Influence of thermowells on accuracy of temperature measurements for flowing gases in low-pressure and high-pressure pipelines

被引:0
|
作者
Nath, B [1 ]
Dietrich, H [1 ]
机构
[1] Elster Prod GMBH, Abt Grundlagen Vorentwicklung, D-55252 Mainz, Germany
来源
TEMPERATURE '98 | 1998年 / 1379卷
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The following contribution deals with temperature measuring errors which may occur when recording the gas temperature within pipes that are equipped with thermowells. Using a simple one-dimensional heat flow model, the temperature difference between the gas and temperature sensor will be determined and confirmed by means of measuring results and CFD-simulations. In addition, measuring errors caused by the gas flow against the thermowell are analysed. A calculation example demonstrates how to check the thermodynamic design of a thermowell.
引用
收藏
页码:269 / 274
页数:4
相关论文
共 50 条
  • [1] MOBILITIES OF SLOW-ELECTRONS IN LOW-PRESSURE AND HIGH-PRESSURE GASES AND LIQUIDS
    CHRISTOPHOROU, LG
    INTERNATIONAL JOURNAL FOR RADIATION PHYSICS AND CHEMISTRY, 1975, 7 (2-3): : 205 - 221
  • [2] INFLUENCE OF LOW-PRESSURE AND HIGH-PRESSURE BAROREFLEXES ON VASOPRESSIN RELEASE IN HUMANS
    NORSK, P
    ACTA ENDOCRINOLOGICA, 1989, 121 : 1 - &
  • [3] HIGH-PRESSURE OR LOW-PRESSURE AIR GUNS
    ZIOLKOWSKI, A
    GEOPHYSICS, 1981, 46 (04) : 447 - 448
  • [4] LOW-PRESSURE WELLHEAD FOR HIGH-PRESSURE STIMULATION
    GARVIN, T
    JOURNAL OF PETROLEUM TECHNOLOGY, 1994, 46 (05): : 383 - 383
  • [5] LOW-PRESSURE AND HIGH-PRESSURE PYROLYSIS[1]
    EGSGAARD, H
    CARLSEN, L
    THERMOCHIMICA ACTA, 1988, 134 : 321 - 326
  • [6] Low-Pressure Electrochemical Synthesis of Complex High-Pressure
    Guan, Pin-Wen
    Sun, Ying
    Hemley, Russell J.
    Liu, Hanyu
    Ma, Yanming
    Viswanathan, Venkatasubramanian
    PHYSICAL REVIEW LETTERS, 2022, 128 (18)
  • [7] ARTERIOSCLEROSIS IN HIGH-PRESSURE AND LOW-PRESSURE CORONARY ARTERIES
    BURCH, GE
    DEPASQUALE, NP
    AMERICAN HEART JOURNAL, 1962, 63 (05) : 720 - &
  • [8] INFLUENCE OF LOW-PRESSURE AND HIGH-PRESSURE BARORECEPTORS ON PLASMA-RENIN ACTIVITY IN HUMANS
    MARK, AL
    ABBOUD, FM
    FITZ, AE
    AMERICAN JOURNAL OF PHYSIOLOGY, 1978, 235 (01): : H29 - H33
  • [9] Influence of high-pressure versus low-pressure balloon angioplasty on postinterventional luminal dimensions
    Hering, D
    Haude, M
    Caspari, G
    Baumgart, D
    Erbel, R
    ZEITSCHRIFT FUR KARDIOLOGIE, 1996, 85 (04): : 273 - 280
  • [10] HIGH-PRESSURE VERSUS LOW-PRESSURE ELECTROMAGNETIC EXTRACORPOREAL LITHOTRIPSY
    WIELAND, WF
    ROESSLER, W
    JOURNAL OF UROLOGY, 1994, 151 (06): : 1657 - 1657