESSURE SYSTEMS
    KARDONG, KV
    MURCIO, PAL
    AMERICAN ZOOLOGIST, 1991, 31 (05): : A112 - A112
  • [22] Comparison of cutting balloon versus high-pressure balloon angioplasty for resistant venous stenoses of native dialysis fistulas
    Wu, Chih-Cheng
    Lin, Ming-Chih
    Wen, Szu-Chi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 122 : 114 - 114
  • [23] Comparison of cutting balloon versus high-pressure balloon angioplasty for resistant venous stenoses of native hemodialysis fistulas
    Wu, Chih-Cheng
    Lin, Ming-Chih
    Pu, Shih-Yun
    Tsai, Kuei-Chin
    Wen, Szu-Chi
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (06) : 877 - 883
  • [24] Influence of thermowells on accuracy of temperature measurements for flowing gases in low-pressure and high-pressure pipelines
    Nath, B
    Dietrich, H
    TEMPERATURE '98, 1998, 1379 : 269 - 274
  • [25] Low-pressure stenting after cutting balloon angioplasty: Early results.
    Matsushita, T
    Yamada, T
    Tani, T
    Yamakami, S
    Iwata, K
    Murakami, Y
    Tsuda, M
    Okamoto, M
    Toyama, J
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (6A): : 60P - 60P
  • [26] HIGH-PRESSURE PRECIPITATION CHROMATOGRAPHY WITH GRADIENT GENERATION IN THE LOW-PRESSURE PART
    GLOCKNER, G
    ILCHMANN, D
    ACTA POLYMERICA, 1984, 35 (07) : 508 - 510
  • [27] CALCULATION OF A HIGH-PRESSURE EQUATION OF STATE FROM LOW-PRESSURE PROPERTIES
    BARTON, MA
    STACEY, FD
    PHYSICS OF THE EARTH AND PLANETARY INTERIORS, 1989, 56 (3-4) : 311 - 315
  • [28] Electronic structure of low-pressure and high-pressure phases of silicon disulfide
    D. I. Bletskan
    V. V. Vakulchak
    K. E. Glukhov
    Applied Physics A, 2014, 117 : 1499 - 1514
  • [29] Electronic structure of low-pressure and high-pressure phases of silicon disulfide
    Bletskan, D. I.
    Vakulchak, V. V.
    Glukhov, K. E.
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2014, 117 (03): : 1499 - 1514
  • [30] DILATATION AT HIGH-PRESSURE IN THE TRANS-LUMINAL ANGIOPLASTY OF HARD CORONARY STENOSES
    SIGWART, U
    GRBIC, M
    MORIN, D
    BANGOURA, A
    MARGARIA, F
    FISCHER, A
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1983, 113 (45) : 1689 - 1690